VADA - V75-S PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system resistant to sand corrosive action. CONSTRUCTION Pump Body X5 CrNi 1810 (AISI 304) stainless steel...
VADA - V75-S TABLE OF HYDRAULIC PERFORMANCE PUMP PERFORMANCE Absorbed Nominal power L/1’ power Model Voltage µF Stages m3/h Discharge head V75-S 0.75 1~220/240V 49.8 38.1 in meters PUMP DIMENSIONS Dimensions (mm) Weight Model Ø C Free Bore Outlet Port V75-S 1”...
VADA - V75-S INSTALLATION Please pay careful attention to the following warnings signs and indications. Only qualified, licensed personnel should install The pump is designed to be used with clean water pump. The electrical installation shall be in in a residential application. Do not use it with...
It is advisable to fit an automatic level control/float switch to prevent the pump from running without fluids. The V75-S inlet is intentionally raised from the base to prevent the pumping of sediment. To raise this height further, use a length of 3” PVC pipe and insert it into the specially designed base of the pump.
GENERAL CARE AND MAINTENANCE Under normal conditions V75-S pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of abnormal mechanical friction in the pump and/or motor.
VADA - V75-S TROUBLE SHOOTING GUIDE Symptom Cause Remedy The motor will not start, no water is pumped No electricity Ensure that the pump is connected to a live outlet Motor protection tripped Verify the cause and reset the switch. If the...
Page 8
Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.