Sign In
Upload
Manuals
Brands
Argo Manuals
Air Conditioner
ASS56MH
Argo ASS56MH Manuals
Manuals and User Guides for Argo ASS56MH. We have
2
Argo ASS56MH manuals available for free PDF download: Installation Instructions Manual
Argo ASS56MH Installation Instructions Manual (130 pages)
MULTISET System Air Conditioner
Brand:
Argo
| Category:
Air Conditioner
| Size: 4 MB
Table of Contents
Table of Contents
6
Installation Instructions
1
Important
2
Please Read before Starting
2
Check of Density Limit
3
Precautions for Installation Using New Refrigerant
4
PM Page
6
Table of Contents
6
PM Page
7
General
8
Tools Required for Installation (Not Supplied)
8
Accessories Supplied with Unit
8
Type of Copper Tube and Insulation Material
8
Additional Materials Required for Installation
8
Tubing Size
13
Straight Equivalent Length of Joints
13
Additional Refrigerant Charge
14
Tubing Length
14
Check of Limit Density
15
Installing Distribution Joint
15
Optional Distribution Joint Kit
16
Optional Ball Valve Kit
16
Recommended Location of Ball Valves
18
Example of Tubing Size Selection and Refrigerant Charge Amount
19
Selecting the Installation Site
21
Indoor Unit
21
Outdoor Unit
22
Air Discharge Chamber for Top Discharge
23
Installing the Unit in Heavy Snow Areas
23
Precautions for Installation in Heavy Snow Areas
23
Dimensions of Air-Discharge Chamber
24
Dimensions of Outdoor Unit with Air-Discharge Chamber (Field Supply)
24
Dimensions of Snow Ducting
26
Dimensions of Outdoor Unit with Snow-Proof Vents (Field Supply)
26
How to Install the Indoor Unit
29
I 1-Way Air Discharge Semi-Concealed Type (AS1S Type)
29
Suspending the Indoor Unit
29
Placing the Unit Inside the Ceiling
30
Installing the Drain Piping
31
Checking the Drainage
33
I 1-Way Air Discharge Semi-Concealed Slim Type (ASBS Type)
34
Suspending the Indoor Unit
34
Placing the Unit Inside the Ceiling
35
Installing the Drain Piping
36
Checking the Drainage
37
I 2-Way Air Discharge Semi-Concealed Type
39
(AS2S Type)
39
Suspending the Indoor Unit
39
Placing the Unit Inside the Ceiling
40
Installing the Drain Piping
40
Table of Contents
41
Checking the Drainage
42
(ASS Type)
43
I 4-Way Air Discharge Semi-Concealed Type
43
Preparation for Suspending
43
Suspending the Indoor Unit
43
Placing the Unit Inside the Ceiling
44
Note
45
(1/100 or More) and that There Are no Water Traps
45
Installing the Drain Piping
45
Packing and Drain Pipe Insulator Around the Pipe
45
(Fig. 3-43)
45
Make Sure the Drain Pipe Has a Downward Gradient
45
Checking the Drainage
46
If It Is Necessary to Increase the Height of the Drain Pipe, the Section Directly after the Con- Nection Port Can be Raised a Maximum of
46
CM or Less
46
CM or Less (as Short as Possible)
46
Drain Water to Flow Backward and Leak When the
46
Fig
46
Support Pieces
46
Upward Gradient Prohibited
46
Fig
47
I Wall-Mounted Type (AWS Type)
47
Removing the Rear Panel from the Unit
47
Selecting and Making a Hole
47
Installing the Rear Panel Onto the Wall
48
Removing the Grille to Install the Indoor Unit
48
Preparing the Tubing
49
Shaping the Tubing
49
Installing the Drain Hose
50
I Ceiling-Mounted Type (ACS Type)
51
Required Minimum Space for Installation and Service
51
Suspending the Indoor Unit
52
Duct for Fresh Air
55
Installing the Drain Piping
55
Shaping the Tubing
55
Required Minimum Space for Installation and Service
58
Suspending the Indoor Unit
59
Installing the Drain Piping
60
Checking the Drainage
61
Increasing the Fan Speed
62
I Concealed-Duct High Static Pressure Type
63
(ADPS Type)
63
Required Minimum Space for Installation and Service (73, 106, 140 Type)
63
Fig
64
Suspending the Indoor Unit
64
Installing the Drain Piping
65
Drain Pan
65
Min. 1/100
65
Caution for Ducting Work
66
Fig
66
Concealed Floor-Standing Type (AFNS Type)
67
Dimensions and Part Names
67
Length AB
67
Table
67
I Floor-Standing Type (AFS Type)
67
Required Minimum Space for Installation and Service
67
Installing the Refrigerant Tubing
69
Removing and Attaching the Front Panel (Floor-Standing Type)
69
Installing the Drain Piping
71
Installing the Remote Controller
71
How to Install the Outdoor Unit
72
Installing the Outdoor Unit
72
Drainage Work
72
Routing the Tubing and Wiring
72
Electrical Wiring
73
General Precautions on Wiring
73
Recommended Wire Length and Wire Diameter for Power Supply System
73
Wiring System Diagrams
74
How to Install the Remote Controller (Optional Part)
77
When Using a Wall Box for Flush Mounting
77
Basic Wiring Diagram
78
Wiring System Diagram for Group Control
78
Switching the Room Temperature Sensors
80
Connecting to a Ventilation Fan
80
Wiring the Remote Controller
81
How to Process Tubing
82
Connecting the Refrigerant Tubing
82
Connecting Tubing between Indoor and Outdoor Units
83
Insulating the Refrigerant Tubing
84
Taping the Tubes
85
Finishing the Installation
85
Air Purging
86
I Air Purging with a Vacuum Pump (for Test Run) Preparation
86
How to Install the Ceiling Panel
89
I 1-Way Air Discharge Semi-Concealed Type
89
(AS1S Type)
89
Installing the Ceiling Panel
89
How to Use the Stoppers
89
I 1-Way Air Discharge Semi-Concealed Slim Type
90
(ASBS Type)
90
Installing the Ceiling Panel
90
I 2-Way Air Discharge Semi-Concealed Type
92
(AS2S Type)
92
Before Installing the Ceiling Panel
92
Installing the Ceiling Panel
93
When Removing the Ceiling Panel for Servicing
93
I 4-Way Air Discharge Semi-Concealed Type (ASS Type)
94
Before Installing the Ceiling Panel
94
Installing the Ceiling Panel
95
Wiring the Ceiling Panel
96
How to Attach the Corner & Air Intake Grille
96
Checking after Installation
97
When Removing the Ceiling Panel for Servicing
97
Adjusting the Auto Flap
97
Test Run
98
Preparing for Test Run
98
Test Run Procedure
99
Items to Check before the Test Run
99
Outdoor Unit PCB Setting
100
Auto Address Setting
102
Caution for Pump down
109
Meaning of Alarm Messages
109
How to Install the Wireless Remote Controller Receiver
111
I REM HLASS for 4-Way Cassette (ASS Type)
111
Installing the Receiver Unit
111
Accessories/Wiring the Receiver Unit
112
Accessories
112
Precautions on Simultaneous Installation of Wired Remote Controller and Wireless Remote Controller
112
Wiring the Receiver Unit
112
How to Use the Test Run Setting
113
I REM HLACS for Ceiling Mounted (ACS Type)
114
Installing the Receiver Unit
114
1 Receiver Unit 1
115
Accessories Supplied with Unit
115
Precautions on Simultaneous Installation of Wired Remote Controller and Wireless Remote Controller
115
AAA Alkaline Battery
115
Parts Q'ty
115
Tapping Screw 4
115
Wiring the Receiver Unit
115
How to Use the Test Run Setting
116
1-Way Type (AS2S, ASBS Type)
117
I REM HLAS2BS for 2-Way and High Ceiling
117
Installing the Control Unit
117
Installing the Display
117
Installing the Control Unit
118
Installing the Display
118
Accessories
119
By Installing a Wired Remote Controller, the Wireless
119
Precautions on Simultaneous Installation of Wired Remote Controller and Wireless Remote Controller
119
2 Remote
119
Control Unit
119
Remote Control Holder
119
Wiring the Receiver Unit
119
How to Use the Test Run Setting
121
Accessories Supplied with Separate
122
Receiver Unit
122
How to Install the Separate Receiver Unit
122
The Remote Controller will be Dam- Aged if High Voltage
123
I REM HL for AS1S, ADS, ADPS, AFS, AFNS Type
122
Important Information for Installation of
122
Separate Receiver Unit
122
Wiring the Separate Receiver Unit
125
Important Information for Installation of
126
Separate Receiver Units
126
Test Run Setting
127
6 Clamp
119
G Connection Diagram
119
Indoor Unit
119
Special Remarks
128
I DC Fan Tap Change Procedure for 4-Way
128
Markings for Directive 97/23/Ec(Ped)
129
Ec(Ped)
129
Advertisement
Argo ASS56MH Installation Instructions Manual (140 pages)
Multisset system DC Inverter 2-Way R410A
Brand:
Argo
| Category:
Air Conditioner
| Size: 12 MB
Table of Contents
Table of Contents
6
Installation Instructions
1
Outdoor Units
1
Important
2
Please Read before Starting
2
Check of Density Limit
3
Precautions for Installation Using New Refrigerant
4
New Refrigerant R410A Cannot be Used for Earlier Models
5
AM Page
6
Table of Contents
6
AM Page
7
General
8
Tools Required for Installation (Not Supplied)
8
Accessories Supplied with Unit
8
Type of Copper Tube and Insulation Material
8
Additional Materials Required for Installation
8
Tubing Size
13
Straight Equivalent Length of Joints
14
Additional Refrigerant Charge
14
System Limitations
15
Tubing Length
16
Check of Limit Density
17
Installing Distribution Joint
17
Optional Distribution Joint Kits
18
Optional Ball Valve Kits
20
Recommended Location of Ball Valves
23
Example of Tubing Size Selection and Refrigerant Charge Amount
24
Selecting the Installation Site
26
Indoor Unit
26
Outdoor Unit
27
Shield for Horizontal Exhaust Discharge
28
Installing the Outdoor Unit in Heavy Snow Areas
28
Precautions When Installing in Heavy Snow Areas
28
Dimensions of Wind Ducting
29
Dimensions of Snow Ducting
31
How to Install the Indoor Unit
33
1-Way Air Discharge Semi-Concealed Type (AS1S Type)
33
Suspending the Indoor Unit
33
Placing the Unit Inside the Ceiling
34
Installing the Drain Piping
35
Checking the Drainage
37
1-Way Air Discharge Semi-Concealed Slim Type (ASBS Type)
38
Suspending the Indoor Unit
38
Placing the Unit Inside the Ceiling
39
Installing the Drain Piping
40
Checking the Drainage
41
2-Way Air Discharge Semi-Concealed Type
43
(AS2S Type)
43
Suspending the Indoor Unit
43
Placing the Unit Inside the Ceiling
44
Installing the Drain Piping
44
Checking the Drainage
46
4-Way Air Discharge Semi-Concealed Type (ASS Type)
47
Preparation for Suspending
47
Suspending the Indoor Unit
47
Placing the Unit Inside the Ceiling
48
Installing the Drain Piping
49
Checking the Drainage
50
Wall-Mounted Type (AWS Type)
51
Removing the Rear Panel from the Unit
51
Selecting and Making a Hole
51
Installing the Rear Panel Onto the Wall
52
Removing the Grille to Install the Indoor Unit
52
Preparing the Tubing
53
Shaping the Tubing
53
Installing the Drain Hose
54
Ceiling-Mounted Type (ACS Type)
55
Required Minimum Space for Installation and Service
55
Suspending the Indoor Unit
56
Duct for Fresh Air
59
Shaping the Tubing
59
Installing the Drain Piping
59
Required Minimum Space for Installation and Service
62
Suspending the Indoor Unit
63
Installing the Drain Piping
64
Checking the Drainage
65
Increasing the Fan Speed
66
Table
67
(ADPS Type)
67
Concealed-Duct High Static Pressure Type
67
Required Minimum Space for Installation and Service (73, 106, 140 Type)
67
It Is Recommended that Space Is Provided
67
The Minimum Space for Installation and Service Is
67
This Air Conditioner Is Usually Installed above the Ceiling
67
Required Minimum Space for Installation and Service (224, 280 Type)
68
Suspending the Indoor Unit
69
A (Length)
69
Installing the Refrigerant Tubing
70
Installing the Drain Piping
71
Min. 1/100
71
Caution for Ducting Work
72
Type
69
Fig
72
Increasing the Fan Speed (280 Type Only)
73
Electrical Component Box (Hole)
73
Concealed Floor-Standing Type (AFNS Type)
74
Dimensions and Part Names
74
Min
74
Floor-Standing Type (AFS Type)
74
Required Minimum Space for Installation
74
Installing the Refrigerant Tubing
76
Removing and Attaching the Front Panel (Floor-Standing Type)
76
Installing the Drain Piping
78
Installing the Remote Controller
78
How to Install the Outdoor Unit
79
Electrical Wiring
81
General Precautions on Wiring
81
Recommended Wire Length and Wire Diameter for Power Supply System
81
Wiring System Diagrams
82
How to Install the Remote Controller (Optional Part)
85
When Using a Wall Box for Flush Mounting
85
Basic Wiring Diagram
86
Wiring System Diagram for Group Control
86
Switching the Room Temperature Sensors
88
Connecting to a Ventilation Fan
88
Wiring the Remote Controller
89
Meanings of Alarm Messages
90
How to Process Tubing
93
Connecting the Refrigerant Tubing
93
Connecting Tubing between Indoor and Outdoor Units
94
Insulating the Refrigerant Tubing
95
Taping the Tubes
96
Finishing the Installation
96
Air Purging
97
Air Purging with a Vacuum Pump (for Test Run) Preparation
97
How to Install the Ceiling Panel
100
1-Way Air Discharge Semi-Concealed Type (AS1S Type)
100
Installing the Ceiling Panel
100
How to Use the Stoppers
100
1-Way Air Discharge Semi-Concealed Slim Type (ASBS Type)
101
Installing the Ceiling Panel
101
2-Way Air Discharge Semi-Concealed Type (AS2S Type)
103
Before Installing the Ceiling Panel
103
Installing the Ceiling Panel
104
When Removing the Ceiling Panel for Servicing
104
4-Way Air Discharge Semi-Concealed Type (ASS Type)
105
Before Installing the Ceiling Panel
105
Installing the Ceiling Panel
106
Wiring the Ceiling Panel
107
How to Attach the Corner & Air Intake Grille
107
Checking after Installation
108
When Removing the Ceiling Panel for Servicing
108
Adjusting the Auto Flap
108
Test Run
109
Preparing for Test Run
109
Test Run Procedure
110
Items to Check before the Test Run
110
Main Outdoor Unit PCB Setting
111
Sub Outdoor Unit PCB Setting
113
Auto Address Setting
114
Caution for Pump down
121
How to Install the Wireless Remote Controller Receiver
122
REM HLASS for 4-Way Cassette (ASS Type)
122
Installing the Receiver Unit
122
Accessories/Wiring the Receiver Unit
123
Accessories
123
Precautions on Simultaneous Installation of Wired Remote Controller and Wireless Remote Controller
123
Wiring the Receiver Unit
123
How to Use the Test Run Setting
124
Installing the Receiver Unit
125
REM HLACS for Ceiling Mounted (ACS Type)
125
Parts Q'ty
126
AAA Alkaline Battery
126
Accessories Supplied with Unit
126
Precautions on Simultaneous Installation of
126
Wired Remote Controller and Wireless
126
Wiring the Receiver Unit
126
1 Receiver Unit 1
126
5 Tapping Screw 4
126
Remote Controller
127
How to Use the Test Run Setting
127
REM HLAS2BS for 2-Way and High Ceiling
128
1-Way Type (AS2S, ASBS Type)
128
Installing the Display
128
Installing the Control Unit
128
Installing the Display
129
Installing the Control Unit
129
Wiring the Receiver Unit
130
Precautions on Simultaneous Installation of
130
Remote Controller
130
2 Remote
130
Control Unit
130
Control Holder
130
How to Use the Test Run Setting
132
REM HL for AS1S, ADS, ADPS, AFS, AFNS Type
133
Accessories Supplied with Separate Receiver Unit
133
Important Information for Installation of
133
Separate Receiver Unit
136
Wiring the Separate Receiver Unit
136
Important Information for Installation of
137
Separate Receiver Units
137
Test Run Setting
138
6 Clamp
130
Special Remarks
139
DC Fan Tap Change Procedure for 4-Way
139
Advertisement
Related Products
Argo ASS56
Argo ASS56PH
Argo ASS71
Argo ASS125
Argo ASS22MH
Argo ASS36MH
Argo ASS73MH
Argo ASS140MH
Argo ASS140M
Argo ASS36PH
Argo Categories
Air Conditioner
Heater
Utility Vehicle
Dehumidifier
Offroad Vehicle
More Argo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL