Bovie A950 Manuals
Manuals and User Guides for Bovie A950. We have
1
Bovie A950 manual available for free PDF download: User Manual
Bovie A950 User Manual (52 pages)
Brand:
Bovie
| Category:
Medical Equipment
| Size: 1 MB
Table of Contents
Equipment Covered in this Manual
4
For Information Call
4
Conventions Used in this Guide
4
Table of Contents
5
Introducing the Aaron 950™ Electrosurgical Generator
8
Key Features
9
Components and Accessories
9
Safety
9
Controls, Indicators, and Receptacles
12
Front Panel
13
Figure 2 - 1 Layout of Controls, Indicators, and Receptacles on the Front Panel
13
Symbols on the Front Panel
14
Cut, Blend, and Coag Controls
15
Figure 2 - 2 Controls for the Cut, Blend, and Coag Modes
15
Fulguration, Bipolar, and Preset Controls
16
Figure 2 - 3 Controls for the Fulguration and Bipolar Modes and Presets
16
Indicators and Receptacles
17
Figure 2 - 4 Indicators and Receptacles
17
Rear and Side Panels
18
Symbols on the Rear Panel
18
Symbols on the Side Panel
18
Figure 2 - 5 Layout of Controls and Indicators on the Rear and Side Panels
18
Getting Started
20
Initial Inspection
21
Installing the Unit
21
Figure 3 - 1 Mounting Kit
21
Using the Aaron 950
22
Inspecting the Generator and Accessories
23
Setup Safety
23
Setting up
24
Using and Understanding the Aaron 950™ Memory Features
25
Storing and Recalling Preset Settings
25
Preparing for Monopolar Surgery
25
Applying the Patient Return Electrode
25
Preparing for Bipolar Surgery
26
Activation Safety
27
Activating the Unit
28
Monopolar Activation
28
Bipolar Activation
28
Figure 4 - 1 Setup Procedures
29
Maintaining the Aaron 950
30
Cleaning
31
Periodic Inspection
31
Troubleshooting
32
Repair Policy and Procedures
34
Responsibility of the Manufacturer
35
Returning the Generator for Service
35
Step 1 - Obtain a Returned Goods Authorization Number
35
Step 2 - Clean the Generator
35
Step 3 - Ship the Generator
35
Technical Specifications
36
Performance Characteristics
37
Input Power
37
Duty Cycle
37
Dimensions and Weight
37
Operating Parameters
37
Transport and Storage
37
Audio Volume
38
Low Frequency (50-60 Hz) Leakage Current
38
High Frequency (RF) Leakage Current
38
Standards and IEC Classifications
39
Class I Equipment (IEC 60601-1
39
Type BF Equipment (IEC 60601-1) / Defibrillator Proof
39
Drip Proof (IEC 60601-2-2
39
Electromagnetic Interference
39
Electromagnetic Compatibility (IEC 60601-1-2 and IEC 60601-2-2
39
Voltage Transients (Emergency Generator Mains Transfer
39
EMC Compliance
39
Output Characteristics
43
Maximum Output for Bipolar and Monopolar Modes
43
Output Power Curves
44
Monopolar Cut Curves
44
Figure a - 1 Output Power Versus Impedance for Cut Mode
44
Figure a - 2 Peak Voltage Versus Power Setting for Cut Mode
44
Figure a - 3 Output Power Versus Impedance for Blend Mode
45
Figure a - 4 Peak Voltage Versus Power Setting for Blend Mode
45
Monopolar Coag Curves
46
Figure a - 5 Output Power Versus Impedance for Coagulation Mode
46
Figure a - 6 Peak Voltage Versus Power Setting for Coagulation Mode
46
Figure a - 7 Output Power Versus Impedance for Fulguration Mode
47
Figure a - 8 Peak Voltage Versus Power Setting for Fulguration Mode
47
Bipolar Curves
48
Figure a - 9 Output Power Versus Impedance for Bipolar Mode
48
Figure a - 10 Peak Voltage Versus Power Setting for Bipolar Mode
48
Warranty
50
Advertisement
Advertisement
Related Products
Bovie Aaron 1250
Bovie Aaron 950
Bovie Aaron 940
Bovie DERM A942 ESU
Bovie AARON 900
Bovie AARON 2250
Bovie DERM 101
Bovie DERM 102
Bovie DERM 941
Bovie DERM 942
Bovie Categories
Medical Equipment
Portable Generator
Fan
Inverter
Laboratory Equipment
More Bovie Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL