Sign In
Upload
Manuals
Brands
ABLE Manuals
Measuring Instruments
RHEONIK RHM NT Series
ABLE RHEONIK RHM NT Series Manuals
Manuals and User Guides for ABLE RHEONIK RHM NT Series. We have
1
ABLE RHEONIK RHM NT Series manual available for free PDF download: Installation & Maintenance Instructions Manual
ABLE RHEONIK RHM NT Series Installation & Maintenance Instructions Manual (57 pages)
Coriolis Flowmeter
Brand:
ABLE
| Category:
Measuring Instruments
| Size: 1.47 MB
Table of Contents
Table of Contents
2
Important Safety Instructions for Operating Coriolis Flowmeters
4
Manufacturer's Liability
5
Typical Applications and Benefits
6
Installation Instructions (in Brief)
7
1 General Description of System
8
The Flow Measurement System
8
Dimensions of Transmitter Casing RHE12
9
Dimensions of Sensor RHM
9
Installing Transmitter RHE12
9
2 Assembly and Installation
11
Installation Instructions for Measuring Sensor RHM
11
Heating / Filling of a Sensor (Flowmeter)
14
3 Electrical Connection of RHM
15
Cable Specifications
15
Wiring between the Measuring Sensor and the RHE12
15
4 Installation of the RHE
17
Connecting the Power Supply
17
5 Operation and Programming
18
Basic Operation and Settings Principle
18
Startup Display
19
Measurement Display
19
User Setup
20
Resetting the Mass Totalizer
20
Zeroing
20
Measurement Value Damping
20
Rate and Quantity Unit Display
21
Low-Flow Cut-Off
21
Allocation of Analog Output Function
21
Span Analog Output
21
Basic Settings
22
Scaling-M
22
Scaling-D
22
Device Hi-Limit Range
22
Temperature Compensation
23
Diagnostics Display Primary Sensor Signals
23
Diagnostics-Measuring Frequency
23
Diagnostics-Analog Output
23
Diagnostics-Pulse Output
24
Sensor Diagnosis
24
Display Run-Time Counter
24
6 Zeroing Procedure
25
7 Error Diagnostics
26
8 Adjusting the RHE12 Transmitter
27
Setting the Frequency Divider, Pulse Output and Measuring Frequency
27
9 Troubleshooting
29
Error Status of Output
29
Pulse Output
29
Current Output
29
Notes on Troubleshooting
29
No Display Available on the Device
29
Error Display "Pickup Error
30
Notes on Troubleshooting
31
10 Technical Data-Transmitter
32
11 Transmitter Spare Parts
33
12 Technical Data-Measuring Sensor
33
Advertisement
Advertisement
Related Products
ABLE RHEONIK ET Series
ABLE RHEONIK RHE 15
ABLE RHEONIK RHE 12
ABLE RHEONIK HT
ABLE BEKA associates BA648CF-F
ABLE BEKA associates BA648CF-P
ABLE BEKA BA504E
ABLE BEKA BA524E
ABLE Computrac Vapor Pro Rx
ABLE CT-3500
ABLE Categories
Printer
Measuring Instruments
Switch
Accessories
Air Cleaner
More ABLE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL