Manuals and User Guides for Drawell CIC-D100. We have
1
Drawell CIC-D100 manual available for free PDF download: User Manual
Drawell CIC-D100 User Manual (76 pages)
Ion Chromatograph
Brand:
Drawell
| Category:
Laboratory Equipment
| Size: 4 MB
Table of Contents
Table of Contents
3
Introduction
6
Instrument Introduction
12
Front Panel of the Instrument
12
Top Cover of the Instrument
13
Component Panel of the Instrument
13
Rear Panel of the Instrument
15
Instrument Components
16
Infusion Pump
16
Pressure Sensor
16
Exhaust Valve
16
Injection Valve
17
Column Heater
17
Conductivity Cell
18
Ampere Detector (Optional)
18
Suppressor
20
Eluent Generator (Optional)
21
Schematic Diagram of System Flow Path
24
Working Software
26
Kilospectrum Workstation
26
Reverse Control Software
26
Interface Menu Function
27
Interface Button Function
37
Instrument Operation and Maintenance
42
Start-Up
42
Water Quality Requirements
43
Checking All Connections
43
Balance System
43
Preparation of Samples
44
Selection and Preservation of Samples
44
Sample Pretreatment
44
Dilution of Samples
45
Injection and Analysis of Samples
45
Manual Injection
45
Automatic Sampler Injection
46
Maintenance
46
Check at any Time
46
Weekly Check
47
Regular Check
47
Common Faults and Troubleshooting
48
Pump Pressure Fluctuation
48
Frequent Overpressure
48
Large Baseline Noise
49
Large Baseline Drift
50
Too High Background Value
50
Low Response Value
50
Abnormal Suppressor Current
51
No Peak
51
Peak Tailing
51
Poor Degree of Separation
52
Poor Repeatability
52
Poor Linearity
53
There Are Bubbles in Infusion Pump
53
Handling of Abnormal Instrument Control
54
Maintenance
55
Removal of Blocking Units
55
Replacement of Pipelines and Joints
55
Replacement and Cleaning of the Check Valve
56
Steps of Cleaning Check Valve
56
Replacement of Check Valve
57
Replacement of Sealing Ring or Plunger Rod
57
Replacement of Conductivity Cell
58
Replacement of Amperometric Detection Cell Gasket
59
Replacement Reference Electrode
60
Replacement of the Suppressor
60
Replacement of the Power Fuse
61
Replacement of the Eluent Generator Storage Tank
62
Replacement of Capture Column
64
Norms
65
Electrical Correlation
65
Physical Correlation
65
Environmental Correlation
65
Installation
66
Equipment Requirements
66
Unpacking
66
Installation Software
67
Connecting the Instrument to Computer
67
Connecting the Automatic Sampler to the Instrument (Optional)
67
Steps for Connecting SHA-1 to Instrument Trigger Line
68
Steps for Connecting SHA-11D to Instrument Trigger Line
68
Steps for Connecting SHA-15 Automatic Sampler to Trigger Line of the Instrument
69
Steps for Connecting AS-11 to Trigger Line of the Instrument
70
Connecting Power Cord
71
Installation of Chromatographic Column and Suppressor
71
Installation of Chromatographic Column
71
Installation of Suppressor
72
Connecting Waste Liquid Pipes
72
Installation of Waste Liquid Pipes
73
Installation of Eluent Bottle
73
Flushing Pump
74
Flushing Pump Head
74
Flushing Eluent Pipeline
74
System Balance
75
Backpressure Requirement of Eluent Storage Tank
75
Confirmation of Operation Status
76
Pressurization of Eluent Bottle (Optional)
76
Advertisement
Advertisement
Related Products
Drawell 96T
Drawell B Series
Drawell B104 LED
Drawell B203 LED
Drawell B204 LED
Drawell Categories
Laboratory Equipment
Measuring Instruments
Scales
Accessories
Microscope
More Drawell Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL