Over scanning:

Enter factory mode, enter
"OVERSCAN" submenu, you can adjust the over scan in these menu.

OutFactory reset:

Enter factory mode, enter
FACTORY SET" item and press OK button to reset the flash memory.
TV set will restart when it is finish.
INIT EEPROM:
Enter factory mode, enter
RESET DEFAULT" item and press OK button to reset the EEPROM.
TV set will restart when it is finish.

Update software (by USB):

Copy the new software (name by "MERGE.bin") to the root directory
of USB drive. Plug the drive to the
socket, make sure you use the socket 2). Enter factory, select "Software
Update (USB)" item and press OK button to begin update. TV set will
restart when finish. Note, you need to restart the TV set again by AC
power.