Sign In
Upload
Manuals
Brands
Detcon Manuals
Security System
X40-32-N4X
Detcon X40-32-N4X Manuals
Manuals and User Guides for Detcon X40-32-N4X. We have
2
Detcon X40-32-N4X manuals available for free PDF download: Operator's Installation And Instruction Manual
Detcon X40-32-N4X Operator's Installation And Instruction Manual (71 pages)
Integrated Alarm and Control System
Brand:
Detcon
| Category:
Security System
| Size: 2.8 MB
Table of Contents
Table of Contents
3
List of Tables
5
1 Introduction
7
Features
7
Figure 1 Model X40-N4X Controller
7
LCD Main Display Function
8
Modbus™ Communication
8
Secure Digital Card (SD Card)
8
I/O Modules and Connections
8
Enclosure Types
10
Alarms and Fault Condition
11
System Operation
12
Operator Interface
13
Figure 2 Menu Flow Chart
13
Figure 3 Magnetic Programming Tool
14
Figure 4 Front Panel User Interface
14
Front Panel User Interface
14
Magnetic Programming Tool
14
Main Display Functions
15
Sensor Group
15
Transceiver Group
15
Rl4/Alarm Stations Group
16
Group
16
Menu Function
16
Optional Remote Alarm Reset/Acknowledge Switch
17
Wireless Option
18
Figure 5 Radio Module
18
2 Installation
19
Safety Guidelines
19
N1P and N1R Enclosure Installation
19
Figure 6 N1P Controller Mounting and Dimensional View
20
Figure 7 N1P RS-485 Port Connections
21
N4X Enclosure Installation
22
Figure 8 X40-08-N4X Controller Mounting and Dimensional View
22
Figure 9 X40-32-N4X Controller Mounting and Dimensional View
23
Figure 10 N4X Protective Earth Connector
24
Figure 11 Display Wiring
24
Figure 12 Cable Entry Points
24
Figure 13 N4X AC/DC Inputs
25
Figure 14 N4X RS-485 Master Port Connections
25
Figure 15 N4X RS-485 Slave Port Connections
26
Figure 16 N4X Antenna Connector
26
N7 Enclosure Installation
27
Figure 17 N7 Controller Mounting and Dimensional View
27
Figure 18 N7 Controller PCA
28
Figure 19 N7 Controller Assembly W/Mounting Plate
28
Figure 20 N7 AC/DC Converter Board Wiring
29
Figure 21 N7 DC Power Wiring
30
NEMA7 Units with RXT-320 Transceiver
30
Figure 22 Typical NEMA7 with Transceiver
31
Figure 23 Model 100 Terminal Board
31
Table 1 X40 Model 100 Terminal Board Connector Plugs
31
3 I/O Connections
34
I/O Module Installation
34
Analog 4-20Ma Sensor Inputs (DA-4)
35
Dry Contact Inputs (DI-4)
36
Analog 4-20Ma Outputs (AO-4)
37
Alarm Relay Outputs (RL-4)
39
RS-485 Serial Gas Sensors
40
Wireless RXT-320 Modbus™ Devices and CXT-320 Sensors
41
RXT-320 Wireless Transceiver Analog Inputs
41
Smartwireless® CXT Sentinel Slave Controller
42
Smartwireless® CX Sentinel Sensor Station
44
General Installation Wiring Notes
45
Initial Start-Up
45
4 Secure Digital Card
46
5 System Configuration
47
X40 Controller Setup
47
Menu Functions
47
Auto Configure System
47
Setup Channel Data
48
Set Channel Alarms
49
Set Relay (Alarm) Functions
50
Inhibit and Alarm Test Mode
51
System Diagnostics
51
Time and Date
52
View TWA and Peak
53
Table 4 X40 Register Map
54
6 Modbus™ Slave Communications Port
54
Modbus™ Register Map
54
7 Remote Alarm Reset/Acknowledge Switch Installation
56
8 Troubleshooting Guide
57
Replacement of the Display PCA in NEM7 Units
57
Replacement of the NEMA 4 Drop-In Display Assembly
58
9 Customer Support and Service Policy
59
10 Warranty Notice
60
11 Appendix
61
Specifications
61
Hexadecimal Table
62
Utilities
63
Set Channel Data
63
Set RF Silence and RF Sleep (Wireless Function Only)
65
Set Low Battery Alarms
65
Set Modbus™ Address
66
CXT Low Battery Threshold
66
Module Update Interval
66
Set COMM Baud Rates
66
Set Modbus™ Timeouts
67
Display Settings
67
Spare Parts and Wireless Accessories
69
Revision Log
70
Advertisement
Detcon X40-32-N4X Operator's Installation And Instruction Manual (62 pages)
Integrated Alarm and Control System
Brand:
Detcon
| Category:
Control Systems
| Size: 1.2 MB
Table of Contents
Table of Contents
3
Introduction
7
Features
7
Figure 1 Model X40-N4X Controller
7
LCD Main Display Function
8
Modbus™ Communication
8
Secure Digital Card (SD Card)
8
I/O Modules and Connections
8
Enclosure Types
10
Alarms and Fault Condition
11
System Operation
12
Operator Interface
13
Figure 2 Menu Flow Chart
13
Magnetic Programming Tool
14
Front Panel User Interface
14
Figure 3 Magnetic Programming Tool
14
Figure 4 Front Panel User Interface
14
Main Display Functions
15
Sensor Group
15
Transceiver Group
15
Rl4/Alarm Stations Group
16
Group
16
Menu Function
16
Optional Remote Alarm Reset/Acknowledge Switch
17
Wireless Option
17
Installation
19
Safety Guidelines
19
N1P Enclosure Installation
19
Figure 5 N1P Controller Mounting and Dimensional View
19
Figure 6 N1P AC/DC Inputs
20
Figure 7 N1P RS-485 Port Connections
20
N4X Enclosure Installation
21
Figure 8 X40-08-N4X Controller Mounting and Dimensional View
21
Figure 9 X40-32-N4X Controller Mounting and Dimensional View
22
Figure 10 N4X Protective Earth Connector
22
Figure 11 N4X AC/DC Inputs
23
Figure 12 N4X RS-485 Master Port Connections
23
Figure 13 N4X RS-485 Slave Port Connections
24
Figure 14 N4X Antenna Connector
24
N7 Enclosure Installation
25
Figure 15 N7 Controller Mounting and Dimensional View
25
Figure 16 N7 Controller Assembly W/Mounting Plate
26
Figure 17 N7 Controller PCA
26
Figure 18 N7 AC/DC Converter Board Wiring
27
Wireless Radio Module Wiring
28
Figure 19 N7 DC Power Wiring
28
Figure 20 Wireless Radio Module Assembly for X40 Controller
28
Figure 21 Wireless 320 Transceiver Assembly W/Mounting Plate Dimensions
29
Figure 22 Model 100 Terminal Board to X40 Controller Wiring
29
Model 100 Terminal Board
30
Figure 23 Model 100 Terminal Board
30
Table 1 X40 Model 100 Terminal Board Connector Plugs
30
Transient Protection Board
31
Figure 24 Model 100 Terminal Board Rotary Switches
31
Figure 25 Wiring Diagram to the Master
31
Figure 26 Wiring Diagram to the Slave
32
I/O Connection Installation
33
Figure 27 I/O Module Installation
33
Analog 4-20Ma Sensor Inputs (DA-4)
34
Figure 28 Model DA-4 4-20Ma Input Module and 4-20Ma Gas Sensor Connections
34
Figure 29 Model DA-4 4-20Ma Input Module and 4-20Ma Gas Sensors
34
Dry Contact Inputs (DI-4)
35
Figure 30 Model DI-4 Contact Input Module
35
Analog 4-20Ma Outputs (AO-4)
36
Figure 31 Model AO-4 4-20Ma Output Module
36
Table 2 AO-4 Modbus™ Addresses
37
Alarm Relay Outputs (RL-4)
38
Figure 32 Model RL-4 Relay Output Module
38
Table 3 RL-4 Relay Modbus™ Addresses
39
Serial Output Gas Sensors (RS-485)
40
Figure 33 Modbus™ Gas Sensor Connections
40
General Installation Wiring Notes
41
Initial Start-Up
41
Secure Digital Card
42
System Configuration
42
X40 Controller Setup
42
Menu Functions
42
Auto Configure System
43
Set Channel Alarms
44
Set Relay (Alarm) Functions
45
Inhibit and Alarm Test Mode
45
System Diagnostics
46
Time and Date
47
View TWA and Peak
48
Modbus™ Communications
48
Modbus™ Register Map
49
Table 4 X40 Register Map
49
Remote Alarm Reset/Acknowledge Switch Installation
50
Figure 34 N1P & N4X Remote Switch Input
50
Figure 35 N7 Remote Switch Input
50
Troubleshooting Guide
51
Customer Support and Service Policy
51
Warranty Notice
52
Appendix
53
Specifications
53
Utilities
54
Set Channel Data
54
Set RF Silence and RF Sleep (Wireless Function Only)
56
Set Low Battery Alarms
56
Set Modbus™ Address
57
CXT Low Battery Threshold
57
Module Update Interval
57
Set COMM Baud Rates
58
Set Modbus Timeouts
58
Display Settings
59
Spare Parts and Wireless Accessories
60
Revision Log
61
Advertisement
Related Products
Detcon X40-32-N1P
Detcon X40-32-N7
Detcon X40-08-N4X
Detcon 240
Detcon C1D2
Detcon SW-AV2-N4
Detcon Categories
Accessories
Security System
Measuring Instruments
Control Systems
Gas Detectors
More Detcon Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL