Sign In
Upload
Manuals
Brands
Canberra Manuals
Amplifier
2016A
Canberra 2016A Manuals
Manuals and User Guides for Canberra 2016A. We have
1
Canberra 2016A manual available for free PDF download: User Manual
Canberra 2016A User Manual (58 pages)
Amplifier/TCA
Brand:
Canberra
| Category:
Amplifier
| Size: 0.32 MB
Table of Contents
Table of Contents
3
Introduction
6
Amplifier Function
6
Pulse Height Analyzer Function
6
Multiplexer Function
7
ICB Control
7
Controls and Connectors
8
Front Panel Controls
8
Rear Panel Connectors
9
Internal Controls
10
Amplifier Board
10
TCA Board
11
Amplifier Operation
12
Hardware Installation
12
Preventive Maintenance
12
Amplifier Setup
13
Preamp Fall Time Matching
14
Operation with ADC and MCA
15
ADC Setup
16
Spectroscopy Operation
16
Using the Genie-VMS Software
17
Calibration Procedure
17
Gain Normalization Procedure
20
TCA Window Setup
21
View Setup Parameters
22
Download Setup Values
22
Using the Genie-Pc/Genie-2000 Software
23
Calibration Procedure
23
Gain Normalization Procedure
27
TCA Window Setup
28
View Setup Parameters
29
Download Setup Values
29
Circuit Description
30
Amplifier
30
Input Amplifier
30
Differentiator and Gain Stages
30
Gain Stage Stabilizer
31
Active Filters
31
Unipolar Output
31
Baseline Restorer
31
Restorer Gate, Auto Threshold and Auto Rate
32
Fast Discriminator
32
Bipolar Amplifier and Crossover Timing
32
Inhibit Input
33
Triple Channel Analyzer
33
Computer Controlled Logic
33
SCA Front End
33
SCA Logic
34
Pileup Rejector
35
SCA Output Drivers
36
Specifications
37
Inputs
37
Outputs
37
Indicators
38
Pileup Rejector
38
Internal Jumpers
38
Manual Controls
39
Computer Controls
39
Performance
39
Power Requirements
40
Physical
40
Environmental
40
Ordering Information
41
Performance Adjustments
42
Pole/Zero Matching Using an Ultra Lege Detector and Fe
42
Pole/Zero Matching Using a Square Wave Generator
44
Baseline Restorer Mode
46
Amplifier Shaping Selection
46
Operation with Reset Preamps
47
P/Z Compensation with Reset Preamps
47
Using the Reset Preamp Inhibit Signal
48
Triangular Shaping
48
ICR Threshold Adjustment
49
Optimizing the Discriminator
49
ADC Peak Detect Adjustment
49
Calibration and Normalization
50
VMS Software Installation
52
Defining the Detectors
53
PC Software Installation
54
Defining the Detectors
55
Installation Considerations
56
Advertisement
Advertisement
Related Products
Canberra 2016
Canberra 2016B
Canberra 2012
Canberra 2015A
Canberra 2037A
Canberra Categories
Measuring Instruments
Amplifier
Signal Processors
Power Supply
Dispenser
More Canberra Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL