  • Page 1 VT-HMI 5071 User’s Manual Vantron Technology www.vantrontech.com All Rights Reserved...
  • Page 2 VT-HM I-5071 Revision History: Version Description Date V1.0 First release Apr. 25, 2008 V1.1 Update Ordering Information Sept. 17, 2008 V1.2 Add VESA Information Jan. 25, 2010...
  • Page 3: Table Of Contents

    Table of Contents Foreword......................1 Copyright Notice ................1 Notes ....................2 Statement ...................2 Disclaimer...................3 Limitation of Liability/Non-warranty ..........3 Safety Instructions ................3 Precautions ..................4 Safety Instructions for Power Cables and Accessories ....5 Overview......................7 Introduction ..................7 Product Series..................8 2.2.1 Product Order Coding Rule ..........8 2.2.2 Ordering Information ............9 VT-HMI-5071 Hardware Instructions ............
  • Page 4 3.6.2 Ethernet Interface ............18 3.6.3 D Sub-9 RS232 Connector ..........19 3.6.4 USB Host Connector ............20 3.6.5 CAN Connector ............... 20 I/O Interface Instructions ............. 21 3.7.1 RS485/422............... 21 Packing List ..................23 Software Instructions................24 Brief Introduction................24 4.1.1 Serial Port Instructions ..........
  • Page 5: Foreword

    Vantron r eserves all rights of this manual, including the right to change the content, form, product featur es, and specifications contained her ein at any time without pri or notice.
  • Page 6: Notes

    No part of this manual may be copied, reproduced, translated or sold. No changes or other purposes are per mitted without the prior written consent of Vantron. Vantron res erves the right of all publicly-released copies of this manual. Notes...
  • Page 7: Disclaimer

    Limitation of Liabilit y/Non-w arranty For direct or indirect damage to this device or other devices of Vantron caused by failure of conforming to this manual or the safety instructions on device label, Vantron assumes neither warranty nor legal liability even if the device is still under warranty.
  • Page 8: Precautions

    VT-HM I-5071 Precautions  Pay attention to the product labels/safety instructions printed on silk screens.  Do not try repairing this product unless declared in this manual.  Keep away from heat source, such as heater , heat dissipater, or engine casing.
  • Page 9: Safety Instructions For Power Cables And Accessories

    Start only with power source that satisfies voltage label and the voltage necessary according to this manual. Please contact technical support personnel of Vantron for any unc ertainty about the requirements of nec essary power source. Use tested power sourc e...
  • Page 10 Do not try cleaning exposed elec tronic components unless with a dust collector.  Support for special fault: Power off and contact technical support personnel of Vantron in case of the following faults:  The device is damaged.  The temperatur e is excessively high.
  • Page 11: Overview

    VT-HM I-5071 Overview Introduction Thank you for choosing Vantron. It is our commitment to provide our valued customers with the embedded devices equipped with the state-of-the-art technology and the best produc t services. HMI, the abbreviation for Human-Machine Interfac e, enables the...
  • Page 12: Product Series

    VT-HM I-5071 Product Serie s 2.2.1 Product Order Coding Rule VT-HMI- A BB C: Type suffix: 1: Basic type; 2: Enhanced type or other types Screen size: 07、 08、 10、 15: for LCD in 7、 8、 10、 15 inches. Product series: 3:PXA270 ARM10 proc essor platform 5:IMX31 ARM11 processor platform 6:Intel ATOM x86 processor platform...
  • Page 13: Ordering Information

    VT-HM I-5071 2.2.2 Ordering Information Series 3: PXA 270 ARM10 proc essor based 8.4” TFT, PXA270 520MHz, Ethernet, RS232, VT-HMI-3081 RS422/485, USBH, USBD 8.4” TFT, PXA270 520 MHz, Ethernet, 5xRS232, VT-HMI-3082 2xRS422, RS485, 4x USBH, CAN 10.4” TFT, PXA270 520MHz, Ethernet, RS232, VT-HMI-3101 RS422/485, USBH, USBD 10.4”...
  • Page 14: Vt-Hmi-5071 Hardware Instructions

    VT-HM I-5071 VT-HMI-5071 Hardware Instructions Product Appearance Front & Side View Top View Back & Side View...
  • Page 15: Specifications

    VT-HM I-5071 Specifications Processor FreeScale iMX31,ARM11, 532MHz 128 MB(up 256 MB), On Board RAM 266MHz Memory On Board RO M 32MB Nor Flash External 1x MMC/SD, USB 2.0 Storage Storage 7”,TTL TFT, 16:9 , 800 x 480, Resolution 16bit Color Contrast 500:1 Brightness...
  • Page 16 VT-HM I-5071 Dimensions 230x168 x47mm Install Window 208x146 mm VESA Install 75x75mm, 3 mm Screw Mechanical Weight 1.2Kg Aluminum Alloy with Black Color Enclosure (optional for other colors) Operating:-10 ℃ ~ +60℃ ( ETR:-30 ℃ ~ +70℃ O ptional) Temperatur e Storage: -20 ℃...
  • Page 17: Interface Instructions

    VT-HM I-5071 Interface Instructions 3.3.1 Bottom View D Sub-9 RS232 Serial Port RS 485/422 Serial Port USB Host Audio 12/24V Power Input Client...
  • Page 18: Left View

    VT-HM I-5071 3.3.2 Left View CAN WiringOut Hole SD/M M C, M ounting/Locating Holes Internal...
  • Page 19: Dimension

    VT-HM I-5071 Dimension Mounting Window Size: 208x146 mm...
  • Page 20: Hardware Installation

    VT-HM I-5071 Hardw are Inst allation The produc t suppor ts standard VESA mounting (75 x 75 mm x Φ 3 mm) as well as side mounting. The left and right sides of the device housing have two mounting slots respectively for inserting mounting brackets to needed positions by tightening screws ( as shown below): Waterproof Cushion M ounting...
  • Page 21: Interface Description

    VT-HM I-5071 Interface Description 3.6.1 DC24V Power Input 3 pins 5.08mm pitch terminal with screw lock Description GND(power ground) Power (+24V DC +) Protec tion Ground...
  • Page 22: Ethernet Interface

    VT-HM I-5071 3.6.2 Ethernet Interface Standard RJ45 interface, supporting 10 M/100M self-adaptation Description N.C. N.C. N.C. N.C.
  • Page 23: D Sub-9 Rs232 Connector

    VT-HM I-5071 3.6.3 D Sub-9 RS232 Connector Standard ver tical DB-9 male connector, baud rate up to 921 , 600bps Description GND (ground pin)
  • Page 24: Usb Host Connector

    VT-HM I-5071 3.6.4 USB Host Connector Standard USB host connector , type A Description USB VCC USB NEG USB POS 3.6.5 CAN Connector 2 Pins 3.81mm pitch terminal Description CANH CANL...
  • Page 25: I/O Interface Instructions

    VT-HM I-5071 I/O Interface Instructions 3.7.1 RS485/422 3.7.1.1 485 Cable Connection 3.7.1.2 422 Cable Connection 3.7.1.3 RS422/485 RS422 and RS485 share the same RJ11 interfac e, and the electrical...
  • Page 26 VT-HM I-5071 proper ties ther eof are determined according to differ ent connection modes.  RS 422 wiring suggestion  RS 485 wiring suggestion...
  • Page 27: Packing List

    VT-HM I-5071 Packing L ist Pa rt Des cri ption Quanti ty Type Install Mechanical tools 1pcs 140040-0017EV,VANTRON Cushion for Enclosure's Front 140010-0036EV,VANTRON Panel Protection Screw, Mounting Enclosure 4pcs 250010-01001EV,VANTRO Power Terminal 210071-01041EV, (3pins) ANYTEC:VM-5.08-3P CAN Bus Terminal (Optional) 210060-0103BEV, (3pins) ANYTEK:VM-3.81-3P...
  • Page 28: Software Instructions

    VT-HM I-5071 Software Instructions Brief Introduct ion VT-HMI-3081 has been pre-loaded with WinCE5 .0 or embedded Linux image, so that the system can automatically run WinCE 5.0 or embedded Linux when power ed up. 4.1.1 Serial Port Instructions  VT-HMI-5071 As a default debug serial port, COM1 cannot be used by application software nor mally.
  • Page 29: Wince Instructions

    VT-HM I-5071 WinCE Instructions 4.2.1 Windows CE Application Development 4.2.1.1 Development Environment To crea te Win32 and MFC applications with EVC4.0 and cr eate Win32, MFC and C# applications with VS2003、VS2005 and VS2008, the integrated development environment (IDE) can be purchased from the agents of Microsoft Company.
  • Page 30 Therefore, it is a must to ensur e that firmware in the SD card is the required one. You may have to r eturn the product to Vantron for maintenanc e if the updating of Bootloader(adsload.rom)fails, which may cause loss of time and money.
  • Page 31: Instructions For Windows Ce Configuration Files

    VT-HM I-5071 4.2.3 Instructions for Windows CE Config uration Files Windows CE has two configuration files (adsload.hwt/adsload.reg) that can be modified according to your own needs. It is recommended to us e configuration files with our technical support. Instructions are listed below: 4.2.3.1 Adsload.HWT...
  • Page 32 VT-HM I-5071 bitmap files only)  LogoBckGround――designate background color (RGB565 for mat) of Logo displayed in Bootloader. 4.2.3.2 Adsload.REG User’s registry files can be opened by text editor and are standardized, for example: [HKEY_LOCAL_MACHINE\SOFTW ARE\CERDISP] "HostName"="192.168 .8.88" "RefreshTi me"=dword: 32 "AllowRemote"=dword: 0 The system automatically loads when started and you can add system r egistry information therein according to your own needs.
  • Page 33: Notice Of Touch Screen In Wince

    VT-HM I-5071 4.2.4 Notice of Touch Screen in WinCE 4.2.4.1 Touch Screen Calibration To get better touch precision, you need to calibrate befor e using the touch screen. The calibration comprises steps of selecting “Start\Settings\Control Panel” to step into the control panel interface, tapping icon to step into “Stylus Properties”...
  • Page 34 VT-HM I-5071 Stylus Properties Picture 4.2.4.2 Setting Touch screen sensitivity and speed sensitivity The identification precision differenc es between finger touch and pen touch may results in different touch screen identification effec ts. Pen touch has better identification effec t, while finger touch (especially finger pulp touch) gets relatively poorer pr ecision.
  • Page 35: Linux Instructions

    VT-HM I-5071 Linux Instruct ions 4.3.1 Linux Application Development 4.3.1.1 Linux Application Environment The operation environment of VT-HMI application system is a QT/Embedded open system with the following structure: Qt/Embedded Applications QWS Server-Graphic Event Service Qt/Embedded Frame Buffer Input Device Driver Linux Operating System Low-level Hardware Platform Users can develop or transplant Qt/Embedded-based applications to...
  • Page 36: Linux Image Programming

    VT-HM I-5071 4.3.2 Linux Image Programming a) Analyze u-boot and MTD partition to d eter mine programming partition: u-boot config: include/configs/adstrubog5.h MTD driver: drivers/mtd/maps/ads -flash.c #define CO NFIG_BOOTARGS "console=ttyS0,38400 SERI ALGETTY=ttyS0 "\ " SERI ALBAUD=38400" " rw root=/dev/ram initrd=0x80800000,5m" \ "...
  • Page 37 VT-HM I-5071 mx31 small system programming download u-boot: tftp 0x84000000 u-boot.bin // to memory protec t off 0xa0000000 0xa003ffff erase 0xa0000000 +0x40000 cp.b 0x84000000 0xa0000000 0x40000 Download tftp 0x84000000 zI mage // to memory erase 0xa0080000 +0x200000 cp.b 0x84000000 0xa0080000 0x200000 Download ramdisk: tftp 0x84000000 ramdisk.gz erase 0xa0280000 +0x500000...
  • Page 38: Instructions For Linux Configuration Files

    VT-HM I-5071 set bootargs console=ttyS0,38400 SERI ALGETTY=ttyS0 SERI ALBAUD=38400 r w root=/dev/mtdblock4 rootfstype=jffs2 noinitrd mtdparts =flash0:256k(boot),256k(bootvars),2m(zImage),5 m(ramdisk.gz ),-(flashfs1) set zI mage cp.b 0xa0080000 0x84000000 0x200000 // convey to memory from flash set start "bootm 0x84000000" set bootc md "run zImage; run start" 4.3.3 Instructions for Linux Config uration Files Modification and updating of software configurations are...
  • Page 39: Start.txt

    VT-HM I-5071 4.3.4 start.txt The system automatically updates and starts scrip without user’s modification. 4.3.5 tty_config.txt Configure debug s erial port and baud rate for the device.  ${console}: The debug serial port adopted by the device could be set with values such as ttyS0, ttyS1 , ttyS2, etc . ...
  • Page 40: Root_Config.txt

    VT-HM I-5071 4.3.7 root_config.txt Configure items for automatic updating and boot parameters that will be adopted during the boot of updated system, for example: images_to_flash='boot zImage ramdisk.gz flashfs1' is for designating items that need updating. U-boot image: boot Linux knernal image: zImage Linux Ramdisk file system image: ramdisk.gz Linux jffs2 file system image: jffs2 Files designated by image_to_flash variables must exist in the...
  • Page 41: Notice Of Touch Screen In Linux

    VT-HM I-5071 4.3.8 Notice of Touch Screen in Linux 4.3.8.1 Touch Screen Calibration To get better touch control precision, it is needed to calibrate befor e using the touch screen, generally get elec trified on equipment for the first time. The program prompts for automatic calibration if the touch screen is not calibrated.
  • Page 42: Tips

    VT-HM I-5071 Tips Waste Disposal It is recommended to disassemble the device befor e abandoning it in conformity with local regulations. Please ensure that the abandoned batteries are disposed according to local regulations on waste disposal. Do not throw batteries into fire (explosive) or put in common waste canister.
  • Page 43 In the aim of avoiding accidents as far as possible, it is not allowed to replace the system or change components unless with permission and certification. Please contact the technical department of Vantron or local branches for help. Pay attention to caution signs.
  • Page 44 Vantron reserves the right to make necessary changes to this manual without prior notice. No part of this manual may be reprinted or publicly released in forms of photocopy, tape, broadcast, e-document, etc.
  • Page 45 VT-HM I-5071 Chengdu Vantron Technology Ltd. www.vantrontech.com.cn. Phone: (+86)28-85123930 85123931 85157572 85156320 Fax: (+86)28-85123935 E-mail: sales@vantrontech.com.cn...

Table of Contents