Sign In
Upload
Manuals
Brands
Biocare Manuals
Medical Equipment
PM-900
User Manuals: Biocare PM-900 Patient Monitor
Manuals and User Guides for Biocare PM-900 Patient Monitor. We have
1
Biocare PM-900 Patient Monitor manual available for free PDF download: User Manual
Biocare PM-900 User Manual (182 pages)
Veterinary Monitor
Brand:
Biocare
| Category:
Medical Equipment
| Size: 4 MB
Table of Contents
Table of Contents
5
Preface
13
Customer Required Reading
15
Chapter 1 Operation Safety Information
17
Safety Information
17
Influence on the Environment and Energy Sources
19
Safety Classification
19
Safety Requirements
20
Device Identifications
22
Chapter 2 Overview
23
Brief Introduction
23
Applicability
23
Contraindications
23
Configuration Composition
23
Faceplate
24
Front View
24
Side View
26
Back View
27
Modules
28
Screen Display
28
Main Interface
28
Interface Explanation
28
Shortcut Key
32
Chapter 3 Basic Operation
33
Installation
33
Unpacking and Checking
33
Environmental Requirements
33
Normal Operation Conditions
34
Operation Preparation
34
Power Supply Connection
34
Turn on
35
Sensor Connection
35
Recorder Checking
35
Monitoring
35
Turn off
35
Input Board
36
Interface Setup
37
Main Menu
38
General Setup
38
Monitor Definition
38
Screen Type Setup
38
Screen Brightness
39
Time and Date Setup
39
Audio Setup
39
Help Menu
39
Configuration Management
40
Recent Configuration Self-Recovery
40
Turning-On Default Configuration Setup
40
User Configuration Storage
40
User Configuration Deletion
41
Default Configuration Manual Restore
41
Chapter 4 Animal Management
43
Admit Animal
43
Quick Admit
43
Edit Animal Demographics
43
Discharge Animal
44
Data Management
44
Central Monitoring System
44
Chapter 5 User Interface
45
Interface Style Setup
45
Standard Interface
46
Minitrends Interface
46
Bignumerics Interface
47
Oxycrg Interface
48
View Other Bed Interface
49
Lead Half Screen
51
Lead Full Screen
52
Chapter 6 Parameter Monitoring
53
Ecg
53
ECG Measuring Principle
53
Definition of ECG Monitoring
54
ECG Intended Use
54
Safety Information
54
Monitoring Procedures
55
ECG Display
57
ECG Setup
58
ST Analysis
59
Arrhythmia Monitoring
61
Arrhythmia Alarm
62
ECG Relearn
67
Resp
67
Resp General Description
67
Resp Display
68
Placing Respiration Electrodes
68
Resp Setup
68
PR General Description
70
PR Source
70
Alarm Source Setup
70
Pulse Volume Setup
71
Spo 2
71
Spo General Description
71
Safety Information
72
Monitoring Steps
73
Spo 2 Setup
74
Influencing Factors of Measure
75
Nibp
76
NIBP General Description
76
Safety Information
77
Measure Restriction
79
Measure Mode
79
Measure Procedure
79
NIBP Display
80
NIBP Setup
81
NIBP Leakage Test
83
NIBP Accuracy Test
84
Temp
85
General Description
85
Safety Information
86
Measure Procedure
86
Measure Display
87
Temp Unit Setup
87
Alarm Setup
87
IBP (Optional)
87
General Description
87
Safety Information
87
Monitoring Steps
88
IBP Display
89
IBP Setup
89
Sensor Zero-Calibration
90
CO (Optional)
91
General Description
91
Side-Stream CO 2 Module
92
Main-Stream CO 2 Module
94
CO Setup
96
Zero
98
Calibrate
99
Influencing Factors of Measure
100
Faulty Handling
100
Emissions
100
Chapter 7 Alarm
101
General Description
101
Alarm Type
101
Alarm Level
101
Alarm Mode
101
Alarm Setup
102
Global Alarm Interface
102
Parameter Alarm Setup
103
Alarm Configuration
104
Alarm Pause
106
Alarm Silence
106
Alarm Detection and Counter Measures
107
Other Bed Alarm
107
Other Bed Alarm Auto Prompting
107
Other Bed Alarm Silence
107
Chapter 8 Freeze and Review
109
Enter Freeze
109
Remove Freeze
109
Record Frozen Waveforms
109
Review
110
Review Window
110
Graphic Trends
110
Tabular Trends
112
Events
113
NIBP List
115
Long ECG
116
Chapter 9 Calculations
117
General Description
117
Medication Calculation
117
Hemodynamic Calculation
120
Review
120
Output
121
Renal Function Calculation, Oxygenation Calculation, Ventilation Calculation
122
Chapter 10 Recording (Optional)
123
Recorder
123
Record Setup
123
Start and Stop Recording
124
Install Recording Paper
125
Cleaning of the Thermal Print Head
125
Chapter 11 Other Functions
127
Power-On
127
Colors of the Measured Physiological Parameters
127
Manual Event
127
Defaults
128
System State Indicator
128
Standby Mode
128
Chapter 12 Battery
129
General Description
129
Battery Installation
130
Battery Recycling
131
Chapter 13 Cleaning and Maintenance
133
Cleaning of Monitor
133
Disinfecting of Monitor
133
Fan Cleaning
134
Storage of Monitor
134
Transport
134
Inspection of Monitor
134
Chapter 14 Maintenance
135
Safety Information
135
NIBP Accuracy Test
135
NIBP Overpressure Test
135
NIBP Leakage Test
135
User Maintain
136
Demo Model
137
Monitor System Information
138
Chapter 15 Troubleshooting and Solutions
139
Check before Use
139
The Monitor Cannot be Turned on
139
The Monitor Cannot be Shut down Normally with ON/OFF Switch
139
No Display on Screen
140
Interference to ECG Signal too High or Baseline too Coarse
140
No Measured Result of NIBP
140
No Measured Result of Spo
140
Measure Result of Etco
140
Is Low (Optional)
140
The Sound of Sidestream CO
141
Pump Becomes High (Optional)
141
Body Temperature Without Numerical Value or Inaccurate Readings
141
Appendix A Packaging and Accessories
143
Packaging
143
Accessories
143
Appendix B Product Specifications
145
Safety Specifications
145
Product Classification
145
Environment Specifications
146
Power Specifications
146
Physical Specifications
146
Hardware Specifications
146
Data Storage
148
Wireless Network (Optional)
149
Measuring Specifications
149
ECG Monitoring
149
Respiration (Resp) Monitoring
152
Spo 2 Monitoring
153
PR Specifications
153
NIBP Monitoring
154
Temperature (Temp) Monitoring
156
IBP Monitoring
156
Monitoring (Optional)
157
Recorder Specifications (Optional)
160
Appendix C Alarm Information
161
Appendix D Factory Default Setup
167
Animal Demographics
167
Alarm
167
Alarm Limit
168
Screen Setup
170
User Maintain
170
Ecg
171
Nibp
173
Spo
173
Resp
173
Ibp
174
CO (Optional)
174
Other Setup
175
Appendix E EMC- Guidance and Manufacture's Declaration
177
Guidance and Manufacture's Declaration-Electromagnetic Emissions for All EQUIPMENT and SYSTEMS
177
Guidance and Manufacture's Declaration-Electromagnetic Immunity for All EQUIPMENT and SYSTEMS
177
Recommended Separation Distance between Portable and Mobile RF Communications Equipment and the EQUIPMENT or SYSTEM for EQUIPMENT or SYSTEM that Are Not LIFE-SUPPORTING
180
Advertisement
Advertisement
Related Products
Biocare Petrust Plus
Biocare iE 101
Biocare iE 3
Biocare iE 300
Biocare iE 6
Biocare iM 12
Biocare iM 15
Biocare iM 8
Biocare Categories
Medical Equipment
Blood Pressure Monitor
Blood Glucose Meter
Thermometer
Scanner
More Biocare Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL