Sign In
Upload
Manuals
Brands
Christ Manuals
Dryer
ALPHA 1-2 LDplus
Christ ALPHA 1-2 LDplus Manuals
Manuals and User Guides for Christ ALPHA 1-2 LDplus. We have
4
Christ ALPHA 1-2 LDplus manuals available for free PDF download: Operating Manual
Christ ALPHA 1-2 LDplus Operating Manual (94 pages)
Freeze-dryer
Brand:
Christ
| Category:
Freezer
| Size: 3 MB
Table of Contents
Table of Contents
5
1 General Information
9
Importance of the Operating Manual
9
Intended Use
9
Warranty and Liability
11
Copyright
12
Explanation of Symbols
12
Standards and Regulations
12
Scope of Supply
12
2 Layout and Mode of Operation
13
Layout of the Freeze-Dryer
13
Functional and Operating Elements
13
Name Plate
15
Mode of Operation
16
General Information on Freeze-Drying
16
Freeze-Drying Process
18
Preparation
18
Freezing
19
Main Drying
19
Final Drying
19
End of Drying and Aeration
20
Defrosting
20
3 Safety
21
Marking of the Unit
21
Explanation of the Symbols and Notes
22
Responsibility of the Operator
23
Operating Personnel
24
Informal Safety Notes
24
Safety Notes Concerning the Transport, Set-Up and Connection and Initial Start-Up of the Freeze-Dryer
24
General Hazards
24
Hazards Caused by Improper Transport
25
Hazards Caused by Improper Set-Up
25
Hazards Caused by Improper Connection
26
Safety Notes Concerning the Operation
26
Hazards Caused by Electricity
26
Hazards Caused by the Refrigeration System (Natural, Flammable Refrigerants)
27
Hazards Caused by the Refrigeration System (Non-Flammable Refrigerants)
27
Hazards Caused by Harmful Products
28
Hazards Caused by Solvents in the Products
28
Hazards Caused by Acids in the Products
28
Hazards Caused by Contaminated Condensate (Defrosting Water)
29
Hazards Caused by Hot Surfaces
29
Hazards Caused by Cold Surfaces
29
Safety Devices
29
System Check
29
Earth Conductor Check
29
Procedures in the Event of Hazards and Accidents
30
Maintenance and Cleaning of the Freeze-Dryer
30
Measures to be Taken to Ensure Safe Operation of the Freeze-Dryer
31
Remaining Hazards
32
4 Storage and Transport
33
Dimensions and Weight
33
Storage Conditions
33
Notes on Transport
34
Packaging
35
Transport Safety Device
35
5 Set-Up and Connection
36
Location of Use
36
Power Supply
37
Type of Connection
37
Customer-Provided Fuses
37
Aeration and Media Drain Valve
38
Vacuum Sensor
38
Vacuum Pump
40
Pressure Control Valve
41
Rubber Valves
42
6 Operation
43
Initial Start-Up
43
Installation of Accessories
43
Preparation
43
Switching the Freeze-Dryer on
43
Ldplus Control System
44
User Interface
44
Mode
47
Main Menu
49
Changing Set Values
49
Special Functions
51
Process and Equipment Information
52
Options
53
Tutorial
55
Switching the Freeze-Dryer off
56
7 Malfunctions and Error Correction
57
General Malfunctions
57
Power Failure
57
Insufficient Vacuum
57
Small Flange Connections
57
Aeration and Media Drain Valve
58
Pressure Control Valve
58
Rubber Valves
59
Vacuum Sensor
59
Insufficient Ice Condenser Temperature
59
Process and Equipment Messages
60
Service Contact
61
8 Maintenance and Service
62
Maintenance
62
General
62
Ice Condenser Chamber
63
Aeration Valve, Media Drain Valve
64
Heat Exchanger (Only for Air-Cooled Freeze-Dryers)
65
Electrical System
65
Vacuum Pump
65
Exhaust Filter (Oil Mist Separator)
66
Refrigeration System
67
Vacuum Sensor
67
8.1.10 Accessories
68
Disinfection of the Drying Chamber and Accessories
69
Service
70
Return of Defective Parts
70
9 Disposal
72
Disposal of the Freeze-Dryer
72
Disposal of the Packaging
72
10 Technical Data
73
Ambient Conditions
74
Technical Documentation
74
11 Appendix
75
Brief Operating Instructions
75
EC Declaration of Conformity in Accordance with the EC Machinery Directive
81
Declaration of Conformity - China Rohs 2
83
EC Declaration of Conformity in Accordance with the Pressure Equipment Directive
85
Table of the Sublimation Pressure Curve
87
12 Glossary
89
13 Index
91
Advertisement
Christ ALPHA 1-2 LDplus Operating Manual (102 pages)
Freeze-dryer
Brand:
Christ
| Category:
Laboratory Equipment
| Size: 1 MB
Table of Contents
Table of Contents
5
1 General Information
9
Importance of the Operating Manual
9
Intended Use
9
Warranty and Liability
10
Copyright
10
Explanation of Symbols
10
Standards and Regulations
10
Scope of Supply
10
2 Layout and Mode of Operation
11
Layout of the Freeze-Dryer
11
Functional and Operating Elements
11
Name Plate
13
Mode of Operation
14
General Information on Freeze-Drying
14
Freeze-Drying Process
17
Preparation
17
Freezing
17
Main Drying
18
Final Drying
19
End of Drying and Aeration
19
Defrosting
20
3 Safety
21
Marking of the Unit
21
Explanation of the Symbols and Notes
22
Responsibility of the Operator
23
Operating Personnel
23
Informal Safety Instructions
24
Safety Instructions
24
Electrical Safety
25
Mechanical Safety
25
Fire Prevention
26
Thermal Safety
26
Chemical and Biological Safety
26
Safety Devices
27
System Check
27
Earth Conductor Check
27
Procedures in the Event of Hazards and Accidents
27
Remaining Hazards
28
4 Storage and Transport
29
Dimensions and Weight
29
Storage Conditions
29
Notes on Transport
30
Packaging
31
Transport Safety Device
31
5 Set-Up and Connection
32
Installation Site
32
Power Supply
33
Connection
33
Customer-Provided Fuses
33
Aeration and Media Drain Valve
33
Vacuum Sensor
34
Vacuum Pump
36
Pressure Control Valve
37
Rubber Valves
38
6 Operation
39
Initial Start-Up
39
Installation of Accessories
39
Preparation
39
Switching the Freeze-Dryer on
39
Ldplus Control System
40
User Interface
40
Mode
43
Main Menu
45
Changing Set Values
45
Special Functions
47
Process and Equipment Information
48
Options
49
Tutorial
51
Switching the Freeze-Dryer off
52
7 Malfunctions and Error Correction
53
General Malfunctions
53
Power Failure
53
Insufficient Vacuum
53
Small Flange Connections
53
Aeration and Media Drain Valve
54
Pressure Control Valve
55
Rubber Valves
55
Vacuum Sensor
55
Insufficient Ice Condenser Temperature
55
Process and Equipment Messages
56
Service Contact
58
8 Maintenance and Service
59
Maintenance
59
General
59
Ice Condenser Chamber
60
Aeration Valve, Media Drain Valve
60
Heat Exchanger (Only for Air-Cooled Freeze-Dryers)
61
Vacuum Pump
61
Exhaust Filter (Oil Mist Separator)
62
Vacuum Sensor
62
Accessories
62
Disinfection of the Drying Chamber and Accessories
63
Service
64
Return of Defective Parts
64
9 Disposal
66
Disposal of the Freeze-Dryer
66
Disposal of the Packaging
66
10 Technical Data
67
Ambient Conditions
69
Technical Documentation
69
11 Appendix
70
Brief Operating Instructions
70
EC Declaration of Conformity in Accordance with the EC Machinery Directive
75
Declaration of Conformity - China Rohs 2
77
Resistance to Stress Cracking and Chemical Influences "Plexiglas
79
12 Glossary
97
13 Index
99
Christ ALPHA 1-2 LDplus Operating Manual (107 pages)
Freeze Dryer
Brand:
Christ
| Category:
Dryer
| Size: 3 MB
Table of Contents
Table of Contents
7
1 General Information
9
Introduction
9
Applications
10
Technical Specifications of Freeze Dryer ALPHA 1- 2 LD
11
Plus
11
Standards and Regulations
14
Safety Instructions
14
CAUTION! Disconnect Mains Plug
14
CAUTION! Solvents
14
ADVICE! Cleaning and Maintenance of the Unit
14
WARNING! Freezing of Limbs to Surfaces
14
ADVICE! Transport Instructions
15
Prohibited Freeze Drying Processes
16
2 General Information on Freeze Drying
17
Preparation
20
Freezing
20
Main Drying
21
Final Drying
25
End of Drying and Aeration
25
Defrosting
26
3 Description of the Freeze Drying Processes
27
Separate Freezing and Drying Outside the Ice Condenser Chamber (Process B) on Shelves
27
Separate Freezing and Drying Outside the Ice Condenser Chamber (Process B) with Sealing Device
28
Separate Freezing and Drying of Liquids in Flasks (Process B)
29
Separate Freezing and Drying of Liquids in Ampoules (Process B)
30
4 Installation and Commissioning of the Unit
33
Site of Installation
33
Mains Electricity
34
Fuses on Site
34
Checking the Earth Connection
34
Aeration
34
Condensate and Defrosting Water
34
Vacuum Pump Exhaust
35
Initial Start-Up
35
Functional Components and Control Elements
36
Connection of Vacuum Sensor Vacuum Pump, and Pressure Control Valve
37
Switching-On
43
5 Ldplus Control System
45
Introduction
45
Ldplus Control Panel
45
Brief Guide - Handling
46
Visual Components of the Ldplus Control System
47
Main Window
47
Status Bar
47
Softkey Function
48
Values Window
49
Mode
50
Starting a Drying Process
50
Changing the Phase
50
Timer
50
Main Menu
51
Change Set Values
51
Special Functions
52
Process and Equipment Information System
53
Options
53
Tutorial
54
Process and Equipment Information System
55
Information Status
55
Ldplus Special Functions
56
Defrost Ice Condenser (Option)
56
Electrical Lifting Device (Option)
56
6 Error Correction
57
Power Failure
57
Insufficient Vacuum
57
Unit Does Not Function
59
Insufficient Ice Condenser Temperature
59
Process and Equipment Information System
60
Error Messages
60
7 Maintenance
63
Ice Condenser Chamber
63
Heat Exchanger
63
Adjustment and Maintenance of the Vacuum Sensor VSP62
63
Maintenance of the Vacuum Sensor
63
Replacement and Adjustment
64
Rubber Valves
65
Vacuum Pump
65
Exhaust Filter
65
Cleaning
66
Cleaning of the Freeze Dryer
66
Cleaning of Accessories
66
Maintenance of the Aeration Valve and the Drain Valve
66
Disinfection of Drying Chamber, Lid and Accessories
67
Checks by Operator
67
8 Options
69
Process Control System LPC-32, Software
69
Process Control System LPC-32, Software with PC Hardware
69
Lyolog LL-1 (Documentation Software)
69
Ldplus Simulation Tool (Training Software)
69
9 Enclosures
71
10 Special Functions
87
Alpha 1-2
92
A Anlage - Allgemein
93
Unit General
93
B Belüftungssystem / Ablaufsystem
94
Aeration System / Drain System
94
K1 Kältesystem
95
Cooling System 1
95
M Meßsysteme
96
Measurement System
96
Vakuumsystem
97
Vacuum System
97
Advertisement
Christ ALPHA 1-2 LDplus Operating Manual (96 pages)
Freeze-dryer
Brand:
Christ
| Category:
Dryer
| Size: 2 MB
Table of Contents
Table of Contents
5
1 General Information
9
Importance of the Operating Manual
9
Intended Use
9
Warranty and Liability
10
Copyright
10
Explanation of Symbols
10
Standards and Regulations
10
Scope of Supply
11
2 Layout and Mode of Operation
12
Layout of the Freeze-Dryer
12
Functional and Operating Elements
12
Name Plate
14
Mode of Operation
15
General Information on Freeze-Drying
15
Freeze-Drying Process
18
Preparation
18
Freezing
18
Main Drying
19
Final Drying
20
End of Drying and Aeration
20
Defrosting
20
3 Safety
21
Marking of the Unit
21
Explanation of the Symbols and Notes
22
Responsibility of the Operator
23
Operating Personnel
23
Informal Safety Instructions
23
Safety Instructions
24
Electrical Safety
24
Mechanical Safety
25
Fire Prevention
25
Thermal Safety
26
Chemical and Biological Safety
26
Safety Devices
27
System Check
27
Earth Conductor Check
27
Procedures in the Event of Hazards and Accidents
27
Remaining Hazards
28
4 Storage and Transport
29
Dimensions and Weight
29
Storage Conditions
29
Notes on Transport
30
Packaging
31
Transport Safety Device
31
5 Set-Up and Connection
32
Installation Site
32
Power Supply
32
Connection
32
Customer-Provided Fuses
32
Aeration and Media Drain Valve
33
Vacuum Sensor
33
Vacuum Pump
35
Pressure Control Valve
35
6 Operation
36
Initial Start-Up
36
Installation of Accessories
36
Preparation
36
Switching the Freeze-Dryer on
36
Ldplus Control System
37
User Interface
37
Mode
40
Main Menu
42
Changing Set Values
42
Special Functions
44
Process and Equipment Information
45
Options
46
Tutorial
48
Switching the Freeze-Dryer off
49
7 Malfunctions and Error Correction
50
General Malfunctions
50
Power Failure
50
Insufficient Vacuum
50
Small Flange Connections
50
Aeration and Media Drain Valve
51
Pressure Control Valve
52
Rubber Valves
52
Vacuum Sensor
52
Insufficient Ice Condenser Temperature
53
Process and Equipment Messages
54
Service Contact
55
8 Maintenance and Service
56
Maintenance
56
Freeze-Dryer
56
Ice Condenser Chamber
57
Drying Chamber
57
Aeration Valve, Media Drain Valve
57
Heat Exchanger (Only for Air-Cooled Freeze-Dryers)
58
Vacuum Pump
58
Exhaust Filter (Oil Mist Separator)
59
Vacuum Sensor
59
Accessories
60
Disinfection of the Drying Chamber and Accessories
60
Service
61
Return of Defective Parts
62
9 Disposal
63
Disposal of the Freeze-Dryer
63
Disposal of the Packaging
63
10 Technical Data
64
Ambient Conditions
65
Technical Documentation
65
11 Appendix
66
Brief Operating Instructions
66
EC Declaration of Conformity
71
Resistance to Stress Cracking and Chemical Influences "Plexiglas
73
12 Glossary
91
13 Index
93
Advertisement
Related Products
Christ ALPHA 1-4 LDplus
Christ ALPHA 2-4 LDplus
Christ Alpha 1-4 LSCplus
Christ Alpha 2-4 LSCplus
Christ Alpha 3-4 LSCbasic
Christ Alpha 1-4 LSCbasic
Christ Alpha 2-4 LSCbasic
Christ Alpha 1 LSCbasic
Christ Alpha 2 LSCbasic
Christ 102124
Christ Categories
Laboratory Equipment
Dryer
Touch Panel
Industrial PC
Freezer
More Christ Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL