Sign In
Upload
Manuals
Brands
ActronAir Manuals
Air Handlers
ULTRASLIM 2 LRE-170CS
ActronAir ULTRASLIM 2 LRE-170CS Manuals
Manuals and User Guides for ActronAir ULTRASLIM 2 LRE-170CS. We have
1
ActronAir ULTRASLIM 2 LRE-170CS manual available for free PDF download: Troubleshooting Manual
ActronAir ULTRASLIM 2 LRE-170CS Troubleshooting Manual (50 pages)
Split Unit
Brand:
ActronAir
| Category:
Air Handlers
| Size: 19 MB
Table of Contents
Table of Contents
2
Safety Caution
3
General Troubleshooting
4
Error Display (Indoor Unit)
4
Error Display (for some Outdoor Units)
5
Information Inquiry
6
Outdoor Unit Point Check Function
9
Error Diagnosis and Troubleshooting Without Error Code
11
Remote Maintenance
11
Field Maintenance
12
Quick Maintenance by Error Code
17
Troubleshooting by Error Code
18
EH 00/ EH 0A / EC 51/F4 (EEPROM Parameter Error Diagnosis and Solution)
18
EL 01/E1 (Indoor and Outdoor Unit Communication Error Diagnosis and Solution)
19
Eh 03 / Ec 07 / F5 / Ec 71
22
Eh 60 / Eh 61 / Ec 53 / Ec 52 / Ec 54 / Ec 56 / Ec 50 / F1 / F2 / F3 / P7
26
EL 0C (Refrigerant Leakage Detection Diagnosis and Solution)
27
EH 0E(Water-Level Alarm Malfunction Diagnosis and Solution)
28
Pc 00 /P0 / Pc 04 /P4
29
Pc 01 / P1 / Pc10 / Pc11 / Pc12
30
PC 03 / PC 31 / J6 (Low Pressure Protection Diagnosis and Solution)
31
Pc 02 / P2
32
EC 0D (Outdoor Unit Malfunction Diagnosis and Solution)
33
Pc 40 / J4
33
Pc 08 / F0 / Pc 46 / Pc 49
34
PC 0F / J3(PFC Module Protection Diagnosis and Solution)
36
EC 72 (Lack Phase Failure of Outdoor DC Fan Motor Diagnosis and Solution)
37
PC 43 (Outdoor Compressor Lack Phase Protection Diagnosis and Solution)
38
PC 45 (Outdoor Unit IR Chip Drive Failure Diagnosis and Solution)
39
PC 0L/LP (Low Ambient Temperature Protection)
39
PC 30/J5 (High Pressure Protection Diagnosis and Solution)
39
PC 0A/J1 (High Temperature Protection of Condenser Diagnosis and Solution)
41
PC 06/J2 (Discharge Temperature Protection of Compressor Diagnosis and Solution)
42
J0 (High Temperature Protection of Evaporator Diagnosis and Solution)
43
J8 (AC Power Input Voltage Protection Diagnosis and Solution)
44
EH 0B(Communication Error between Indoor Two Chips Diagnosis and Solution)
45
EH Ba / EH 3A / EH 3B
46
Check Procedures
47
Temperature Sensor Check
47
Compressor Check
47
IPM Continuity Check
49
Advertisement
Advertisement
Related Products
ActronAir ULTRASLIM 2 LRE-071CS
ActronAir ULTRASLIM 2 LRE-100CS
ActronAir ULTRASLIM 2 LRE-125CS
ActronAir ULTRASLIM 2 LRE-140CS
ActronAir ULTRASLIM 2 LRC-071CS
ActronAir ULTRASLIM 2 LRC-100CS
ActronAir ULTRASLIM 2 LRC-170CS
ActronAir Cascade 2 CRC-100CS
ActronAir Cascade 2 URC-125CS
ActronAir Cascade 2 URC-140CS
ActronAir Categories
Air Conditioner
Air Handlers
Controller
Air Conditioner Accessories
Remote Control
More ActronAir Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL