Sign In
Upload
Manuals
Brands
Anritsu Manuals
Portable Generator
Rubidium MG36271A
Anritsu Rubidium MG36271A Manuals
Manuals and User Guides for Anritsu Rubidium MG36271A. We have
2
Anritsu Rubidium MG36271A manuals available for free PDF download: Maintenance Manual, Operation Manual
Anritsu Rubidium MG36271A Maintenance Manual (276 pages)
Low-Noise RF/Microwave Signal Generators
Brand:
Anritsu
| Category:
Portable Generator
| Size: 11.7 MB
Table of Contents
Table of Contents
3
Chapter 1 - General Information
11
Scope of Manual
11
Introduction
11
Description
11
Identification Number
11
Additional Documentation
11
Contacting Anritsu
12
Specifications and Options
12
Level of Maintenance
12
Preventive Maintenance
12
Troubleshooting
12
Repair
12
Calibration
12
ESD Requirements
12
Chapter 2 - Functional Description
13
Introduction
13
Mg362X1A Subsystems
13
Digital Control
13
Front Panel Assembly
13
Frequency Synthesis
13
Reference Module
13
Synthesizer Module
14
YIG Assembly
14
Alc/Am/Pulse Modulator
14
RF Deck
14
Power Supply
14
Inputs/Outputs
14
Frequency Synthesis
15
Khz to 2.2 Ghz Digital down Converter
15
RF Outputs 2.2 Ghz to 20 Ghz
15
Frequency Extension Module (FEM)
15
Frequency Switching Speed
16
Step Sweep Mode
16
Modulation
17
Amplitude Modulation
17
Pulse Modulation Operation
17
Pulse Generator Operation
17
Frequency Modulation
18
Phase Modulation
18
ALC Loop Operation
19
External Leveling
19
Power Sweep
19
RF Deck Assemblies
20
RF Deck Configurations
20
YIG-Tuned Oscillator
20
RF Signal Filtering
21
Frequency Extension Module (FEM)
21
Step Attenuators
21
Block Diagram MG36221A
22
Chapter 3 - Performance Verification Using AACS
25
Introduction
25
Test Records
25
Connector and Key Notation
25
Test Equipment List
26
Measurement Uncertainty
30
Maximum Permissible Tolerance of Return Loss of Adapters, Attenuators and Cables
30
Internal Time Base Aging Rate Test
33
Internal Time Base Aging Rate Test with Absolute Time Model 300
33
Internal Time Base Aging Rate Test with Symmetricom (Datum) Model 9390-9600
35
Spurious Signals Tests
36
Harmonic Test Setup
36
Harmonic Test Procedure
38
Non-Harmonic Test Setup
39
Non-Harmonic Test Procedure
39
Single Sideband Phase Noise Test
41
Power Level Accuracy and Flatness Tests
46
Power Level Log Conformity
47
Power Level Accuracy ( -50 Dbm)
48
Power Level Flatness
50
Maximum Leveled Power
52
3-10 FM Verification
54
Test Methodology
54
Equipment Required
54
Max FM Deviation Tests
56
Ext Low Noise FM Max Deviation - Mod Rates up to 1 Mhz
56
Int Low Noise FM Max Deviation - Mod Rates up to 1 Mhz
58
Ext Low Noise FM Max Deviation - Mod Rates > 1 Mhz
59
Int Low Noise FM Max Deviation - Mod Rates > 1 Mhz
61
Ext Wide FM Max Deviation
62
Int Wide FM Max Deviation
63
3-12 Min FM Deviation Tests
64
Ext Low Noise FM Min Deviation (at 1Vpk Input) 5 Ghz Test
64
Int Low Noise FM Min Deviation 5 Ghz Test
64
3-13 FM Flatness Tests
65
FM Highpass Filter 3 Db BW
65
Ext Low Noise FM Flatness and 3 Db BW
65
Int Low Noise FM Flatness and 3 Db BW
68
Ext Wide (Unlocked) FM 3 Db BW
70
3-14 FM Deviation Accuracy Tests
71
Ext Low Noise FM Accuracy
71
Int Low Noise FM Accuracy
73
Ext Wide (Unlocked) FM Accuracy
73
Int Wide (Unlocked) FM Accuracy
75
3-15 FM Harmonic Distortion Tests
75
Ext Low Noise FM THD
75
Int Low Noise FM THD
76
3-16 FM Mode Residual FM and Incidental am Tests
77
Ext Low Noise FM Mode Residual FM / Incidental am
77
3-17 FM Mode Carrier Offset Relative to CW Mode
78
Ext Low Noise FM Mode Carrier Offset
78
Perform Ext FM Offset Calibration to Minimize DC Offsets
78
Int Low Noise FM Mode Carrier Offset
78
Int Low Noise ΦM - Max Phase Deviation
82
Ext Wide ΦM - Max Phase Deviation
83
Modulation Index Calculations
86
3-19 Phase Mod - Min Phase Deviation Tests
88
Ext Low Noise ΦM Min Deviation
88
Int Low Noise ΦM Min Deviation
89
3-20 Phase Mod - Flatness Tests
89
Ext Low Noise ΦM Flatness and 3 Db BW
89
Measurement Uncertainties and Test Limits
90
Int Low Noise ΦM Flatness and 3 Db BW
92
Measurement Uncertainties and Test Limits
92
Ext Wide ΦM 3 Db BW
95
Measurement Uncertainties and Test Limits
95
Int Wide ΦM 3 Db BW
96
3-21 Phase Mod - Deviation Accuracy Tests
99
Ext Low Noise ΦM - Phase Deviation Accuracy
99
Int Low Noise ΦM - Phase Deviation Accuracy
100
Ext Wide ΦM - Phase Deviation Accuracy
100
Int Wide ΦM - Phase Deviation Accuracy
101
3-22 Rear Panel FM-Out Tests
102
FM-Out Accuracy, Ext FM
102
FM Out" Flatness, Ext FM
103
3-23 Amplitude Modulation Tests
104
Equipment Required
104
AM Meter Verification
105
AM Depth Indicator Settings
106
AM Internal Source Verification (Linear Mode)
106
AM SEN_DAC Settings (Internal Source)
107
AM External Mod Linear Verification (Linear Mode)
107
AM SEN_DAC Setting (External Source Linear Mode)
108
AM External Mod LOG Verification (Linear Mode)
108
3-24 Pulse Modulation Tests with the 86100C Oscilloscope
109
Pulse Rise Time, Fall Time and Overshoot Measurement
110
Pulse Power Accuracy Measurement
112
Pulse On/Off Ratio
114
Chapter 4 - Adjustment
117
Introduction
117
Test Equipment List
117
Maximum Permissible Tolerance of Return Loss
119
Station Asset Utility
123
Station Asset Utility Setup
123
Enter Test Equipment Assets
124
Set the Communication Parameters
125
AACS Testing
126
Initial Calibration
127
Equipment Required
127
Harmonics and Spurious Signals Test
128
Equipment Required
128
Single Sideband Phase Noise Test
131
Equipment Required
131
Power Level Accuracy and Flatness
133
Equipment Required
133
Pulse Modulation Tests
135
Equipment Required
135
External Pulse Reference Cal
135
External Pulse Reference Calibration
136
External Pulse
136
Internal Pulse
136
External Video Feedthru
137
Internal Video Feedthru
137
Amplitude Modulation Tests
138
Equipment Required
138
AM Meter Calibration
139
AM Internal Source Calibration
140
Am_Cal_Dac Linear Calibration
141
Am_Cal_Dac LOG Calibration
142
AM External Mod Linear Calibration
143
AM External Mod LOG Calibration
144
AM SEN_DAC Setting (External Source LOG Mode)
145
ALC Gain Calibration
145
4-10 FM and Phase Modulation Calibration
146
Ext FM ADC Offset
148
Ext FM Input Gain
149
Rear Panel FM Waveform Amplitude
149
LNFM Tune Gain and FM Delay for YIG Low Band
150
LNFM Tune Gain for YIG High Band
151
Wide FM Tune Gain for YIG Low Band
152
Wide FM Tune Gain for YIG High Band
153
Chapter 5 - Troubleshooting
155
Introduction
155
Error Messages
155
Self Test Error Messages
155
Mg362X1A Block Diagram
156
Main Board Designator Pin-Outs
157
Basic Configuration
166
Troubleshooting
167
Malfunctions Not Displaying an Error Message
167
Self Test Messages
169
System Messages that Display Fail
169
SG Messages
169
MOD Supply Voltage Errors
169
ALC Temperature Error
169
YIG Temperature Error
170
SWF Errors (Switched Filter Errors)
170
REG Errors (Regulator Errors)
170
The OCXO Module Is Not Phase-Locked to the External 10 Mhz Reference
170
The Hi-Performance Reference Not Phase-Locked to the External 100 Mhz Reference
171
The Mg362X1A Displays Lock Error
171
ALC Error
172
Output Power Level Related Problems in the DDC (9 Khz to 2.2 Ghz)
172
Output Power Level Related Problem above 20 Ghz
173
AM Meter or Associated Circuitry Failed
173
Internal FM or Φ Modulation Circuitry Failed
173
Pulse Circuitry Failed
174
Chapter 6 - Removal and Replacement
175
Introduction
175
Replaceable Parts
175
Adjustment and Verification after Replacing an Assembly
180
Semi-Rigid Cable Installation (Standard Model)
183
SMA Cable Installation (Standard Model)
184
Frequency Extension Module (FEM) Cable Installation
185
Option 13 Configuration
186
Option 3 and Option 56 Configuration
187
Option 23 Configuration
188
6-10 Removal Procedures
189
Remove the Handles
189
Remove the Rear Feet
190
Remove the Covers
191
Remove the Top Sub-Panel
192
Remove Front Panel
192
Remove the Rear Panel
194
Remove the Rear Panel BNC PCB
196
Remove the Power Supply
197
Remove the Sub-Panel
198
Remove the Standard Reference Module
199
Remove the Modules with Mounting Flange
201
Remove the YIG Module
203
Procedure
203
Remove the Frequency Extension Module (FEM)
204
Procedure
205
Remove the Modules with Mounting Bracket
205
Procedure
206
Remove the Dielectric Resonator Oscillator (DRO) (Option 13)
207
Remove the Main Board
209
Introduction
211
Uncertainty Specifications
211
Adapter, Attenuator and Cable Insertion Loss
211
Test Records
211
A-5 Technical Reference
212
Internal Time Base Aging Rate Test (Optional
212
Harmonics and Harmonically Related Signal Test Records
213
Non-Harmonic Testing (Part 1
218
Non-Harmonic Testing (Part 2
219
Single Sideband Phase Noise Test (Standard
222
SSB Phase Noise (Option
224
Power Line & Fan
227
Power Level Log Conformity
229
Power Level Accuracy Test
231
Power Level Accuracy Test
233
Power Level Accuracy Test
234
Power Level Accuracy Test
235
Power Level Accuracy Test
236
Power Level Accuracy Test
237
Power Level Accuracy Test
238
Power Level Flatness Test (no Option 2
239
Power Level Flatness Test (Option 2
241
Maximum Leveled Power Test (Without Option 15
243
Maximum Leveled Power Test (with Option 15
245
Maximum Leveled Power Test (Without Option 15
246
Frequency Modulation Tests (Option 12
247
Frequency Modulation Tests (Option 12
249
Frequency Modulation Tests (Option 12
250
Frequency Modulation Tests (Option 12
251
Frequency Modulation Test (Option 12
252
Amplitude Modulation Test (Option 12
253
Pulse Modulation Tests (Option 12
256
Pulse Modulation Tests (Option 12
258
Pulse Modulation Tests (Option 12
259
Pulse Modulation Tests (Option 12
260
Pulse Modulation Tests (Option 12
261
Appendix B - Instrument Messages
263
B-3 Informational Messages
265
B-4 Warning Messages
267
B-5 Self Test Messages
268
Appendix C - Updating Firmware
271
Introduction
271
C-2 Updating Firmware on the Mg362X1A
272
Use a USB Memory Device
273
Advertisement
Anritsu Rubidium MG36271A Operation Manual (164 pages)
Low-Noise RF/Microwave Signal Generators, 9 kHz to 20.0/43.5/70.0 GHz
Brand:
Anritsu
| Category:
Portable Generator
| Size: 15.36 MB
Table of Contents
Table of Contents
3
Chapter 1 - General Information
9
About this Guide
9
Additional Documentation
9
Description
10
Instrument Integrity
10
Antivirus Protection
10
ESD Caution
11
Instrument Care and Preventive Maintenance
11
Cleaning the Fan Grill
11
Connector Care
11
Power Output
11
Unpacking the Product
11
Operating Environment
11
1-10 Typographic Conventions
12
Preparation for Storage/Shipment
12
Preparation for Storage
12
Preparation for Shipment
12
1-12 Contacting Anritsu for Sales and Service
12
Instrument Identification
12
Chapter 2 - Instrument Overview
13
Introduction
13
Front Panel
13
Front Panel Controls
14
Menu Buttons
14
Rotary Knob
14
Cursor Control Pad
14
Numeric Keypad
15
RF Output
15
Rear Panel
16
Rear Panel Bncs
17
Installation and Power Requirements
19
Powering on the Mg362X1A
19
Standby Mode
20
Warm-Up Time
20
Common GUI Controls
21
GUI Overview
22
Title Bar
23
Menu Buttons
24
2-10 Status Area
25
Entering Data
26
Opening a Parameter
27
Cursor Control Buttons
27
Text Entry
30
System Menu
32
System Information
33
INSTRUMENT Menu
33
SOFTWARE Menu
34
CONNECTIVITY Menu
35
2-13 SETTINGS Menu
36
DISPLAY Settings
37
SOUND Settings
37
ETHERNET Settings
38
Network Settings
39
2-14 Connecting to the Mg362X1A or Localhost
41
Working with the Localhost
41
Measurement Setup Parameters
41
2-15 REMOTE Settings
41
GPIB Interface Connection and Setup
41
SCREENSHOT Settings
43
Previewing Screenshots
44
DATE TIME Settings
45
OPTIONS Settings
46
RESET Menu
47
Resetting to Default Parameters
48
2-16 FILES Menu
49
File Management
49
File Locations
49
File Management Operations
49
2-17 DIAGNOSTICS Menu
50
EVENT LOG Menu
50
Self Test
51
SERVICE Mode
53
Tools
54
Chapter 3 - Instrument Operation
55
Introduction
55
Power-On Display
55
Standby Mode
55
Self Testing the Mg362X1A
56
Resetting to Default Parameters
56
CW Frequency Operation
57
FREQUENCY Menu
57
FREQUENCY Menu
58
FREQUENCY Menu (Option 36)
59
FREQUENCY PRESETS Menu
60
Frequency Step Sweep Operation
61
SWEEP Menu
61
SUMMARY Menu
62
Step Sweep SETUP Menu
63
Editing the Current Start/Stop Frequencies
63
Setting the Step Size
64
Number of Points
64
Setting DWELL TIME
64
Setting SWEEP DIRECTION
65
Setting PRESET SWEEP RANGES
65
RANGE Menu
66
Setting SWEEP TYPE
66
Starting a Step Sweep
67
TRIGGER Menu
67
Sweep TRIGGER TYPES
68
Initiate Step Sweep
69
LIST Menu
70
SWEEP LIST Index
70
LIST TRIGGER Menu
72
LIST - LIST Menu
73
Copy to the LIST
74
3-10 Power Level Operations
75
LEVEL Menu
75
LEVEL SETUP Menu
77
Units
79
LEVEL PRESETS Menu
80
Setting Fixed Power
81
Setting a Preset Power Level
83
LEVEL OFFSET Menu
84
Edit the Offset Value
85
Power Level Sweep Operation
86
LEVEL SWEEP Menu
86
Setting CW Power Sweep, Step Size, and Dwell Time
87
Triggering a CW Power Sweep
87
RANGE Menu
90
Setting a Power Level Sweep Range
90
Setting SWEEP TYPE
91
3-12 Setting the ALC Control
92
ALC Menu
92
ALC Level Modes
92
Step Attenuator (Option 2)
94
ATTENUATOR Menu
94
Decoupling the Attenuator
95
POWER SEARCH Menu
97
3-14 Modulation
98
3-15 Amplitude Modulation
98
Setting am SOURCE
98
Amplitude Modulation Set to Internal
99
Amplitude Modulation Set to External
102
3-16 Frequency Modulation
104
Setting FM SOURCE
104
Frequency Modulation Set to Internal
105
Frequency Modulation Set to External
108
3-17 Phase Modulation
110
PHASE Modulation Set to Internal
110
PHASE Modulation Set to External
113
3-18 Pulse Modulation
114
Setting Pulse SOURCE
114
PULSE Modulation Set to Internal
115
Setting Period and (PRF) FREQUENCY
116
Pulse Width-Delay Menu
116
PULSE Modulation Set to External
120
3-19 Saving/Recalling Instrument Setups
121
Saving Setups
121
Erasing Stored Setups
122
3-20 Reference CALIBRATION
123
100 Mhz Calibration (Standard Reference)
124
10 Mhz Calibration (Option 3)
124
100 Mhz Calibration
125
10 Mhz Calibration with Option 66
127
RUBIDIUM Menu (Option 56)
128
GNSS Menu (Option 66)
129
3-21 Reference Status Conditions
130
Reference Oscillator Current Source
130
Reference Oscillator Lock Status
130
Reference Oscillator 100 Mhz Lock Status
131
Reference Oscillator GPS Lock Status
131
Reference Oscillator Rubidium Lock Status
131
Config Menu
132
INCREMENT Menu
133
Increment Size
133
RESET Menu
134
Chapter 4 - Operation Verification
135
Introduction
135
Test Records
135
Initial Mg362X1A Checkout
135
Power on
135
Warm-Up Time
135
Self Test
135
Presetting the Mg362X1A
136
Frequency Synthesis Test
137
Level Accuracy and Flatness Test
139
Accuracy Test Procedure
140
Flatness Test Procedure
142
Appendix A - Software Installation
145
PC Requirements
145
Installation
145
FILE (File Management
146
Appendix B - Updating Firmware
147
Introduction
147
B-2 Updating Firmware on the Mg362X1A
148
Use a USB Memory Device
149
Appendix C - Software Option Upgrades
151
Exporting a Software Configuration File
151
Importing Software License
151
Appendix D - Software Installation
153
PC Requirements
153
Installation
153
FILE (File Management
154
Appendix E - Instrument Messages
155
Error Messages
155
Informational Messages
157
Warning Messages
159
Self-Test Messages
160
Advertisement
Related Products
Anritsu MG3690B
Anritsu MG369 C Series
Anritsu MG3690C
Anritsu MG3691B
Anritsu MG3694B
Anritsu MG3695B
Anritsu MG3691C
Anritsu MG3692C
Anritsu MG3693C
Anritsu MG3694C
Anritsu Categories
Measuring Instruments
Test Equipment
Portable Generator
Control Unit
Thermometer
More Anritsu Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL