Sign In
Upload
Manuals
Brands
bonitron Manuals
Controller
M3460
bonitron M3460 Manuals
Manuals and User Guides for bonitron M3460. We have
2
bonitron M3460 manuals available for free PDF download: Customer Reference Manual, Reference Manual
bonitron M3460 Reference Manual (64 pages)
Ride-Thru Voltage Regulator
Brand:
bonitron
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
4
1 Introduction
7
Who Should Use this Manual
7
Purpose and Scope
7
Manual Revision
7
Symbol Conventions Used in this Manual and on Equipment
8
2 Product Description
9
Related Products and Documents
9
Products
9
Documents
10
Part Number Breakdown
10
General Specifications
11
Table 2-2: Chassis Size Codes
11
General Precautions and Safety Warnings
12
3 Installation Instructions
13
Environment
13
Unpacking
13
Mounting
13
Wiring and User Connections
13
Power Wiring
13
Control Interface and I/O Wiring
15
Table 3-3: User I/O Connections with 3460M6 Board
16
Table 3-4: User I/O Connections with 3660D1 Board
17
Typical Configurations
18
Figure 3-3: M3460R Typical Configuration with Electrolytic Capacitor Storage Bank
19
Figure 3-4: M3460R Typical Configuration with Ultracapacitor Storage Bank
20
Figure 3-5: M3460B Typical Configuration with Battery Storage Bank
21
4 Operation
23
Functional Description
23
M3460R Operation for Full Outage Protection
23
Operation Modes and Configuration
23
Normal Operation
23
Test Mode
23
I/O, Features, and Displays
24
Figure 4-1: 3460M6 Status Interface Board Layout
24
Input Terminals - 3460M6 TB7
25
Figure 4-3: 3460D5 Power Supply Board Layout (for 380V and 460V)
25
Output Terminals - 3460M6 TB5, TB6
26
Table 4-1: 3460M6 Enable Input Logic Jumper Details
26
Local I/O Power Supply - TB6 - 1, 9
28
Run Timeout Selection
28
Table 4-2: 3460M6 Status Output Signal Logic Jumper Details
28
Test Timer Selection
29
Indicators
29
Table 4-4: Test Timer Jumper Configurations
29
Fan Timer
30
Display Options
30
DC Bus Threshold Voltage Setting
32
Determining the DC Bus Threshold Voltage Setting Directly (M3460R Models)
32
Determining the DC Bus Threshold Voltage Setting Directly (M3460B Models)
33
Determining the DC Bus Threshold Voltage Setting Using the Test Mode
33
Adjusting the DC Bus Threshold Voltage Setting
34
Input Undervoltage (IUV) Level Adjustment
34
Output Undervoltage Level Adjustment
34
5 Start-Up, Maintenance and Troubleshooting
35
M3460R Start-Up / Field Test Procedure
35
M3460B Start-Up / Field Test Procedure
36
Maintenance Items
37
Capacitor Replacement Recommendations
37
Capacitor Testing Procedure
38
Cleaning
38
Fans
38
Heatsinks
38
Troubleshooting
39
Technical Help - before You Call
40
6 Engineering Data
41
Ratings
41
Table 6-5: M3460R Model Specifications for 230 – 480 VAC Systems
42
Efficiency / Power Consumption
43
Table 6-7: M3460R Model Specifications for 575 - 600 VAC Systems
43
Certifications
44
Underwriters Laboratories Listing
44
CE Conformity
44
Third Party Certifications
44
Branch Circuit Protection and Wire Sizing
44
Table 6-9: M3460R Input Power Wiring Sizes and Fusing
45
Dimensions and Mechanical Drawings
46
Figure 6-1: M3460-R10 Chassis Dimensional Outline
46
Figure 6-2: M3460-R9 Chassis Dimensional Outline
47
Figure 6-3: M3460-R11 Chassis Dimensional Outline
48
Figure 6-4: M3460-R2 Chassis Dimensional Outline
49
Figure 6-5: DD5 Digital Display Cutout and Mounting Dimensions
50
7 Appendices
51
M3460 Installation Considerations
51
Specifying an Ultracapacitor Storage Bank for Full Outage Protection with M3460R Models
51
Energy Required for Outage
53
Minimum Capacitor Bank Voltage
53
Peak Current
53
Capacitor Specifications
53
Minimum Series String
54
Available Joules
54
Steering Diode Sharing with a Bonitron M3460 Ride-Thru
55
Figure 7-1: Diode Sharing Example
56
Sag Only Installations & Circulating Currents
57
Figure 7-2: M3460R Typical Configuration Without Energy Storage
57
Figure 7-3: M3460R Typical Configuration with Current Flow
58
Figure 7-4: M3460R Typical Configuration with Ultracapacitor Storage Bank
60
Advertisement
bonitron M3460 Customer Reference Manual (68 pages)
Ride-Thru Enclosed Voltage Regulator
Brand:
bonitron
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
4
1 Introduction
7
Who Should Use this Manual
7
Purpose and Scope
7
Manual Revision
7
Symbol Conventions Used in this Manual and on Equipment
8
2 Product Description
9
Related Products and Documents
9
Products
9
Documents
10
Part Number Breakdown
10
General Specifications
11
General Precautions and Safety Warnings
12
3 Installation Instructions
13
Environment
13
Unpacking
13
Mounting
13
Wiring and User Connections
14
Power Wiring
14
Control Interface and I/O Wiring
16
Typical Configurations
20
4 Operation
25
Functional Description
25
M3460R Operation for Full Outage Protection
25
Operation Modes and Configuration
25
Normal Operation
25
Test Mode
25
DC Bus Threshold Voltage Setting
35
Determining the DC Bus Threshold Voltage Setting Directly (M3460R Models)
36
Determining the DC Bus Threshold Voltage Setting Directly (M3460B Models)
36
Determining the DC Bus Threshold Voltage Setting Using the Test Mode
36
Adjusting the DC Bus Threshold Voltage Setting
37
5 Start-Up, Maintenance and Troubleshooting
39
M3460R Start-Up / Field Test Procedure
39
M3460B Start-Up / Field Test Procedure
40
Maintenance Items
40
Capacitor Replacement Recommendations
40
Capacitor Testing Procedure
42
Cleaning
42
Fans
42
Heatsinks
42
Troubleshooting
43
Technical Help - before You Call
44
6 Engineering Data
45
Ratings
45
Efficiency / Power Consumption
47
Branch Circuit Protection and Wire Sizing
47
Dimensions and Mechanical Drawings
48
7 Appendices
53
M3460 Installation Considerations
53
Specifying an Ultracapacitor Storage Bank for Full Outage Protection with M3460R Models
53
Energy Required for Outage
55
Minimum Capacitor Bank Voltage
55
Peak Current
55
Capacitor Specifications
56
Minimum Series String
56
Available Joules
56
Steering Diode Sharing with a Bonitron M3460 Ride-Thru
57
Sag Only Installations & Circulating Currents
60
Advertisement
Related Products
bonitron M3345
bonitron M3645
bonitron M3534-I3
bonitron M3460UC
bonitron M3534R Series
bonitron M3534B
bonitron M3460D
bonitron M3460R
bonitron M3460RD
bonitron M3452-U600CK6
bonitron Categories
Control Unit
Controller
Test Equipment
Power Supply
Power distribution unit
More bonitron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL