Sign In
Upload
Manuals
Brands
CIAT Manuals
Industrial Equipment
DYNACIAT LGN Series
CIAT DYNACIAT LGN Series Manuals
Manuals and User Guides for CIAT DYNACIAT LGN Series. We have
2
CIAT DYNACIAT LGN Series manuals available for free PDF download: Service Manual, Instruction Manual
CIAT DYNACIAT LGN Series Service Manual (115 pages)
cooling / heating control
Brand:
CIAT
| Category:
Control Systems
| Size: 4 MB
Table of Contents
About this Document
2
Revisions History
3
Table of Contents
4
Abbreviations
8
Introduction
9
Purpose
9
Product Overview
9
Getting Started - Control Functions
10
Product Components
12
UNIT SIZE Vs. COMPRESSOR
12
Communication
13
RS-485 Port
13
Ethernet Port
13
Control Software
14
Software Overview
14
Software Download
14
How to Download Software Package Using HVAC S-Service
14
Connect Touch User Interface
16
Getting Started with Connect Touch User Interface
16
Connect Touch - Screen Overview
16
Access Levels
16
Web Interface
16
Password Management
17
System of Measurement
17
Language Display
17
Language Customization
18
Touch Screen Settings (Optional)
20
Setup Menu
20
Network Settings
20
Web Connection Settings
22
System Settings
23
Display Settings (Contrast, Screen Timeout, Calibration)
24
Keyboard Settings
24
Password Settings
24
Language Settings
24
Unit Configuration
25
Factory Configuration
25
Service Configuration
25
User Configuration
25
Detailed Menu Description
26
Main Menu
26
General Parameters Menu - GENUNIT
27
Temperature Menu - TEMP
28
Pressure Menu - PRESSURE
28
Setpoint Menu - SETPOINT
29
Inputs Menu - INPUTS
30
Outputs Menu - OUTPUTS
30
Pump Status Menu - PUMPSTAT
31
Runtime Menu - RUNTIME
32
DC Free Cooling Status Menu - DCFC_STA
32
Air Condensing Status Menu - AIR_COND
33
Miscellaneous Status Menu - MSC_STAT
33
Modes Menu - MODES
34
Alarms Menu
35
Configuration Menu - Config
36
Factory Parameters
37
Service Parameters
39
User Configuration
46
Network Parameters Menu
50
Modbus RTU Config. - MODBUSRS
50
Modbus TCP/IP Config. - MODBUSIP
51
Network Comfort Ctrl - NETCTRL
51
Bacnet Standard Conf. - BACCONF (Bacnet Table)
51
Email Configuration - EMAILCFG
52
Maintenance Menu - Maintain
53
Capacity EXV Ctrl - LOADFACT
54
Drive Control - DRV_CTRL
54
Master/Slave Maint - M_MSTSLV
55
Last Poweron Reset - LAST_POR
55
Protection Limit - PR_LIMIT
56
Service Maintenance - SERMAINT
56
Head Control - HEADCTRL
57
Quick Test Table
58
Quick Test Menu Table - QCK_TEST
58
Control Operations
59
Operating Modes
59
Unit Start / Stop (on / Off)
60
Conditions for Unit Start / Stop
60
Delay at Unit Start-Up
61
Stopping Process
61
Emergency Unit Stop
61
Heating / Cooling Mode
61
Runtimes Management
62
Hydronic Module Overview
62
Flow Switch
62
Cooler Pumps Control
63
Starting / Stopping Pumps
63
Pump Selection
63
Pumps in the Master/Slave Assembly
63
Periodical Pump Start-Up
64
Automatic Pump Control
64
Cooler Flow Switch Check When Unit Is off
64
Condenser Pumps Control
65
Starting / Stopping Pumps
65
Pump Selection
65
Periodical Pump Start-Up
65
Automatic Pump Control
66
Variable Water Flow Management
67
Methods of Water Flow Control
67
Water Loop Status
67
Water Loop Control
67
Electric Heating Control
68
Control Point
69
Setpoints
69
Reset Calculation
72
Electronic Expansion Valve (Exv)
73
EXV Control
73
EXV Overrides
73
Lead/Lag Circuit
74
Capacity Control
74
Capacity Control Management
74
Circuit Capacity Loading Sequence
74
Ramp Loading
75
Disabling Compressors
75
Capacity Overrides
76
Capacity Limitation
77
Demand Limit Control
77
Lag Capacity Limit Control (Master/Slave Assembly)
77
Night Mode Limit Control
77
Condensing Water Flow Control
78
Condensing Pressure Control
78
Condensing Setpoint Control
78
Dry Cooler Condenser Control
79
Installation
79
Condenserless Control (LGN Series)
79
Free Cooling (Dry Cooler)
80
Installation
80
Starting / Stopping Free Cooling
80
Free Cooling Temperatures
80
Master/Slave Control
81
Master/Slave Chillers
81
Lead/Lag Chiller Selection
81
Master Chiller Status
82
Master/Slave Operation Overview
82
Master/Slave Network Configuration
83
Master/Slave Assembly Error
84
Master/Slave Assembly
85
Service & Maintenance
87
Introduction to "Service Maintenance" Options
87
Resetting Service Maintenance Alerts
87
Refrigerant Charge Control
87
Water Loop Control
88
Next Service Maintenance Control
88
F-Gas Maintenance Control
88
Quick Test Function
89
Quick Test Overview
89
Quick Test Modes
89
Steps for Performing a Quick Test
89
Compressor(S)
89
Water Pump(S)
90
Condenser Single Speed Fan(S)
90
Single Speed Fan(S)
90
Head Pressure Position for LGN Units / Varifan for LG Units
90
Boiler
90
Electric Heating Stages
90
Liquid Line Valve
90
Way Valve
90
Alarm Notifications
91
Email Parameters and Configuration
91
Email Notification Process
91
Diagnostic Function
92
Alarms
92
Current Alarms
92
Alarms Reset
92
Alarms History
92
Alarm Codes
93
General Alarms
93
Variable Speed Alarm Sub-Codes
100
Communication Problem Troubleshooting
101
Hardware Problems
101
Web Interface Troubleshooting
101
Ethernet/Ip Troubleshooting
102
The Unit Is Point-To-Point Connected to a PC
102
Unit Connected to the Local Network
103
Ethernet Connection
104
Java Configuration
105
Hvac S-Service Communication Problem
106
Check TCP Port
106
Switch to BOOTER Mode
109
Boards Description
110
Siob Circuita Board Mapping
110
Siob Circuitb Board Mapping
111
Aux1 #1 Board Mapping (Electric Heating Stages)
112
Aux1 #2 Board Mapping
112
Aux1 #4 Board
113
Aux1 #5 Board
113
Appendix
114
Advertisement
CIAT DYNACIAT LGN Series Instruction Manual (68 pages)
Brand:
CIAT
| Category:
Industrial Equipment
| Size: 16 MB
Table of Contents
Table of Contents
4
1 Introduction
6
Installation Safety Considerations
6
Equipment and Components under Pressure
7
Maintenance Safety Considerations
7
Repair Safety Considerations
8
Measures, Provisions, Procedures against Emergencies
9
2 Preliminary Checks
10
Check Equipment Received
10
Moving and Placing the Unit
10
3 Dimensions, Clearances
12
LG 080 - 150 - Standard Unit
12
LG 180 - 300 - Standard Unit
12
LG 360 - 450 - Standard Unit
13
LG 480 - 600 - Standard Unit
13
LGN 080 - 150 - Standard Unit
14
LGN 180 - 300 - Standard Unit
14
LGN 360 - 450 - Standard Unit
15
LGN 480 - 600 - Standard Unit
15
LG 080 - 150 - Unit with Hydraulic Module
16
LG 180 - 300 - Unit with Hydraulic Module
16
LG 360 - 450 - Unit with Hydraulic Module
17
LG 480 - 600 - Unit with Hydraulic Module
17
LGN 080 - 150 - Unit with Hydraulic Module
18
LGN 180 - 300 - Unit with Hydraulic Module
18
GN 360 - 450 - Unit with Hydraulic Module
19
LGN 480 - 600 - Unit with Hydraulic Module
19
4 Physical and Electrical Data
20
Physical Data
20
Electrical Data
24
Short-Circuit Stability Current (TN System(1)) - Standard Unit (with Main Disconnect Switch)
26
Electrical Data, Optional Hydraulic Module
27
Compressor Usage and Electrical Data Table
30
5 Application Data
32
Operating Limits
32
Operating Range
33
Minimum Chilled Water Flow
33
Maximum Chilled Water Flow
33
Variable Flow
33
Min Water Volume and Evaporator & Condenser Water Flow Rates
34
Maximum Water Loop Volume (Evaporator and Condenser Side)
35
Expansion Tank
35
Protection against Cavitation Evaporator Pumps Option
35
Plate Heat Exchanger Pressure Drop (Includes Internal Piping)
36
6 Electrical Connection
37
Electrical Connections, Control Box
37
Power Supply
37
Voltage Phase Imbalance (%)
37
Recommended Wire Sections
37
24 V User Power Reserve
38
7 Lgn Unit Connections
39
Recommendations for the Installation of Liquid Chillers with Remote Condenser
39
Pipe Routing and Connection
39
8 Sizing the Refrigerant Pipes with Refrigerant for Lgns
40
General Information and Sizing Limits for the Pipe System
40
Sizing the Pipes
40
Sizing the Discharge Pipe
42
Sizing the Liquid Pipe
42
9 Water Connections
43
Operating Precautions
43
Frost Protection
46
Flow Switch (Units Without Hydraulic Module)
46
10 Nominal Water Flow Control with Fixed-Speed Pump
47
General
47
Water Flow Control Procedure
47
11 Nominal Water Flow Control with Variable-Speed Pump
49
Pump Flow/Pressure Curve
49
Available External Static Pressure (Low-Pressure Pumps, Units with Hydraulic Module)
49
Available External Static Pressure (High-Pressure Pumps, Units with Hydraulic Module)
50
12 Start-Up
51
Preliminary Checks
51
Actual Start-Up
51
13 Major System Components and Operation Data
52
Compressors
52
Lubricant
52
Evaporators and Water Condensers
52
Electronic Expansion Valve (EXV)
52
Refrigerant
52
High-Pressure Switch and High-Pressure Sensor
53
High and Low-Pressure Side Relief Valves
53
Moisture Indicator
53
Filter Drier in the Refrigerant Circuit
53
Evaporator and Condenser Pump Suction Filter
53
External Temperature Sensor
53
14 Options Et Accessories
54
Options Table
54
Description
55
15 Maintenance
60
Soldering and Welding
60
General System Maintenance
60
Refrigerant Undercharge
60
Refrigerant Guidelines
60
Leak Detection
60
Evacuation
61
Recharging Liquid Refrigerant
61
Characteristics of R-410A
61
Electrical Maintenance
61
Tightening Torques for the Main Electrical Connections
62
Tightening Torques for the Main Bolts and Screws
62
Compressors
62
Evaporator and Condenser Maintenance
62
Corrosion Check
62
16 Dynaciat Maintenance Program
63
Maintenance Schedule
63
Description of the Maintenance Operations
63
17 Final Shutdown
64
Shutting down
64
Recommendations for Disassembly
64
Fluids to be Recovered for Treatment
64
Materials to be Recovered for Recycling
64
Waste Electrical and Electronic Equipment (WEEE)
64
18 Start-Up Ckecklist for Units (Use for Job File)
65
Advertisement
Related Products
CIAT DYNACIAT LG Series
CIAT DynaCIAT LG
CIAT DynaCIAT LGN
CIAT DYNACIATpower LG Series
CIAT DYNACIATpower LGP Series
CIAT DYNACIAT LGP
CIAT MAGISTER DXA 70
CIAT Junior BCP DUAL 20
CIAT Ciatronic DD 175
CIAT DFU
CIAT Categories
Air Conditioner
Chiller
Heat Pump
Air Handlers
Control Unit
More CIAT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL