Sign In
Upload
Manuals
Brands
Control Data Manuals
Computer Hardware
CDC CYBER 860A
Control Data CDC CYBER 860A Manuals
Manuals and User Guides for Control Data CDC CYBER 860A. We have
1
Control Data CDC CYBER 860A manual available for free PDF download: Installation And Checkout Manual
Control Data CDC CYBER 860A Installation And Checkout Manual (384 pages)
COMPUTER SYSTEMS
Brand:
Control Data
| Category:
Computer Hardware
| Size: 8 MB
Table of Contents
Revision Record
2
Table of Contents
9
Introduction
13
Manual Sections
13
Dual CP
13
Use of Manual and Flowcharts
15
Preinstallation
21
Obtaining.special Tools and Equipment
21
Special Tools, Equipment, and
23
Cooling Unit
24
Preparing the Site for Preinstallation
27
Raised-Floor Installation
27
Air Conditioning Installation
27
Water Line Installations
27
Wall-Mounted Power Box Installations
28
M-G Set Installation and Local Testing
28
50/60-Hz and 400-Hz Power Distribution Installation
28
Telephone and Modem Installation
30
Inspecting the Site
31
Raised-Floor Inspection
31
Air Conditioning Inspection 2-Ll
31
Water Line Inspection
31
Power Inspection
31
Telephone and Modem Inspection
32
Checking Bill of Lading for Preinstallation Equipment
33
Uncrating, Checking for Damage, and Verifying Shipping Lists
34
Example of Preinstallation Shipping List
35
Installing Water Hose Assemblies, Manifolds, and Hoses
37
Place Water Cooling Unit Site Supply and Return Water Hose Assemblies
38
Place Water Supply and Return Manifolds, and Connect Water Cooling Unit Hoses
41
Water Manifolds and Hose Placements for 102-L/Min (27-Gal/Min) Unit
43
Water Manifolds and Hose Placements for 220-L/Min (58-Gal/Min) Unit
45
Checking SPM Preoperating Conditions
47
SPM Transformer Tl Connections
49
EPROM Location on SPM Control Board
51
SPM Switches Snl, SN2, and SN3
53
SPM Switches Snl, SN2, and SN3
55
Checking SPM Operation with M-G Set
56
System Power Monitor Switches
57
Placing SPM Cables
60
Installation Installer 1
63
Checking Bill of Lading
63
Uncrating, Checking for Damage, and Verifying Shipping Lists
63
Bolting Cabinets
63
Connecting Channel Cables to IOU
63
Water Treatment Ph Indicator Kit
65
Differential Pressure Gauge
65
Shipping List Example
69
Placing Cabinets
71
Cabinet Placements
73
Cabinet Bolting Methods
77
Cabinet Bolt Locations
79
Connect Channel Cables to NIO Cabinet
82
NIO Cable Connector Panel
83
Unit
85
NIO Channel Cable Connections
85
Connect Channel Cables to Optional CIO Cabinet
86
CIO Cable Connector Panel
95
CIO Channel Cable Connections
97
Connecting Water Hoses
98
Connect Water Hose Assemblies to Water Cooling Unit(S)
98
Connect Water Cooling Unit(S) to Water Manifolds
98
Connect Supply and Return Water Hoses to CP
98
Water Hose Connections in a
109
Water Hose Connections in a 220-L/Min (58-Gal/Min)
111
Site Water Hose Assembly Connections to Water
113
Water Manifold Hose Connections to Water
117
Supply and Return Hose
118
Supply and Return Water Hose
119
Connect Supply and Return Water Hoses to CM and IOU
122
Supply and Return Water Hose Connections to CM
123
Connecting Power and EMC Straps
125
Connect and Verify Power Cords to Interbay Power Panel
125
Connect Power Cord from 102-L/Min (27-Gal/Min) Unit to Power Receptacle
125
Connect Power Cord from 220-L/Min
125
Receptacle
126
Power Panel
128
Power Connections to 102-L/Min
131
Front View
135
Power Connections to 220-L/Min
135
Connect or Remove Electromagnetic Compatibility Straps
137
Preparing Water Cooling Unit(S)
141
Check Valves on 102-L/Min (27-Gal/Min) Unit, CP, and CM
141
Cooling Unit
142
Valve Locations on 102-L/Min
144
Bypass Valve on 102-L/Min
145
Supply and Return Hose Assemblies 3-Way Valves
147
Check Pump Rotation on 102-L/Min (27-Gal/Min) Unit
148
Pump Rotation Check on
149
Fill Water Tank on 102-L/Min (27-Gal/Min) Unit
151
Water Tank Filling on 102-L/Min (27-Gal/Min)
153
Water Treatment Ph Indicator
155
Bleed Air from 102-L/Min (27-Gal/Min) Unit
158
(27-Gal/Min) Unit
158
Check Valves on 220-L/Min (58-Gal/Min) Unit, CP, and CM
160
Rear View
161
Valve Locations on 220-L/Min (58-Gal/Min) Unit
161
Check Pump Rotation on 220-L/Min (58-Gal/Min) Unit
164
Pump Rotation Check on 220-L/Min (58-Gal/Min) Unit
165
Fill Water Tank on 220-L/Min (58-Gal/Min) Unit
168
Water Tank Filling on 220-L/Min (58-Gal/Min) Unit
169
Water Tank Filling on 220-L/Min (58-Gal/Min) Unit
171
Sample Tubes
175
Bleed Air from 220-L/Min (58-Gal/Min) Unit
177
Air Bleed Valve on 220-L/Min (58-Gal/Min) Unit
177
220-L/Min (58-Gal/Min)
177
Adjust Water Flow Rates to CP, CH, and IOU
178
CP Column and CM Water Flow Meters and Valve Adjust Handles
179
Check Water Cooling Unit Temperature, Pressure, and Flow
182
Water Cooling Unit Temperature, Pressure, and Flow Rate Meters
183
Check Site Water Flow Rate
184
Water Cooling Unit Mixing Valve Indicator
191
Bleed Air from CP
196
CP Columns Air Bleed Valve Locations
197
Bleed Air from IOU
200
Apply M-G Set Power from SPM
203
Apply Power and Adjust Voltages for IOU Optional CIO Cabinet
203
Apply Power and Adjust Voltages for CP-0 and Optional
203
Apply Power and Adjust Voltages for CM
203
SPM Switches Snl, SN2, and SN3
205
System Power Monitor Switches and Display Panel
207
IOU Power Controls and Adjustments
209
Power Panel
210
Apply Power
211
IOU Power Controls and Adjustments
213
IOU Power Controls and Adjustments
215
IOU Power Controls and Adjustments
217
IOU Power Controls and Adjustments
219
IOU Low-Temperature Sensor Assembly
221
CP Power Controls and Adjustments
223
CP Power Controls and Adjustments
225
CP Power Controls and Adjustments
227
CM Power Controls and Adjustments
229
CM Power Controls and Adjustments
231
CM Power Controls and Adjustments
233
Rechecking Water Flow Rates
235
Installation Installer 2
237
Uncrating, Checking for Damage, and Verifying Shipping Lists
237
Bolting Cabinets
237
Installing Display Terminal or Station
237
Shipping List Example for
241
Cabinet Bolt Locations
251
Connect CC634-B Display Terminal
253
Connect Cc545-C, D, E, or Fdisplay Station
254
Display Station Signal
255
Connecting CP Cables
257
Connect CP-0 and CP-1 Cables to IOU Backpanel a
258
Cables to IOU Backpanel a
259
Cable Connections
259
IOU Backpanel a Cable Connections
261
Cables to IOU Backpanel a
263
Connect CP-0 CMC Cables to CM
264
Cable Connections
265
CMC to CM Cable
265
To CM
265
CP-0 to CM Cable Connections
266
And CP-1 Long and Short
267
Connect CP-1 Local Memory Cables
269
Local Memory Cables to
270
Connect CM Cable to CP-1 ZIF Cage
271
Connect Clock Cables
272
CMC
273
Connect Fault-Sense Cables to CM Multiplexer Board
275
Connect IOU CIO Cables to NIO Connector Panel
278
Connect System Power Monitor Cables
280
SPM Cable Connections to Central Computer
281
SPM Cable Connections to
283
SPM Cable Connections to Water
285
Checking Cabinet Initial Conditions
287
Verify or Change Blower Motor Connections in CM and IOU Cabinets
288
Verify or Change Motor and Transformer Connections in 102-L/Min (27-Gal/Min) Unit
292
Transformer Connections in 102-L/Min (27-Gal/Min)
293
Verify or Change Motor and Transformer Connections in 220-L/Min (58-Gal/Min) Unit
296
Verify or Change Cabinet Switches
300
Multiplexer Board DIP Switches in CP and CM Cabinets
301
Applying System Power
303
Apply M-G Set Power from SPM
303
Apply Power and Adjust Voltages for IOU NIO Cabinet
303
SPM Controls and Display Panel
307
IOU Power Controls and
309
Power Panel
310
IOU Power Controls and Adjustments
311
IOU Power Controls and Adjustments
313
IOU Low-Temperature Sensor Assembly
315
Apply Power and Adjust Voltages for IOU CIO Cabinet
316
IOU Power Controls and
317
IOU Low-Temperature Sensor Assembly
321
Apply Power and Adjust Voltages for CP-0 and Optional
322
CP Power Controls and Adjustments
323
CP Power Controls and Adjustments
325
CP Power Controls and Adjustments
327
CM Power Controls and Adjustments
329
CM Power Controls and Adjustments
331
Apply Power and Adjust Voltages for CM
332
CM Power Controls and Adjustments
333
Rechecking Water Flow Rates
335
Installation Electrician
337
Connect 50/60-Hz and 400-Hz Power to Interbay Power Panel
337
Connecting Power to Display Station
337
Connecting Power to Water Cooling Unit
337
50/60-Hz and 400-Hz Power
342
Power Connections to Display Station
343
Connect Power to 102-L/Min (27-Gal/Min) Unit
346
Connect Power to 220-L/Min
348
(58-Gal/Min) Unit
348
Front View
349
Disconnect Switch
349
Checkout
351
Installing CIP
351
Verifying Diagnostics
351
Checking Warning Systems
351
Checking Electromagnetic Compatibility
351
Master Oscillator Switch Locations
355
Dual-CP System Diagnostic Tests
359
Tests
360
Dual-CP System Quick-Look
361
Check CP Low-Temperature Sensor and SPM Cabling
362
Check 102-L/Min (27-Gal/Min) Unit Warning Cable to SPM
362
Check 220-L/Min (58-Gal/Min) Unit Warning Cable to SPM
362
SPM Indicators
363
Check CM and IOU Low-Temperature Sensor and SPM Cabling
366
102-L/Min (27-Gal/Min) Unit to SPM Cable Check
369
Running Network Operating System
372
Installing and Testing Optional
375
Modem Circuit Board
376
RTA Equipment
379
Advertisement
Advertisement
Related Products
Control Data CDC CYBER 845S
Control Data CDC CYBER 855S
Control Data CDC CYBER 840A
Control Data CDC CYBER 850A
Control Data 169
Control Data 1728-A
Control Data 1728-B
Control Data 3000 Series
Control Data 3121-A
Control Data 3121-B
Control Data Categories
Desktop
Computer Hardware
Controller
Storage
Card Reader
More Control Data Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL