Manuals and User Guides for Ceyear 1465H-V Signal Generator. We have
2
Ceyear 1465H-V Signal Generator manuals available for free PDF download: User Manual, Quick Start Manual
Ceyear 1465H-V User Manual (284 pages)
Signal Generator
Brand:
Ceyear
| Category:
Laboratory Equipment
| Size: 13.89 MB
Table of Contents
Table of Contents
5
About this Manual
11
Related Documents
12
Overview
15
General
15
Product Features
15
Typical Applications
21
Safety Guide
22
Safety Signs
23
Electrical Safety
24
Operating Status and Positions
24
Operation Status and Position
24
Battery or Power Module
25
Maintenance
25
Operation Precautions
25
Disposal/Environmental Protection
26
Transportation
26
Transportion
26
Start Guide
27
Preparation before Use
27
Preparations before Operation
27
Configuration of Operating System
37
Routine Maintenance
42
Description of Front and Rear Panels
43
Description of Front Panel
43
Description of Rear Panel
45
Basic Configuration Method
47
Description of Basic Settings
47
Example of Operation
52
Description of Main Configuration Scenarios
61
Frequency
62
Amplitude
63
Sweep
64
Simulation Modulation
66
Base
67
Data Management
68
System
68
Saving/Loading of Working State
69
File Management
70
Printing/Saving of Screenshot
73
Operation Guides
75
Basic Operation Guides
75
Digital Modulation
75
Simulation Modulation and Pulse Modulation
76
Sweep
79
Advanced Operation Guides/Configuring Multi-Tone
82
Advanced Operation Guides
82
Configuring Multi-Tone
82
ARB Configuration
84
Selecting ALC Bandwidth
84
Selecting ALC Bandwidth
90
External Level Control
91
Working with a Frequency Mixer/Effects of Reverse Power
92
Creating and Applying a User Flatness Correction Array
93
Selecting Pulse Modulation Input
94
Pulse Modulation Input Selection
94
Baseband Trigger Function Configuration
97
Baseband Triggering Function Configuration
97
Arbitrary Waveform Triggering Function Configuration
100
Menu Structure and Parameter Settings/Frequency
105
Menu
105
Menu Structure and Parameter Settings
105
Frequency
105
Amplitude
107
Sweep
109
Modulation
111
Base
117
I/Q
119
Arb
120
Tone
122
AWGN (Option)
123
System
124
File
128
Save/Recall
128
Calibrate
129
Menu Description/Frequency
130
Menu Description
130
Frequency
130
Ampl
135
Amplitude
135
Sweep
141
Modulation
147
Base
154
I/Q
159
Arb
166
Tone
173
AWGN (Option)
176
System
179
File
181
Save/Recall
182
Calibrate
182
6 Remote Control
185
Remote Control Basis
185
Remote Interface
185
Remote Control Basis Remote Interface
185
Message
188
Scpi
188
Command Sequence and Synchronization
196
Status Reporting System
197
Programming Considerations
199
6.1 Remote Control Basis
188
Remote Interface and Its Configuration
199
Lan
199
Gpib
200
Basic Programming Method of the VISA Interface
201
VISA Library
201
Basic Programming Method of VISA Interface
201
Initialization and Default Status Setting
202
Sending of Set Command
203
Reading of Instrument Configuration
203
Synchronization of Command
204
I/O Library
205
Overview of I/O Library
205
Installation and Configuration of I/O Library
206
Fault Diagnosis & Repair
207
Operating Principle
207
Instrument Operating Principle & Functional Block Diagram of Hardware
207
7.2 Fault Diagnosis and Troubleshooting Note
209
Fault Diagnosis and Troubleshooting
209
System Issue
209
Unlocked Hardware
209
Ready Lamp Fails
209
Fan Fails after Power on
209
Unfixed Amplitude
211
Cold Timebase
211
RF Output Power Issue
212
RF Output Port Unmodulated
212
Sweeping Issue
213
Data Storage Issue
213
Unresponsive Front Panel Keys
213
Remote Control Issue
213
Error Information
214
Error Information File
214
Error Information Description
214
Repair Methods
215
Contact Us
215
Packaging and Transport
216
Specifications and Test Methods
217
Statement
217
Product Features
217
Specifications
218
Option Information
228
Supplementary Information
230
General Information
230
Performance Characteristics Test
232
Recommended Test Method
232
Performance Characteristics Test Record Table
245
Recommended Instruments for Performance Characteristics Test
256
Appendixes/Appendix a Explanations of Terms
257
Appendix A Explanations of Terms
257
Frequency Accuracy
257
Frequency Stability
257
Harmonic Distortion and Spectrum Purity
257
I/Q Modulation
258
Speech Coding
258
Channel Coding
259
Digital Modulation
259
Frequency Band Utilization of Digital Modulation Signals
260
Binary Frequency Shift Keying 2FSK
260
Binary Phase Shift Keying BPSK
260
Quadrature Phase Shift Keying QPSK
261
Phase Shift Keying 8PSK
261
Quadrature Amplitude Modulation QAM
262
Differential Modulation Method Π/4Dqpsk
262
QPSK Modulation Method
263
Constant Envelope Digital Modulation MSK (Minimum Shift Keying)
263
3Π/8 Rotation 8PSK Modulation (EDGE)
264
Nyquist Filter
264
3Π/8 Rotation 8PSK Modulation
264
Nyquist Filter Coefficient Α
265
Appendixes
257
Appendix B Lookup Table of Scpis
266
Appendix C Lookup Table of Error Information
283
Appendix D Lookup Table of PC Keyboard in Function Configuration Windows
284
Advertisement
Ceyear 1465H-V Quick Start Manual (51 pages)
Signal Generator
Brand:
Ceyear
| Category:
Recording Equipment
| Size: 3.37 MB
Table of Contents
Quick Start Guide
1
Signal Generator
1
Table of Contents
5
1 Manual Navigation
7
About the Manual
7
Related Documents
7
2 Getting Prepared
9
Preparations before Operation
9
Getting Prepared Preparations before Operation
9
Unpacking
10
Instrument Placement and Installation
11
Power on / off
11
Correct Use of Connectors
13
User Check
15
Online Help
16
Operating System Configuration
18
Appearance of Instrument
22
3 Typical Applications
27
Setting CW RF Output Frequency at 500 Mhz and Power Level at 0 Dbm
27
Generating am Signals: lo Frequency of 3.5 Ghz, Modulation Rate of 1 Khz, and am Depth of
30
Generating Pulse Modulation Signals: lo Frequency of 3.5 Ghz, Pulse Width of 50Us, and Period of 1 Ms
32
Configuring Step Sweep: Start Frequency of 1 Ghz, Stop Frequency of 3 Ghz, and 5 Step Points
33
Configuring List Sweep: Start Frequency of 1 Ghz, Stop Frequency of 3 Ghz, and 5 List Points29
35
Configuring Ramp Sweep: Start Frequency of 1 Ghz, Stop Frequency of 3 Ghz
37
Configuring Baseband: Data Source PN Sequence, Modulation Type QPSK, and Code Element Rate of 4 Msps
38
Sequence Playback Function
40
Arbitrary Wave Playback Function
42
Selecting ALC Bandwidth
44
Setting Reset State
45
Storing / Calling a User State
46
Copying / Moving / Deleting Files
48
4 Getting Help
49
Basic Checks
49
Help Information
50
Repair
51
Advertisement
Related Products
Ceyear 1465H
Ceyear 1465A
Ceyear 1465C
Ceyear 1465B
Ceyear 1465F
Ceyear 1465D
Ceyear 1465B-V
Ceyear 1465A-V
Ceyear 1465C-V
Ceyear 1465D-V
Ceyear Categories
Measuring Instruments
Portable Generator
Test Equipment
Recording Equipment
Amplifier
More Ceyear Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL