Sign In
Upload
Manuals
Brands
Areva Manuals
Desktop
MiCOM C264C
Areva MiCOM C264C Manuals
Manuals and User Guides for Areva MiCOM C264C. We have
1
Areva MiCOM C264C manual available for free PDF download: Technical Manual
Areva MiCOM C264C Technical Manual (366 pages)
Bay Computer
Brand:
Areva
| Category:
Desktop
| Size: 7 MB
Table of Contents
Table of Contents
7
Introduction
9
Health and Safety
10
Installing, Commissioning and Servicing
10
Decommissioning and Disposal
12
Technical Specifications for Safety
13
Handling of Electronic Equipments
14
Packing and Unpacking
15
Guaranties
16
Copyrights & Trademarks
17
Warnings Regarding Use of T&D Eai Products
18
Table of Contents
21
1 INTRODUCTION to Micom
23
2 INTRODUCTION to Micom GUIDES
24
Chapters Description
24
Chapter Safety (SA)
24
Chapter Introduction (IT)
24
Chapter Functional Description (FT)
24
Chapter Technical Data (TD)
24
Chapter Communications (CT)
24
Chapter HMI, Local Control and User Interface (HI)
24
Chapter Installation (IN)
24
Chapter Hardware Description (HW)
24
Chapter Commissioning (CM)
25
Chapter Commissioning Record Sheet (RS)
25
Chapter Logic Diagrams (LG)
25
Chapter Applications (AP)
25
Chapter Settings (ST)
25
Chapter Maintenance, Fault Finding, Repairs (MF)
25
Chapter Problem Analysis (PR)
25
Chapter Lexical (LX)
25
Operation Guide
25
Technical Guide
25
3 INTRODUCTION to Micom APPLICATIONS
26
Micom Computers
26
Applications and Scope
26
Technical Data
29
Table of Contents
31
1 Scope of the Document
33
2 Conformity
33
3 General Data
33
Design
33
Installation Position
33
Degree of Protection
33
Weight
33
Dimensions and Connections
33
Terminals
33
Creepage Distances and Clearances
34
Trademarks
34
4 Ratings
35
Auxiliary Voltage
35
Digital Inputs
35
Digital Outputs
36
Dou200
36
Ccu200
36
Biu241
37
Analogue Inputs
37
CT/VT Inputs
37
Currents
37
Voltages
38
A/D Converter
38
5 Burdens
39
Auxiliary Voltage
39
Digital Inputs
39
Digital Outputs
39
Dou200
39
Ccu200
40
Analogue Inputs
40
CT / VT Inputs
40
Currents
40
Functional Description
47
Table of Contents
49
1 Scope of the Document
53
Software Features
53
2 Direct Process Interface
55
Input Check
55
Output Check
55
Time Tagging
55
3 Micom C264/C264C MANAGEMENT
56
Mode Management
56
Operating Mode Management
56
Redundancy Mode Management
56
Database Management
56
Self Tests
56
Time Management
57
External Clock
57
Clock Message from a SCADA Gateway
57
System Master Clock
58
Time Set by an Operator
58
4 Communications
59
Telecontrol Bus
59
Station Bus
60
Legacy Bus
60
Sbus Protocol
61
UCA2 Exchanges
61
UCA2 Supported Common Class
61
UCA2 Controls
61
5 Direct Process Access
62
Digital Input Acquisition (DI)
62
Analogue Input Acquisition (AI)
62
Counters Acquisition (CT)
62
Digital Measurement (DM)
62
Digital Outputs (DO)
62
6 Data Processing
63
Binary Input Processing
63
Binary Input Acquisition
63
Binary Input Definition
63
Processing of Single Point Status
63
Processing of Double Point Status
64
Group Processing
65
Processing of Multi Point Status
65
Measurement Input Processing
66
Analogue Processing
66
CT/VT Additional Processing
67
Digital Measurement Processing
67
Accumulator Input Processing
67
7 Control Sequences
68
Type of Control Sequences
68
Control Sequences Checks
68
Operational Modes
69
Interlocking
69
Control Bypass
69
HV Control Sequences
70
Control of Circuit Breaker
70
Control of Isolator
70
Transformer Control Sequence
70
8 Automation
71
Build-In Automation Functions
71
Synchrocheck
71
Auto-Recloser (AR)
73
Trip Circuit Supervision
74
Automatic Voltage Regulation (AVR)
75
Fast Automation (PSL)
77
Settable Inputs of the PSL
79
Timers
79
Programmable Gates
81
Configurable Automation (PLC)
81
9 User Interface
83
Front Panel
83
Led's Management
84
Local Control Display
84
Local/Remote Push-Button
84
Front Serial Link
84
10 Records
85
Permanent Records Storage
85
Data Storage
85
Fast Waveform Recording
85
Disturbance Recording
86
Non-Permanent Data Storage
88
Events
88
Alarm Function
88
Table of Contents
91
1 Scope of the Document
93
2 Hardware Description
93
Components
93
Hardware Overview
94
Micom C264C
95
Hardware Presentation
95
Modularity
96
I/O Capabilities
97
Micom C264
98
Hardware Presentation
98
Modularity
99
Permissible Configurations
100
I/O Capabilities
100
Modules Description
101
Power Auxiliary Supply and Legacy Ports Board - BIU241
101
Central Processing Unit and Base Communications Board - CPU260
104
Digital Inputs Unit - DIU200
106
Digital Outputs Unit - DOU200
107
Circuit Breaker Control Unit - CCU200
108
Analogue Input Unit - AIU200
109
Transducerless Measurements Unit - TMU200
110
Front Panel - GHU240
111
Connections C264/En Co/A14 Micom C264/C264C Page 1/32 Content
115
1 Scope of the Document
117
2 Connector Blocks
118
I/O Connector Block
118
CT/VT Connector Block
119
Serial Communications Connections
120
Optical Communications Connections
121
Ethernet-Based Communications Connections
122
3 Connection of the Protective (Earth Conductor)
123
Earthing
123
Cable Fitting
123
4 Connection Diagrams for each I/O Boards
126
Power Auxiliary Supply and Legacy Ports Board - BIU241
126
Central Processing Unit - CPU260
129
Digital Inputs Module - DIU200
135
Digital Outputs Module - DOU200
137
Circuit Breaker Control Unit - CCU200
139
Analogue Input Module - AIU200
141
Transducerless Measurements Unit Module -TMU200
143
Front Panel
145
Table of Contents
149
1 Scope of the Document
151
2 Requirement
151
Micom C264
151
Personal Computer
152
Communication Wiring
152
3 Delivery Reception
153
Packing Inspection and Opening
153
Delivery Form Checking
153
4 Mechanical Mounting
154
Front Panel Removal
154
Rack Mounting
154
Front Panel Reinstall
154
5 Wiring Installation
155
General Wiring
155
Power Supply Wiring
155
I/O Board Wiring
155
6 POWER up DELIVERED Micom C264
156
7 Setting Computer
156
Checking Default Settings: P Command
156
Settings to Enter
157
Input New Settings: C Command
157
Checking Communication Setting
158
Installing New Software Version
158
8 Downloading Database
159
Checking Connection
159
Loading DB under SMT
159
Download DB Unto C264
159
Switch to Downloaded Data Base
159
9 After Computer Installation
160
10 Software Installation Procedure on the Host Pc
160
Table of Contents
169
1 Scope of the Document
171
2 Requirements
171
3 Computer Definitions
172
Kind of Computers
172
Adding a Computer
172
Default Components
173
Adding Objects to the Computer Component
174
Computer's Component Relations
175
Standard Relation Definitions
175
Right Relations
175
Redundancy Relation
175
Computer Boards General
176
Computer Specific Board
177
4 Computer Attributes
178
General
178
Binary Input (BI) Filtering
178
Counter Attributes
180
5 Computer Profiles
181
Profile Definition
181
Profile Location
182
Profiles of SPS, DPS, MPS
182
General
182
State Labels
183
State Treatment
184
Interlocking
184
Alarms
185
Profile of Measurement Values
185
General
185
State Labels
186
Interlocking
186
Alarms
187
Mean Value
187
Profile of Counter
188
General
188
State Labels
188
6 Site
189
Bay Specific
189
Models
189
Build-In Functions
189
Data Point
189
7 Substation Control System
190
Computer System Information
190
UCA2 Mapping
191
Legacy Bus (L-BUS)
191
Configure a Physical Port
191
LBUS Communication
194
IED on Legacy Bus
195
IED on T103
196
IED on Modbus
205
Telecontrol Bus (T-BUS)
210
Adding a SCADA Protocol
210
Configure a Physical Port
211
TBUS Communication
212
System Data Information
216
SCADA Communication Addresses
217
SCADA Link Addresses
218
8 Use Cases
220
Standalone Computer
220
Bay Computer
220
PLC Computer
220
9 Application Cases
220
Consignment of a Data Point
220
Transmission of GOOSE
220
Table of Contents
223
1 Scope of the Document
225
Tree Panel Navigation
225
Tree Panel Organisation
226
2 Configuration of View Panels
227
Bay Display
227
Communication Display
227
Devices Display
228
Counters
228
Measurements
229
Transformer Tap Position
229
Parameters/Hmi Panels
230
Bay Panel
230
Display Options Bay Panel
231
Parameters/Treatment Panels
233
Synchrocheck
233
Serial Communication
234
Measurements Acquisition
235
Table of Contents
239
1 Scope of the Document
241
2 Plant Data Interface
241
Digital Input Treatment
241
DI Treatment Main Parts
241
Digital Input Filtering Principle
241
DI Debouncing & Filtering
242
Toggling of Binary Input
242
Analogue Input Treatment
243
Principle
243
Binary Input Processing
243
Double Point Processing
244
Multiple Points Processing
244
HV Three Phases Breaker
244
Digital Output Treatment
244
Measurement Input Processing
245
Counters Input Processing
245
3 Generic Control Sequences
246
Generic Control Checks
247
Generic Modes Control
249
Selection Control Sequence
250
Execution Control Sequence
251
Execution Control Sequence for SBO Many Mode
252
Unselection Phase for SBO Many Mode
253
Circuit Breaker
254
Ied
255
Disconnectors Device
255
Transformers
255
4 Device Control Sequences
254
5 Slow Configuration Automation (Plc)
256
6 Fast Configurable Automation (Psl)
256
Table of Contents
265
1 Scope of the Document
267
2 Scp Communication
267
Communication on Station Bus
267
Finality
267
Inputs
267
Outputs
268
Supported Services
268
Supported Data Objects
269
3 Scada Communication
271
Overview
271
SCADA Common Functionality
271
Interface
271
Behaviour and Specific Treatments
274
Data Sent to SCADA
276
Data Sent to Micom C264
278
DNP 3.0 Communication
279
Finality
279
Interface
279
Configuration
283
MODBUS Communication
284
4 Ied Communication
285
IED Common Functionality
286
Interface
286
Behaviour
288
Data Received from Ieds
292
Data Sent to Ieds
293
Limits and Performances
293
Configuration
294
MODBUS Communication
295
Finality
295
Reference Documents
295
Interface
295
Behaviour
296
Data Received from Ieds
297
Data Sent to Ieds
298
Error Management
298
Limits and Performances
299
Configuration
299
DNP 3.0 Communication
300
Finality
300
Interface
300
Behaviour
301
Configuration
303
Finality
303
Interface
303
Behaviour
304
Data Sent to Ieds
306
Limits and Performances
306
Configuration
306
Table of Contents
311
1 Scope of the Document
313
Introduction
313
Definition
313
Commissioning the Product
313
Responsibility
314
Setting Familiarisation
314
2 Requirements
314
3 Commissioning Tests
314
Preparation
314
Check Version & Number
315
Checking the Boards
316
Checking the Binary Signal Inputs
317
Checking the Output Relays
317
Checking the Current-Measuring Inputs
317
Testing the Connection of the Phase Current and Voltage Transformers with Load Current for Correct Phase
318
Testing the Communication
318
Ethernet UCA2
318
Modbus
318
Iec 60870-5-103
318
Iec 60870-5-101
318
Testing the Control Functions
318
Switching from Local to Remote Control
318
Local Control
318
Remote Control
319
Switchgear Unit Not Responding
319
Checking Limit Value Monitoring
320
Completion of Commissioning
320
Table of Contents
323
1 Scope of the Document
325
2 Commissioning Test Record
325
Product Checks
326
Visual Inspection
326
3 Setting Record
326
Table of Contents
331
1 Scope of the Document
333
2 Standard Maintenance Operation
333
Level 1 Diagnosis Facilities
333
Front Panel Fixed Micom C264/C264C LED
333
Front Panel Indications
334
Maintenance Period
336
Maintenance Checks
336
Alarms
336
Opto-Isolators
336
Output Relays
336
Measurement Accuracy
336
Method of Repair
337
Replacing the Complete Micom C264/C264C
337
Replacing a Board
338
Cleaning
348
3 Engineering Maintenance Operation
349
Level 2 Diagnosis Facilities
349
Pacis Equipment Simulator
349
ISAGRAF Workbench Runtime
349
Downloading a NEW Software VERSION
349
Settings for Downloading Software
349
Software Version Verification
350
Copy New Software into Micom C264/C264C
350
Return to Standard Parameters
351
Advertisement
Advertisement
Related Products
Areva MiCOM C264
Areva MiCOM C232
Areva MiCOM P341
Areva MiCOM P225
Areva MiCom P120
Areva MiCom P121
Areva MiCom P122
Areva MiCom P123
areva MiCOM P441
areva MiCOM P442
Areva Categories
Relays
Circuit breakers
Industrial Equipment
Switch
Multiplexer
More Areva Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL