biosystems PhD Ultra Multi Gas Detector Manuals
Manuals and User Guides for biosystems PhD Ultra Multi Gas Detector. We have
1
biosystems PhD Ultra Multi Gas Detector manual available for free PDF download: Reference Manual
biosystems PhD Ultra Reference Manual (60 pages)
Multi Gas Detector
Brand:
biosystems
| Category:
Smoke Alarm
| Size: 1 MB
Table of Contents
Table of Contents
3
Introduction
7
Signal Words
7
Warnings
8
Chapter 1 Phd Ultra Description
9
Phd Ultra Capabilities
9
Methods of Sampling
9
Multi-Sensor Capability
9
Calibration
9
Instrument Identifiers
10
Alarm Logic
10
Atmospheric Hazard Alarms
10
Sensor Overrange Alarms
10
Low Battery Alarms
10
Low Battery Alarm Settings for Nicad Battery Packs
11
Low Battery Alarm Settings for Alkaline Battery Packs
11
Other Alarms and Special Microprocessor Features
11
Combustible Sensor "Over-Limit" Alarm Latch
11
Missing Sensor
11
Needs Cal
11
Can't ID Sensor
11
Down-Scale or Negative Reading Alarms
12
Temperature out of Range
12
Other Electronic Safeguards
12
Security Beep
12
Instrument Firmware Requirement for Compatibility with the Iq System
12
Classification for Intrinsic Safety
12
Options
12
Sensors
12
Batteries
12
Nicad Battery Pack
13
Disposable Alkaline Battery Pack
13
Continuous Sample Draw Pump
13
Phd Ultra Design Components
13
Phd Ultra Accessories
14
Alkaline" Phd Ultra Detectors
14
Nicad" Phd Ultra Detectors
14
Phd Ultra Kits
14
Phd Ultra Confined Space Kits
14
Phd Ultra Value Packs
14
Chapter 2 Basic Operation
15
Operation Overview
15
Turning the Phd Ultra on
15
Start-Up Sequence
15
Other Start-Up Screens
16
Self-Adjusting" or "Correcting
16
Non-Standard Alarms
16
Needs Cal
16
Turning the Phd Ultra off
16
Operating Modes
16
Text Only Mode
16
Basic Mode
17
Technician Mode
17
Peak Readings
17
Stel Readings
17
Twa Readings
18
Runtime Screen
18
Changing Operating Modes
18
Batteries
18
Nicad Battery Pack
19
Disposable Alkaline Battery Pack
19
Low Battery Alarms
19
Low Battery Alarm Settings for Nicad Battery Packs
19
Low Battery Alarm Settings for Alkaline Battery Packs
19
Recharging Nicad Battery Packs
19
Charging Procedure with Nicad Battery Pack Installed
20
Charging the Nicad Battery Pack Separately from the Instrument
20
Cycling" Nicad Battery Packs
20
Methods of Sampling
21
Using the Hand Aspirated Sample Draw Kit
21
Continuous (Slip-On) Sample Draw Pump
21
Using the Continuous Sample Draw Pump
22
Protective "Low Flow" Shut-Downs
23
Resuming Diffusion Monitoring
23
Sample Probe Assembly
23
Changing Sample Probe Filters
23
Changing Sample Probe Tubes
23
Biosystems Eeprom Equipped "Smart Sensors
24
Identification of Type of Sensor by Instrument
24
Other Information Stored with the Sensor EEPROM
24
Sensor Replacement
24
Missing Sensor
24
Can't ID Sensor
24
Chapter 3 Calibration
25
Verification of Accuracy
25
Effect of Contaminants on Phd Ultra Sensors
25
Effects of Contaminants on Oxygen Sensors
25
Effects of Contaminants on Combustible Sensors
25
Effects of High Concentrations of Combustible Gas on the Combustible Sensor
26
Effects of Contaminants on Toxic Gas Sensors
26
Biosystems "CO Plus" Dual Purpose Carbon Monoxide / Hydrogen Sulfide Sensor
26
Relative Response of the "Co Plus" Sensor to Carbon Monoxide and Hydrogen Sulfide
27
Choosing the Correct Calibration Gas Mixture
27
Fresh Air "Zero" Calibration
27
Functional (Bump) Test
28
Auto-Calibration
28
Fresh Air "Zero" Auto-Calibration Sequence
28
Reading "Too High" or "Too Low" for Zero Adjust
29
Span" Auto-Calibration Sequence
29
Manual Calibration Procedure
30
Manual Fresh Air "Zero" through Keypad Buttons
30
Span Calibration Using Keypad Buttons
31
Chapter 4 Phd Ultra Advanced Functions
33
Phd Ultra Advanced Features Overview
33
Setting Alarm Levels
33
Alarm Adjustment Sequence
33
Viewing Current or Restoring the Factory Default Alarm Settings
34
Viewing Current Alarm Settings
34
Viewing or Restoring Factory Default Alarm Settings
34
Instrument Setup
34
Configuration Setup Choices
35
Changing the Precision of the Toxic Sensor Read-Out
35
Assigning an Instrument Identification Number
35
4"Alarm Latch" Command
35
OK Latch - Text Only Mode
36
Security Beep
36
Low Temperature Alarms
36
Operating Mode
36
Combustible Sensor Setting
36
Calibrating the Combustible Sensor in Ch Mode
37
Calibration Gas Concentration
37
Co Plus" Sensor Calibration Gas Screen
37
Temperature Compensation
38
Saving Changes and Exiting the Instrument Setup Mode
38
Re-Initializing the Phd Ultra
38
Record Keeping
39
Phd Ultra Datalogging Overview
39
Optional Datalink and Gas Detection Database Software Kit
39
Adjusting Record Keeping Parameters
40
Entering the Datalogging Adjust Mode
40
Adjusting the Sampling Interval
40
Setting the Time and Date
40
Setting the Communication Rate
41
Clear Datalogger Memory Via Push-Buttons
41
Exiting the Datalogging Adjust Mode
42
Downloading Recorded Data
42
Viewing Data
42
Entering User ID and Monitoring Location Identification Number
42
List Set: Select User / Location Information from the List
43
Custom Set: Enter New or Modify User / Location Information
43
Downloading Recorded Data to a Computer
44
Display "Service Due" Dates
44
Passcode Overview
44
Changing the Passcode
45
Enable/Disable the Passcode
45
Software / Flash Upload
45
Chapter 5 Trouble-Shooting and Repair
46
Changing Phd Ultra Sensors
46
Troubleshooting
47
Re-Booting the Microprocessor Software
47
Specific Problems
47
Problem: Unit will Not Turn on
47
Advertisement
Advertisement
Related Products
biosystems PhD Lite
biosystems Categories
Measuring Instruments
Security Sensors
Laboratory Equipment
Smoke Alarm
More biosystems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL