Sign In
Upload
Manuals
Brands
BEKA Manuals
Measuring Instruments
BA337NE
BEKA BA337NE Manuals
Manuals and User Guides for BEKA BA337NE. We have
2
BEKA BA337NE manuals available for free PDF download: Instruction Manual, Application Manual
BEKA BA337NE Instruction Manual (47 pages)
Rugged one input Ex nA and Ex tc Rate Totaliser
Brand:
BEKA
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Description
5
2 Operation
5
Initialisation
5
Controls
6
Displays
6
Display Over-Range
6
3 Certification
7
ATEX Ex Na Certification
7
Zones, Gas Groups & T Rating
7
Special Conditions for Safe Use
7
Power Supply
7
Pulse Input
7
Remote Reset Terminals
8
Certification Label Information
8
4 System Design for Hazardous Areas
8
Power Supply
8
Pulse Input
9
Input Switching Thresholds
10
Switch Contact Input
10
Open Collector Input
10
2-Wire Proximity Detector Input
10
Magnetic Pick-Off Input
10
Voltage Pulse Input
10
Remote Reset
10
5 Installation
11
Location
11
Installation Procdedure
11
Rate Totaliser Earthing
12
Emc
12
Scale Card
12
6 Configuration and Calibration
14
Accessing Configuration Functions
14
Summary of Configuration Functions
14
Rate Totaliser Function: Function
17
Input: Input
17
Input Type: Inp . Type
17
Debounce: Debounce
20
Display Update Interval: Update
20
Upper Display: Di5P-1
20
Lower Display: Di5P-2
20
Position of Decimal Points: Dp
21
Flowmeter K-Factor: Factor
21
Total Scale Factor: 5Cale . T
21
Rate Scale Factor: 5Cale . R
21
Timebase: T-Ba5E
22
Display Filter: Filter
22
Clip-Off: Clp off
22
Local Reset: Loc Clr
23
Local Total Reset: Clr Tot
23
Local Grand Total Reset: Clr Gtot
23
Grand Total Reset from Configuration Menu: Clr Gtot
23
Security Code: Code
23
7 Lineariser
25
Flowmeter Specification
25
Summary of Lineariser Configuration Functions
25
Add a Segment: Add
27
Remove a Segment: del
27
Input Frequency: Pul5Efre
28
Lineariser Error Messages
28
8 Configuration Example
29
Configuration Procedure
29
9 Maintenance
32
Fault Finding During Commissioning
32
Fault Finding after Commissioning
32
Servicing
32
Routine Maintenance
32
Guarantee
33
Customer Comments
33
10 Accessories
33
Scale Card
33
Tag Information
33
Backlight
33
Alarms
34
Solid State Output
34
Alarm Enable: Enbl
36
Type of Alarm: Type
36
Setpoint Adjustment: 5P1X and 5P2X
36
Alarm Function: Hi. lo
36
Alarm Output Status: No. N C
36
Hysteresis: H5Tr
36
Alarm Delay: Dela
36
Alarm Silence Time: 5Il
37
Access Setpoint: Ac5P
38
Pulse Output
39
Ex Na Certification
40
Enable Pulse Output: Enbl
41
Source of Pulse Output: 5Ource
41
Divide Output Pulse Frequency: Divide
41
Output Pulse Width: Duration
41
Pulse Storage
42
4/20Ma Output
42
Configuration
43
4/20Ma Output: 4-20Op
43
Enable 4/20Ma Output: Enbl
43
Select Rate or Total Source: 4-20Type
43
Advertisement
BEKA BA337NE Application Manual (16 pages)
Externally powered pulse input Rate Totalisers
Brand:
BEKA
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Table of Contents
1
1 Introduction
6
2 Selecting a Model
6
Mounting
6
Field Mounting
6
Panel Mounting
7
Location
7
General Purpose Applications
7
Explosive Atmosphere Applications
7
Two Input Models
8
Operating Temperature
8
3 Rate Totaliser Function
8
4 Rate Totaliser Configuration
9
Flowmeter K-Factor
9
Total Scale Factor
9
Rate Scale Factor
9
Resolution
11
5 Linearisation
12
6 Pulse Output
12
7 Optional 4/20Ma Output
13
8 Optional Dual Alarm Outputs
13
9 Slide-In Scale Card
13
10 Configuration Examples
14
11 Additional Information
16
Advertisement
Related Products
BEKA BA334E
BEKA BA334G
BEKA BA334NG
BEKA BA337E
BEKA BA338E
BEKA BA337E-SS
BEKA BA338C
BEKA BA334ND
BEKA BA334D
BEKA BA304ND
BEKA Categories
Measuring Instruments
Monitor
Water Pump
Cash Counter
Transmitter
More BEKA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL