Sign In
Upload
Manuals
Brands
DEC Manuals
Control Unit
KA694
DEC KA694 CPU System Maintenance Manuals
Manuals and User Guides for DEC KA694 CPU System Maintenance. We have
1
DEC KA694 CPU System Maintenance manual available for free PDF download: System Maintenance
DEC KA694 System Maintenance (358 pages)
CPU
Brand:
DEC
| Category:
Control Unit
| Size: 1 MB
Table of Contents
Table of Contents
3
Preface
15
1 System Maintenance Strategy
17
Service Delivery Methodology
17
Product Service Tools and Utilities
18
Information Services
21
Field Feedback
22
2 CPU System Overview
23
CPU Module Features
24
KA681/KA691/KA692/KA694 CPU Module Component Side
25
KA681/KA691/KA692/KA694 CPU Module Components
26
KA681/KA691/KA692/KA694 Kernel System Functional Diagram
27
MS690 Memory Modules
28
KA681/KA691/KA692/KA694 CPU Module Block Diagram
28
Optional) DSSI Daughter Board
29
Ratchet Handles for CPU and Memory Modules
29
Optional) DSSI Module Component Side
30
BA440 Enclosure Components
31
H3604 Console Module
31
Optional) DSSI Bus Daughter Board Components
31
H3604 Console Module (Front)
32
H3604 Console Module Controls and Indicators
33
H3604 Console Module (Back)
35
H3604 Console Module (Back)
36
System Control Panel (SCP)
38
System Control Panel
38
System Control Panel Controls and Indicators
39
BA440 Backplane
41
Power Supply
42
H7874 Power Supply
42
H7874 Power Supply Switches, Controls, and Indicators
43
System Airflow
45
Fan Speed Control (FSC) Jumper Location
46
3 System Setup and Configuration
47
CPU and Memory Module Order
47
BA440 Module Order
47
Installing Add-On MS690 Memory Modules
48
General Module Order for Q-Bus Options
50
Memory Module Ratchet Handles
50
Recommended Module Order of Q-Bus Options
53
Optional) DSSI Ports Assignment
54
Mass Storage Options (Internal)
54
Storage Configuration Example
55
For DSSI Devices
55
System Expansion
56
Mass Storage Expanders
56
Q-Bus Expanders
57
Control Power Bus for Expanders
58
Sample Power Bus Configuration
58
Adding Options to the System Enclosure
59
VAX 4000 Model 500A/505A/600A/700A/705A Configuration Worksheet
60
Power Requirements
61
DSSI Vaxclusters
63
DSSI Cabling for a Generic Two-System DSSI Vaxcluster Configuration
64
DSSI Vaxcluster Configuration Rules
65
Two-System DSSI Vaxcluster
68
Expanded Two-System DSSI Vaxcluster
69
Firmware Commands and Utilities Used in System Configuration
70
Examining System Configuration
70
Using the CONFIGURE Command to Determine CSR Addresses for Q-Bus Modules
72
Setting and Examining Parameters for DSSI Devices
74
DSSI Device Parameters
75
How the Openvms Operating System Uses the DSSI Device Parameters
76
Openvms Operating System Requires Unique Unit Numbers
78
Sample DSSI Buses for an Expanded VAX 4000 Model 500A System
80
SHOW DSSI Display (Embedded DSSI)
81
Entering the DUP Driver Utility from Console Mode
82
SHOW UQSSP Display (KFQSA-Based DSSI)
82
Entering the DUP Driver Utility from the Openvms
84
Setting Allocation Class
85
Setting Unit Number
85
Setting a Unit Number for a Specified Device
86
Attaching a MSCP Unit Number Label to the Device Front Panel
87
Setting Node Name
88
Setting System ID
88
Exiting the DUP Driver Utility
89
Exiting the DUP Driver Utility for a Specified Device
90
SHOW DSSI Display
91
Write-Protecting an EF/RF ISE
92
Software Write-Protect for EF/RF-Series Ises
92
Hardware Write-Protect for EF/RF Ises
93
Setting Hardware Write-Protection through Firmware
95
Operating System
96
Setting System Parameters: Boot Defaults, Bootflags, Halt and Restart Action
97
Setting the Boot Default
97
Boot Devices Supported by the KA681/KA691/KA692/KA694
98
Setting Boot Flags
99
Virtual Memory Bootstrap (VMB) Boot Flags
99
Setting the Halt Action
100
Actions Taken on a Halt
101
4 System Initialization and Acceptance Testing (Normal Operation)
103
Basic Initialization Flow
103
Language Inquiry on Power-Up or Reset
104
Language Selection Menu
105
Power-On Self-Tests (POST)
106
Power-Up Tests for Kernel
106
Console Banner
107
LED Codes
108
Power-Up Tests for Q-Bus Options
109
Power-Up Tests for Mass Storage Devices
110
CPU ROM-Based Diagnostics
110
Diagnostic Tests
111
Test 9E
112
Scripts
115
Scripts Available to Customer Services
116
Basic Acceptance Test Procedure
117
Signature Field Values
119
Machine State on Power-Up
122
Main Memory Layout and State
122
Reserved Main Memory
123
PFN Bitmap
123
Memory Layout after Power-Up Diagnostics
123
Scatter/Gather Map
124
Firmware "Scratch Memory
124
Contents of Main Memory
124
Memory Controller Registers
125
On-Chip Cache
125
Translation Buffer
125
Halt-Protected Space
125
Operating System Bootstrap
125
Preparing for the Bootstrap
126
Primary Bootstrap Procedures (VMB)
128
Memory Layout Prior to VMB Entry
128
Memory Layout at VMB Exit
131
Device Dependent Secondary Bootstrap Procedures
132
Disk and Tape Bootstrap Procedure
132
PROM Bootstrap Procedure
133
Boot Block Format
133
MOP Ethernet Functions and Network Bootstrap Procedure
134
Network "Listening
135
Network Maintenance Operations Summary
137
Supported MOP Messages
138
Operating System Restart
141
MOP Multicast Addresses and Protocol Specifiers
141
Locating the RPB
142
Locating the Restart Parameter Block
142
5 System Troubleshooting and Diagnostics
143
Basic Troubleshooting Flow
143
Console Terminal/Console Module Problems
145
Power Supply Status Indicators
145
Product Fault Management and Symptom-Directed Diagnosis
146
General Exception and Interrupt Handling
146
Openvms Operating System Error Handling
147
Openvms Error Logging and Event Log Entry Format
149
Openvms Operating System Error Handler Entry Types
149
Event Log Entry Format
151
Machine Check Stack Frame Subpacket
152
Processor Register Subpacket
153
Memory Subpacket for ECC Memory Errors
154
Memory SBE Reduction Subpacket
154
CRD Entry Subpacket Header
155
Correctable Read Data (CRD) Entry
156
Openvms Operating System Event Record Translation
157
Interpreting CPU Faults Using ANALYZE/ERROR
158
Error Log Entry Indicating CPU Error
159
System
160
Interpreting Memory Faults Using ANALYZE/ERROR
161
Uncorrectable ECC Errors
161
Error Log Entry Indicating Uncorrectable ECC Error
163
System
164
Correctable ECC Errors
165
Memory for a Replaced Page
165
Error Log Entry Indicating Correctable ECC Error
168
Interpreting System Bus Faults Using ANALYZE/ERROR
170
Error Log Entry Indicating Q-Bus Error
171
Analyze/Error
172
Vaxsimplus and System-Initiated Call Logging (SICL) Support
174
Conditions that Trigger Vaxsimplus Notification and Updating
176
Trigger Flow for the Vaxsimplus Monitor
177
Five-Level Vaxsimplus Monitor Display
179
Levels of Vaxsimplus Monitor Screen Displays
180
Converting the SICL Service Request MEL File
181
Vaxsimplus Installation Tips
182
Vaxsimplus Postinstallation Tips
183
Repair Data for Returning Frus
185
Interpreting Power-On Self-Test and ROM-Based Diagnostic Failures
185
Sample Output with Errors
186
Machine Check Exception During Executive
187
Exception During Executive with no Parameters
188
Other Exceptions with Parameters, no Machine Check
188
KA681/KA691/KA692/KA694 Console Displays as Pointers to Frus
190
FE Utility
200
Overriding Halt Protection
201
Isolating Memory Failures
202
Testing DSSI Storage Devices
204
Running DRVTST
205
Using MOP Ethernet Functions to Isolate Failures
207
Interpreting User Environmental Test Package (UETP)
210
Openvms Failures
210
Interpreting UETP Output
211
UETP Log Files
211
Possible UETP Errors
212
Using Loopback Tests to Isolate Failures
213
H3604 Console Module Fuses
213
Testing the Console Port
214
H3604 Console Module Fuses
214
Embedded DSSI Loopback Testing
215
Embedded Ethernet Loopback Testing
217
Q-Bus Option Loopback Testing
218
Loopback Connectors for Common Devices
218
6 FEPROM Firmware Update
219
Preparing the Processor for a FEPROM Update
220
Firmware Update Utility Layout
220
Updating Firmware Via Ethernet
221
W4 Jumper Setting for Updating Firmware
221
Updating Firmware Via Tape
224
FEPROM Update Error Messages
225
A KA681/KA691/KA692/KA694 Firmware Commands
229
A.1 Console I/O Mode Control Characters
229
A.1.1 Command Syntax
230
Command Syntax
230
Console I/O Mode Control Characters
230
A.1.2 Address Specifiers
231
Console Numeric Expression Radix Specifiers
236
Address Specifiers
231
Console Symbolic Addresses
231
Symbolic Addresses
231
Console Radix Specifiers
236
Console Command Qualifiers
237
Console Command Keywords
238
Boot
239
Configure
239
Deposit
239
Examine
239
Find
239
Halt
239
Help
239
Initialize
239
Move
239
Next
239
A.2 Console Commands
241
A.2.2 Configure
243
A.2.3 Continue
245
A.2.5 Examine
246
A.2.6 Find
247
A.2.7 Halt
248
A.2.8 Help
249
A.2.9 Initialize
250
A.2.10 Move
251
A.2.11 Next
252
A.2.12 Repeat
254
Search
255
A.2.13 Search
255
Set
257
A.2.14 Set
257
Show
262
A.2.15 Show
262
Start
266
Test
266
A.2.16 Start
266
Unjam
267
X-Binary Load and Unload
267
A.2.18 Unjam
267
(Comment
269
A.2.20 ! (Comment)
269
Symbolic Addresses Used in any Address Space
236
B Address Assignments
271
KA681/KA691/KA692/KA694 General Local Address Space Map
271
KA681/KA691/KA692/KA694 Detailed Local Address Space Map
272
Processor Registers
277
External Internal Processor Registers
278
Global Q22-Bus Address Space Map
278
B.5 Processor Registers
279
Processor Registers
285
IPR Address Space Decoding
286
C ROM Partitioning
287
C.1 Firmware EPROM Layout
287
Firmware EPROM Layout
288
KA681/KA691/KA692/KA694 FEPROM Layout
288
SID: System Identification Register
289
System Identification Register
289
SIE : System Identification Extension
290
System Identification Extension
290
C–3 SIE : System Identification Extension (20040004)
290
Call-Back Entry Points
291
C.1.2.2 Cp$Msg_Out_Nolf_R4
292
C.1.2.3 Cp$Read_Wth_Prmpt_R4
293
Boot Information Pointers
294
System Identification Registers
289
Pr$_Sid (Ipr 62)
289
Sie (20040004
289
D Data Structures and Memory Layout
295
D.1 Halt Dispatch State Machine
295
Firmware State Transition Table
296
Halt Dispatch State Machine
296
Restart Parameter Block (RPB)
300
Restart Parameter Block Fields
300
VMB Argument List
304
VMB Argument List
305
F NVRAM Partitioning
317
KA681/KA691/KA692/KA694 SSC NVRAM Layout
317
F.1 SSC RAM Layout
317
SSC RAM Layout
318
Console Program Mailbox (CPMBX
318
NVR0 (20140400): Console Program Mailbox (CPMBX
318
Firmware Stack
319
Diagnostic State
319
F.1.3 Firmware Stack
319
USER Area
320
F.1.5 USER Area
320
G MOP Counters
321
MOP Counter Block
321
H Programming the KFQSA Adapter
331
Preferred KFQSA Switch Settings
331
I Error Messages
337
Machine Check Register Dump
337
HALT Messages
337
Halt Code Messages
338
I–1 HALT Messages
338
VMB Error Messages
339
VMB Error Messages
340
Console Error Messages
340
J Related Documents
343
Glossary
345
Index
349
Fans
351
Advertisement
Advertisement
Related Products
DEC KA681
DEC KA691
DEC KA692
DEC KA650-AA
DEC KB11-D
DEC KB11-A
DEC Categories
Desktop
Server
Printer
Touch terminals
Monitor
More DEC Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL