Sign In
Upload
Manuals
Brands
Arcteq Manuals
Protection Device
AQ-M215
Arcteq AQ-M215 Manuals
Manuals and User Guides for Arcteq AQ-M215. We have
1
Arcteq AQ-M215 manual available for free PDF download: Instruction Manual
Arcteq AQ-M215 Instruction Manual (468 pages)
Motor protection IED
Brand:
Arcteq
| Category:
Protection Device
| Size: 29 MB
Table of Contents
Table of Contents
2
Document Inf
7
Document Informa Ormation Tion
7
Version 2 Revision Notes
7
Version 1 Revision Notes
9
Abbr Bbre E Via Viations Tions
11
General
13
IED User Interface Erface
14
Panel Structure
14
Local Panel Structure
14
MIMIC and Main Menu
15
Basic Configuration
15
Navigation in the Main Configuration Menus
15
General Menu
16
Protection Menu
19
Control Menu
25
Communication Menu
40
Measurement Menu
43
Monitoring Menu
46
Configuring User Levels and Their Passwords
49
Functions Unctions
52
Functions Included in AQ-M215
52
Measurements
54
Current Measurement and Scaling
54
Voltage Measurement and Scaling
66
Power and Energy Calculation
77
Frequency Tracking and Scaling
84
Protection Functions
87
General Properties of a Protection Function
87
Non-Directional Overcurrent Protection (I>; 50/51)
96
Non-Directional Earth Fault Protection (I0>; 50N/51N)
103
Directional Overcurrent Protection (Idir>; 67)
107
Directional Earth Fault Protection (I0Dir>; 67N/32N)
115
Negative Sequence Overcurrent/ Phase Current Reversal/ Current Unbalance Protection (I2>; 46/46R/46L)
128
Harmonic Overcurrent Protection (Ih>; 50H/51H/68H)
133
Circuit Breaker Failure Protection (CBFP; 50BF/52BF)
140
Low-Impedance or High-Impedance Restricted Earth Fault/ Cable End Differential Protection (I0D>; 87N)
155
Overvoltage Protection (U>; 59)
164
Undervoltage Protection (U<; 27)
171
Neutral Overvoltage Protection (U0>; 59N)
179
Sequence Voltage Protection (U1/U2>/<; 47/27P/59PN)
185
Overfrequency and Underfrequency Protection (F>/<; 81O/81U)
193
Rate-Of-Change of Frequency (Df/Dt>/<; 81R)
198
Overpower Protection (P>; 32O)
204
Underpower Protection (P<; 32U)
207
Reverse Power Protection (Pr; 32R)
211
Motor Status Monitoring
214
Motor Start/ Locked Rotor Monitoring (Ist>; 48/14)
224
Frequent Start Protection (N>; 66)
235
Non-Directional Undercurrent Protection (I<; 37)
241
Mechanical Jam Protection (IM>; 51M)
245
Power Factor Protection (PF<; 55)
252
Machine Thermal Overload Protection (TM>; 49M)
256
Resistance Temperature Detectors
289
Arc Fault Protection (Iarc>/I0Arc>; 50Arc/50Narc)
294
Programmable Stage (Pgx>/<; 99)
303
Voltage Memory
317
Control Functions
320
Setting Group Selection
320
Object Control and Monitoring
329
Indicator Object Monitoring
339
Milliampere Output Control
340
Programmable Control Switch
342
Analog Input Scaling Curves
343
Logical Outputs
346
Logical Inputs
346
Monitoring Functions
347
Current Transformer Supervision
347
Voltage Transformer Supervision (60)
357
Circuit Breaker Wear
361
Total Harmonic Distortion (THD)
365
Disturbance Recorder (DR)
370
Measurement Recorder
381
Measurement Value Recorder
385
Sy y St Stem Int 6 S Em Integra Egration Tion
390
Communication Protocols
390
Ntp
390
Modbus/Tcp and Modbus/Rtu
391
Modbus I/O
392
Iec 61850
392
Goose
394
Iec 103
394
Dnp3
395
Iec 101/104
397
Spa
399
Analog Fault Registers
399
Real-Time Measurements to Communication
399
Connections and Applica a Tion Examples
402
Connections of AQ-M215
402
Application Example and Its Connections
405
Two-Phase, Three-Wire ARON Input Connection
405
Trip Circuit Supervision (95)
406
Construction and Installa
411
Construction and Installation Tion
411
Construction
411
CPU Module
414
Current Measurement Module
416
Voltage Measurement Module
417
Digital Input Module (Optional)
418
Digital Output Module (Optional)
420
Arc Protection Module (Optional)
421
RTD Input Module (Optional)
422
Serial RS-232 Communication Module (Optional)
423
LC 100 Mbps Ethernet Communication Module (Optional)
425
Double ST 100 Mbps Ethernet Communication Module (Optional)
426
Double RJ-45 10/100 Mbps Ethernet Communication Module (Optional)
428
Milliampere (Ma) I/O Module (Optional)
430
Dimensions and Installation
430
Measurements
433
Current Measurement
433
Hardware
433
Technic Echnical da al Data Ta
433
Power and Energy Measurement
434
Frequency Measurement
435
CPU & Power Supply
435
Auxiliary Voltage
435
CPU Communication Ports
435
CPU Digital Inputs
436
CPU Digital Outputs
437
Option Cards
438
Digital Input Module
438
Digital Output Module
438
Arc Protection Module
439
Milliampere Module (Ma out & Ma In)
440
RTD Input Module
440
Serial Fiber Communication Module
440
Double LC 100 Mbps Ethernet Communication Module
441
Display
441
Functions
441
Protection Functions
441
Non-Directional Overcurrent Protection (I>; 50/51)
441
Non-Directional Earth Fault Protection (I0>; 50N/51N)
442
Directional Overcurrent Protection (Idir>; 67)
443
Directional Earth Fault Protection (I0Dir>; 67N/32N)
444
Negative Sequence Overcurrent/ Phase Current Reversal/ Current Unbalance Protection (I2>; 46/46R/46L)
445
Harmonic Overcurrent Protection (Ih>; 50H/51H/68H)
446
Circuit Breaker Failure Protection (CBFP; 50BF/52BF)
447
Low-Impedance or High-Impedance Restricted Earth Fault/ Cable End Differential Protection (I0D>; 87N)
448
Overvoltage Protection (U>; 59)
448
Undervoltage Protection (U<; 27)
449
Neutral Overvoltage Protection (U0>; 59N)
450
Sequence Voltage Protection (U1/U2>/<; 47/27P/59NP)
450
Overfrequency and Underfrequency Protection (F>/<; 81O/81U)
451
Rate-Of-Change of Frequency Protection (Df/Dt>/<; 81R)
452
Machine Thermal Overload Protection (TM>; 49M)
453
Overpower (P>; 32O), Underpower (P<; 32U) and Reverse Power (Pr; 32R) Protection
454
Power Protection (P, Q, S>/<; 32)
454
Motor Start/ Locked Rotor Monitoring (Ist>; 48/14)
455
Frequent Start Protection (N>; 66)
456
Non-Directional Undercurrent Protection (I<; 37)
456
Mechanical Jam Protection (IM>; 51M)
457
Resistance Temperature Detectors
457
Power Factor Protection (PF<; 55)
458
Arc Fault Protection (Iarc>/I0Arc>; 50Arc/50Narc) (Optional)
458
Voltage Memory
459
Control Functions
460
Setting Group Selection
460
Object Control and Monitoring
460
Monitoring Functions
461
Current Transformer Supervision
461
Voltage Transformer Supervision (60)
461
Circuit Breaker Wear Monitoring
462
Total Harmonic Distortion
462
Disturbance Recorder
463
Tests and Environmental
463
Ordering Inf Dering Informa Ormation Tion
466
Contact and R Ence Informa Ormation Tion
468
Advertisement
Advertisement
Related Products
Arcteq AQ-M210
Arcteq AQ-M255
Arcteq AQ-M257
Arcteq AQ-*2 Series
Arcteq AQ-T216
Arcteq AQ-T256
Arcteq AQ 110F
Arcteq AQ-103
Arcteq AQ-T215
Arcteq AQ-V211
Arcteq Categories
Protection Device
Relays
Accessories
Security Sensors
Industrial Electrical
More Arcteq Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL