Sign In
Upload
Manuals
Brands
dunphy Manuals
Burner
TD
dunphy TD Manuals
Manuals and User Guides for dunphy TD. We have
1
dunphy TD manual available for free PDF download: Operating Manual
dunphy TD Operating Manual (165 pages)
DUAL FUEL BURNERS
Brand:
dunphy
| Category:
Burner
| Size: 10 MB
Table of Contents
Table of Contents
4
1 General Information
7
General
7
Working Parameters
7
Fuels
7
Fuel Tanks
8
Filtration
8
Ring Main Pumps
8
Pipe Runs
8
Burner Connection
8
Burner Filtration
8
Pressure Regulation
8
Oil Line Connections
9
Burner Construction
9
Burner Details and Power Curve
12
General Arrangement Details
13
High Low/Modulating Burners on Gas, High Low on Oil
13
Electronic Modulation Burners (M RT)
14
TD10-415 Multi - Fuel Low Nox Burner General Arrangement
16
TD420 Multi - Fuel Low Nox Burner General Arrangement
17
TAD420 Multi - Fuel Low Nox Burner General Arrangement
18
2 Installation
19
Burner Mounting
19
Gas Valve Mounting
20
Burner Fitted with Unibloc
20
Burner Fitted with Siemens VGD40 Gas Valve
22
Fuel Oil Installations
23
Pump Connections
23
Pump Priming
23
Gas Installation
24
Electrical Connections
24
Inverter Connection
24
Ventilation Requirements
24
3 Combustion Head Settings
26
High / Low Burners
27
Modulating Burners
28
Modulating TD410 Burners Fitted with Low Nox Multi-Pipe Gas Head
29
Modulating TD415-420 Burners Fitted with Low Nox Multi-Pipe Gas Head
31
Modulating TD410 Burners Fitted with Low Nox Multi-Pipe Gas Head & Multi-Oil
33
Modulating TD415-420 Burners Fitted with Low Nox Multi-Pipe Gas Head & Multi-Oil
35
Modulating Burners Fitted with Bio - Gas Head
37
Nozzle Adjustment
38
Gas Head
38
Multipipe Gas Nozzle Adjustment
38
4 Adjustments and Operating Principles
39
High/Low Burners (HL)
39
High / Low Gas
39
High / Low Oil
40
Pneumatic Modulating Burners (M and M-Sc) on Gas, High / Low on Oil
42
Electronic Modulation Burners (M RT)
42
Oil Operating System Modulating Burners ART 114 and ART 1400 Nozzles
43
ART114 Burner Gun
44
ART 1400 Burner Gun
44
Oil Operating System Modulating Burners ART 106 Nozzle
46
Oil Operating System Modulating Burners Multi-Oil Nozzles
48
Oil Operating System High/Low Burners Multi-Oil Nozzles
49
Oil Operating System Air / Steam Atomising
50
Fuel Pumps and Motors
51
5 Operation & User Interface
52
The Display / Keypad
52
Start -Up Sequence
53
Modulation
55
Normal Mode
55
Local Mode
55
Non-Volatile Lockout
55
Ratiotronic 6000 Inverter Interface Additional Information
56
Post Purge Operation
56
Emergency Stop
57
6 Component Setup Parameters
58
Ratiotronic 6000
58
Danfoss VLT FC 102
64
RWF 40.000A97 Default Burner Settings
66
7 Commissioning
67
Basic Settings
67
Start Gas Heat Input
68
Pre-Commissioning
69
Commissioning - High Low and Pneumatic Modulation Burners - Firing on Gas
70
Dry Run
70
Check for Leaks through the Automatic Gas Valve
70
Check Rotation of Burner Fan Motor
70
Check for Correct Control Sequence
70
Firing the Burner
71
Combustion Values and Results
71
Adjustment of Gas Proving Pressure Switch
72
Oil Firing
72
Setting the Firing Rate, High / Low Oil Burners
72
Electronic Modulating Burners
75
Gas Butterfly Valve
75
Oil Metering Valve
75
Adjustment of Air Pressure Proving Switch
75
Ratiotronic Programming
76
Setting the Servo Motors
76
Burner Commissioning
76
Combustion Values and Results
76
8 Burner Maintenance Schedule
77
Opening the Burner
77
Minor Maintenance
78
Major Maintenance
78
Dismantling and Re-Assembly of Burners
79
9 Faults and Fault Finding
81
Ratiotronic 6000/6006
81
10 Useful Information
82
11 Exploded Diagram & Spare Parts List
85
Modulating Oil Modulating Gas Setup
85
Modulating Oil Modulating Gas with DH2 Pump (TD420 Only)
90
High Low Oil High Low Gas Setup (TD410 Only)
94
Modulating Gas High Low Oil Setup (TD410 Only)
99
Multi-Oil Multi-Gas Exploded Diagram
104
TD410 Low Nox Combustion Head Assembly
109
TD415-420 Low Nox Combustion Head Assembly
109
TD410 Combustion Head Assembly
110
TD415-420 Combustion Head Assembly
110
DN65 Unibloc
111
DN80 Unibloc
111
DN100 Unibloc
111
VGD40.65 Assembly for Pneumatic Modulating and High Low Burners
112
VGD40.80 Assembly for Pneumatic Modulating and High Low Burners
112
VGD40.100 Assembly for Pneumatic Modulating and High Low Burners
113
VGD40.65 Assembly for Electronic Modulating Burners
113
VGD40.80 Assembly for Electronic Modulating Burners
114
VGD40.100 Assembly for Electronic Modulating Burners
114
12 Component Information
115
LFL1.333 Burner Control Box
115
RWF 40 Burner Temperature Controller
123
Unibloc
128
Unibloc General Arrangements
128
65Mm Ratiotronic Unibloc Exploded Diagram and Parts List
130
65Mm Ratiotronic Unibloc with Pilot Exploded Diagrams and Parts List
131
80Mm Ratiotronic Unibloc Exploded Diagrams and Parts List
133
80Mm Ratiotronic Unibloc with Pilot Exploded Diagrams and Parts List
134
100Mm Ratiotronic Unibloc Exploded Diagrams and Parts List
136
100Mm Ratiotronic Unibloc with Pilot Exploded Diagrams and Parts List
137
Butterfly Gas Valve
139
General Arrangement
139
Exploded Diagram
140
Siemens VGD20 and VGD40 Gas Valve Blocks
141
Siemens SKP Actuators
145
VPS 504 Valve Proving System
151
Variotronic VT Oil Metering Valve
154
General Description
154
Construction
154
Valve Maintenance
154
Changing Seals
154
Adjustment of the Valve
155
Installation of the Valve
155
Valve Drive
155
Exploded Diagram
156
DH Series Pump
157
Pressure Regulation
158
Technical Data Summary
159
Installation Operation Maintenance
160
Fault Finding
161
Oil Flow Diagrams
162
Advertisement
Advertisement
Related Products
dunphy TAD4
dunphy Categories
Burner
More dunphy Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL