Sign In
Upload
Manuals
Brands
Condair Manuals
Portable Generator
Omega Pro II
Condair Omega Pro II Manuals
Manuals and User Guides for Condair Omega Pro II. We have
2
Condair Omega Pro II manuals available for free PDF download: Operation Manual, Installation Manual
Condair Omega Pro II Operation Manual (84 pages)
Steam generator
Brand:
Condair
| Category:
Portable Generator
| Size: 4 MB
Table of Contents
Table of Contents
3
1 Introduction
5
To the very Beginning
5
Notes on the Operation Manual
5
2 For Your Safety
7
3 Product Overview
9
Construction Condair Omega Pro Steam Generator
9
Functional Description
10
System Overview SPA Cabin Humidification
11
System Overview Direct Room Humidification
12
4 Operation
13
First-Time Commissioning
13
Display and Operating Elements
13
Commissioning after an Interruption of Operation
14
Notes on Operation
15
Inspections During Operation
15
Remote Operating and Fault Indication
15
Draining the Steam Cylinder(S)
16
Taking the Unit out of Operation
17
5 Operating the Condair Omega Pro Control Software
18
Home Screen
18
Device and Error Status Indication Field
19
Control Indication Field
21
Maintenance Indication Field
22
Information Functions in the "Help" Menu
23
Accessing the "Help" Menu
23
Query Operating States in the "About" Submenu
23
Quick Access to Setting Parameters in the "Quick Access" Submenu
24
Configuration
25
Settings and Features in the "General" Submenu
25
Accessing the "General" Submenu
25
Determine Language and System of Units in the "Region" Submenu
25
Date and Time Settings in the "Date & Time" Submenu
26
Read in Parameter Settings in the "Backup" Submenu
26
Activate/Deactivate Password Protection in the "Password Settings" Submenu
27
Set the Brightness of the Touchscreen and the LED in the "Brightness" Submenu
27
Settings and Features in the "Maintenance" Submenu
28
Accessing the "Maintenance" Submenu
28
Reset Functions in the "Reset" Submenu
28
Settings in the "Water Management" Submenu
29
Software Update in the "Update" Submenu
31
View and Export Malfunctions and Maintenance Histories in the "Histories" Submenu
31
Load and Export the Error Log File in the "Error Analyzer" Submenu
32
Start Operating Data Recording in the "USB Data Logger" Submenu
32
View Operating States in the Submenu "Diagnostics > Input Diagnostic Cyl. A/B
33
Checking the Relays of the Remote Operating and Fault Indication Board in the "Diagnostics > RFI Diagnostics" Submenu
34
Settings and Features in the "Features" Submenu
34
Accessing the "Features" Submenu
34
Set the Power Limitation in the "Operation" Submenu
35
Setup Operation Timers in the "Timers" Submenu
35
Activate/Deactivate the Softstart Function in the "Softstart" Submenu
37
Activate/Deactivate the Demineralisation Function in the "Desalt" Submenu
37
Settings in the "Standby" Submenu
38
Settings in the "Drain Options" Submenu
39
Settings in the "Ext. Pipe Flush" Submenu
39
Settings and Features in the "Controls" Submenu
40
Accessing the "Controls" Submenu
40
Control Settings in the "Signal Settings" Submenu
40
Control Settings in the "Control CH1" Submenu
41
Settings in the "Device Interconnection" Submenu
43
Communication Settings in the "Network" Submenu
44
Accessing the "Network" Submenu
44
Settings in the "IP Settings" Submenu
45
Settings in the "Iot Settings" Submenu
46
Settings in the "Modbus Settings" Submenu
46
Settings in the "Bacnet Settings" Submenu
46
Settings in the "Remote Fault Indication" Submenu
47
Maintenance
48
Important Notes on Maintenance
48
Maintenance Intervals
49
Maintenance List
50
Preparing the Condair Omega Pro for the Removal of Components
51
Removing and Installing Components for Maintenance
51
Removal and Installation of the Scale Collector Tank
52
Removal and Installation of the Steam Cylinder
54
Removal and Installation of the Drain Cup
57
Removal and Installation of the Filling Cup, the Level Unit and the Water Hoses
58
Removal and Installation of the Drain Pump
59
Removal and Installation of the Inlet Valve
60
Removal and Installation of the Steam Cylinder Receptacle
61
Notes on Cleaning the Unit Components
62
Notes on Cleaning Agents
64
Resetting the Maintenance Counter
65
Performing a Software Update
66
Fault Elimination
67
Important Notes on Fault Elimination
67
Fault Indication
68
Malfunction List
70
Fault Behavior of Units in a Device Interconnected System
75
Saving Fault and Service Histories to a USB Memory Stick
76
Resetting Malfunction Indication
77
Replacing the Fuses and Backup Battery in the Control Unit
78
Taking out of Service/Disposal
79
Taking out of Service
79
Disposal/Recycling
79
Product Specification
80
Performance Data
80
Operating Data
81
Connections/Dimensions/Weights
81
Certificates
81
Advertisement
Condair Omega Pro II Installation Manual (72 pages)
Brand:
Condair
| Category:
Iron
| Size: 8 MB
Table of Contents
Proprietary Notice
2
Liability Notice
2
Copyright Notice
2
Table of Contents
3
Introduction
5
To the very Beginning
5
Notes on the Installation Manual
5
Language Versions
6
For Your Safety
7
Product Overview
9
Models Overview
9
Single Units Small ("S") , Omega Pro 5
9
Single Units Large ("L"), Omega Pro 50
10
Double Units (2 X "M"), Omega Pro 40
11
Device Interconnected Systems (3 X "M"), Omega Pro 100
12
Device Interconnected Systems (4 X "M"), Omega Pro 140
13
Product Designation
14
Model Designation
15
Options
16
Accessories
18
Receiving and Storage
19
Inspection
19
Storage and Transportation
20
Mounting and Installation Work
21
Safety Notes on Mounting and Installation Work
21
Installation Overviews
22
Mounting the Unit
24
Notes on Locating the Unit
24
Mounting the Steam Generator
26
5.3.2.1 Standard Mounting
26
Rail Mounting (Option)
29
Inspecting the Installed Unit
31
Steam Installation
32
Overviews Steam Installation
32
Positioning/Mounting the Steam Distributor
34
Positioning and Mounting of the Blower Packs (Accessory BP)
35
Installing the Steam and Condensate Lines
36
Installation Examples
37
Common Steam and Condensate Line Errors
41
Inspecting the Steam Installation
42
Water Installation
43
Overview Water Installation
43
Notes on Water Installation
45
Inspecting the Water Installation
47
Notes on Humidity Control for Direct Room Humidification
48
Principle Diagram Room Humidity Control
48
Electrical Installation
49
Notes on Electrical Installation
49
Wiring Diagram Condair Omega Pro 5
50
Wiring Diagram Condair Omega Pro 50
51
Wiring Diagram Condair Omega Pro 40
52
Wiring Diagram Condair Omega Pro 100
53
Installation Work External Connections
55
Connecting Multiple Units (Device Interconnected System)
63
Performance Data / Fuses "F3" Heating Voltage Supply
65
Inspecting the Electrical Installation
66
Appendix
67
Unit Dimensions
67
Unit Dimensions Unit "S" (Omega Pro 5
67
Unit Dimensions Unit "M" (Omega Pro 16
68
Unit Dimensions Unit "L" (Omega Pro 50
69
Advertisement
Related Products
Condair Omega Pro
Condair Omega Series
Condair Omega 2
Condair Omega 4
Condair Omega 6
Condair Omega 8
Condair Omega 12
Condair Omega 16
Condair Omega 20
Condair OptiSorp Series
Condair Categories
Humidifier
Dehumidifier
Water System
Iron
Dryer
More Condair Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL