Aerco 5R5-384 Boiler Management System Manuals
Manuals and User Guides for Aerco 5R5-384 Boiler Management System. We have
1
Aerco 5R5-384 Boiler Management System manual available for free PDF download: User Manual
Aerco 5R5-384 User Manual (139 pages)
For Control of Up to Thirty-two (32) AERCO Boilers, including: Benchmark Series, Modulex MLX Series, Modulex EXT Series, KC-1000
Brand:
Aerco
| Category:
Control Systems
| Size: 4 MB
Table of Contents
Table of Contents
2
Foreward
9
Chapter 1: Acs General Information
11
Safety Precautions and Warnings
11
Introduction
11
General Description
11
Features
12
Simplified Installation and Set-Up
12
Control System Interface
12
Retention of Menu Option Settings
13
Configuration Options
13
Sequential and Parallel Operation
13
Accuracy
13
Sequential Operation
13
Fault Alarm Surveillance
13
ACS Programming Via RS232 Port
13
Chapter 2: Acs Installation
15
Introduction
15
Site Selection and Mounting
15
Mounting the ACS
15
Site Selection and Mounting
16
Power Wiring
17
Sensor Installation and Wiring
18
Header Sensor Installation
19
Return Sensor Installation
19
Outdoor Air Sensor Installation
20
Rs485 (Modbus) Wiring at the Acs
22
ACS Bias Switches & Loop Termination Resistors
22
Aerco Rs485 (Modbus) Wiring, Bias, and Termination
23
RS485 Wiring, Bias, & Termination (BMK & KC1000 Boilers)
23
RS485 Wiring for Modulex Series Boilers
29
Sample Rs485 (Modbus) Network Diagrams
30
Rs485 Wiring at the Acs
31
Relay Wiring
32
System Start Relay
33
Fault Alarm Relay
33
Auxiliary Relay
33
Interlock Wiring
32
Interlock 1 (INT 1) Wiring
32
Interlock 2 (INT 2) Wiring
32
Setback Wiring
32
Ma Wiring
33
Mounting & Wiring the Optional Acs Relay Box
33
Relay Panel Installation and Wiring
34
Relay Panel Components
39
Power
39
Inputs
39
Outputs
39
Relay Panel Operation
40
Acs Programming for Use with the Acs Relay Panel
41
RS485 Menu Settings for Relay Panel Programming
41
Configuration Menu - Relay Panel Settings
41
Chapter 3: Operation
43
Introduction
43
Front Panel Operating Controls and Displays
43
Menu Processing Procedure
45
Operating Menu
47
Header Temp and Percent of Load
47
Header Setpoint
47
Outside Air Temp
48
I/O Status
48
Return Temp
48
Network Boiler Outlet Temperature
48
Network Boiler Error Code
48
Setup Menu
49
Enter Password
49
Date and Time Menu Options
49
Rs232 Menu
49
Rs232 Mode
49
Rs232 Baud Rate
49
Modbus Address
50
Network Timeout
50
Modbus Pass Thru
50
Rs485 (Modbus) Menu
50
Rs485 Baud Rate
50
Min Slave Addr
50
Max Slave Addr
50
Number Netwk Blrs
50
Modbus Cntl Type
51
NETW BOILER XX Address=Yyy
51
Field Adjust Menu
51
Header Set Mode
51
Hdr High Limit
51
Hdr Low Limit
51
Internal Setpt
51
Reset Ratio
52
Bldg Ref Temp
52
Remote Signal
52
Offset Enable
52
Offset Menu Options
52
Setting up an Offset Schedule
52
Setting up a Manual Offset Schedule
53
Configuration Menu
53
Blr Cntl Select
53
Boiler Op Mode
53
Parallel Mode
54
Sequential
54
Sys Intlk Config
54
Blr Start Level
54
Blr Stop Level
54
Max Power Input
55
Fail Safe Mode
55
LEAD BLR SELECT (Lead Boiler Selection)
55
LAST BLR SELECT (Last Boiler Selection)
55
Rotate Time
55
RET SENSOR MODE (Return Sensor Mode)
55
PLANT DT LIMIT (Plant Delta-Temperature Limit)
55
Boiler Delay
56
DHW OPTION (Domestic Hot Water Option)
56
NUMBER DHW BLRS (Number of Domestic Hot Water Boilers)
56
DHW SIGNAL (Domestic Hot Water Signal)
57
NUM DHW PRIORITY (Number of DHW Priority Boilers)
57
Valve Wait States
57
SYS RELAY OPTION (System Relay Option)
57
Boost Temp
57
Ret Temp Bst Dis (Return Temperature Boost Disable)
57
Boost Max Timer
58
Tuning Menu
58
Proportional Bnd
58
Integral Gain
59
Derivative Gain
59
Decreasing Boiler Cycles
59
HI_DB_SETPT_EN (High Deadband Setpoint Enable)
59
Deadband High
59
Deadband Low
59
SETPT down RATE (Setpoint down (Descending) Rate
60
Demand Offset
60
Relay Menu
60
Sys Start Temp
60
Sys Start Option
60
Sys Start Intlk
60
Aux Relay Open
61
Aux Relay Close
61
Fault Alrm Relay
61
Fault Alarm Blrs
61
Fault Alrm Clear
61
Calibration Menu
61
Hdr Sens Offset
61
Outd Sens Offset
61
Ma Offset
62
Retn Sens Offset
62
Ramp up % / Min
62
Ramp down % / Min
62
Reset Defaults
62
Passthru Write
63
Valve Wait Time
63
SYSTEM OVERRIDE (Modbus Enable/Disable)
63
Acs Quick-Start Guide Menu
63
CONSTANT SETPT MODE (Default)
64
Remote Setpt Mode
65
Outdoor Reset Mode
66
Chapter 4: Programming Acs Operating Modes
67
Introduction
67
Outdoor Reset Mode
67
Selecting Outdoor Reset Mode
68
Determining Reset Schedule
68
Entering Reset Ratio and Building Reference Temperature
69
Selecting Boiler Operating Mode
69
Entering System Start Temperature
70
Entering Boiler Start and Boiler Stop Levels
70
Remote Setpoint Mode
71
Selecting Remote Setpoint Mode
71
Entering Header High Limit and Low Limit Temperatures
72
Selecting Remote Signal Type
73
Selecting Boiler Operating Mode
73
Entering Boiler Start & Stop Levels
74
Constant Setpoint Mode
74
Selecting Constant Setpoint Mode
75
Selecting Internal Setpoint Temperature
75
Selecting Boiler Operating Mode
76
Entering Boiler Start and Boiler Stop Levels
76
Temp and Load" Option
77
Start Enabled" Option
77
System Initialization and Polling
77
Testing the System Using the C-More Controls
78
Chapter 5: Troubleshooting
81
Fault Messages and Common Problems
81
Appendix A: Acs Menus
85
Appendix B: Status and Fault Messages
91
Acs Status and Fault Messages
91
C-More Status and Fault Messages
92
Conversion Equations for Temperature Variables
96
Interpreting Bcm Fault Codes (Modulex)
97
Bcm (Boiler Communication Module) Fault Codes
98
Bmm (Burner Management Module) Fault Codes
99
Acs (Aerco Control System) I/O Status
102
Appendix C: Reset Schedule and Outdoor Reset Ratio Charts
105
Using the Charts to Determine Reset Schedule
105
Determining Reset Schedule by Formula
105
Appendix D: Ntc Temperature Sensor Resistance
110
Appendix E: Acs Wiring Diagram
111
Appendix F: Acs Parts and Accessories
112
Appendix G: Programming Using Rs232 Communication
113
Introduction
113
AQUIRING the Putty APPLICATION
113
Logging on to a Remote Machine Using Putty
113
Running a Command on a Remote Machine Using Putty
114
Rs232 Communication Set-Up
115
Programming Procedure
115
Appendix H: Acs Modbus Address Assignments
121
Acs Controller Standard Input Register Assignments
121
Acs Controller Standard Holding Register Assignments
128
Appendix I: Start and Stop Levels
137
11/22/2017 AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913