Replacing electrical resistance ......................... 25 Long shutdown periods ............................. 25 User guide ................................ 25 SPARE PARTS ............................266 To get all the air flow and acoustic performances, refer to the general catalogue and/or the BALI datasheet (available on www.aircalo.fr)
Page 3
In case of an unusual functioning, turn off the unit, remove the electricity supply and contact specialized personnel. Unless particular conditions, Aircalo gives one year parts warranty against defects in conception or production. Are excluded defects of installation and use and also wearing parts and environment condition which damage the smooth functioning of the device that would have not be specified in the order.
2. PRESENTATION Bali cassettes are equipped with EC fans. They are available in section: - 600 x 600 mm - 900 x 900 mm 3. INSTALLATION Choice of the place Avoid the following locations: Exposure to sunbeam Areas near sources of heat. ...
Page 5
Fitting Standard units Use a lift truck to facilitate the installation of the ceiling unit. To avoid damaging the slab, disassemble and store waiting for the end of the installation: - Remove the intake grille. - Remove the screws of the slab. - Remove the panel of the unit.
Page 6
Suspension Structure Mark the position of the suspension rods, water lines, condensate drain pipe, power supply cables and remote control cable. Supporting rods can be fixed, depending on the type of ceiling. Fit suspension brackets supplied with the unit to the threaded rods. ...
Page 7
Ensure there is sufficient space around the unit to service it. Lift unit (without the air panel) with care by its four corners only. Do not lift unit by the condensate drain discharge pipe or by the piping connections. Incline the unit and insert it into the false ceiling.
(mm) A B Bali 60/90 290 10 ou plus Condensate drain The drain pipe has to be covered with an insulating material such as Polyurethane, Protylène or Neoprene, with a thickness of 5 to 10 mm. The unit is fitted with a condensate pump with a 500 mm. lift. ...
4. FRESH AIR CONNECTION The fresh air system for cassette units allows up to 15% of unit airflow to be fresh air intake (per connection). Maximum 2 fresh air connections per unit are allowed. The corners of the cassette allow separate ductwork to be installed for outside air intake (Figure 10) ...
5. HYDRAULIC CONNECTIONS Instructions Size BALI 60 BALI 90 Principal coil 3/4" Female gas 3/4" Female gas Auxiliary coil 1 row 3/4" Female gas 3/4" Female gas Operating limit: Maximum allowable pressure 140 MCE Min ambient air temperature 5 °C, max 32 °C Minimum water temperature 2 °C, max 80 °C Temperature blowing max 60 °C Respect the inlet and outlet water coil as shown on the labels on...
Control valves Standard valves are mounted by the installer. Mounting the motorized control valves can be part of our optional supply. Actuated valves are intended to be supplied with 230 V, average consumption 5 VA. The valves are of the type 2-way or 3-way with bypass. The valves must close the water inlet when there is no power.
External Drain Pan Instructions: Align the two screw holes in the fixing plate to the two holes in the external drain pan. (Figure 8) Make sure the drain pan is horizontal. Tighten the two screws while making sure the external drain pan is installed evenly against the fixing ...
6. ELECTRIC CONNECTIONS The electrical installation of a device must comply with the installation rules in force and carried out by qualified personnel according to the diagrams attached end of document. The supply voltage is 230 V single-phase + earth (operation mini 198 V ; Max: 264 V). ...
7. BOX CONTROL Description Condensate management with valve protection and NC alarm contact. Integrated fan relays for zone control applications. ON/OFF thermostat input and low-voltage modulating fan speed input flexibility. Simple error diagnostic and LED error display. ...
Control Logic Unit Power ON/OFF The unit is turned ON when: One of the fan speed inputs (H/M/L) is ON ON/OFF signal input is ON. The unit is turned OFF only if all of the fan speed inputs (H/M/L) are OFF AND Auto ON/OFF signal input ...
8. LED INDICATION AND ERROR DESCRIPTION SK‐NCGH‐002/003‐ECM Fan speed setting LED indication Condition High speed RED LED ON Normal Medium speed YELLOW LED ON Normal Low speed GREEN LED ON Normal For all units ‐ Green LED blinks Item Item Item Item 1. Check if Ti1 plug is Green LED blinks 4 times, Ti1 sensor unplugged or connected or not. Indoor coil sensor 1 failure stops for 3s damaged. 2. Check if sensor’s resistance is correct or not. Check if the condensate ...
9. SPEED CONTROL BOX Bali cassettes come with 3 fan speeds (Low / Medium / High) factory set. With the speed control box (accessory optional) it is possible to change the fan speed ventilation, especially if the sound level is estimated excessive by the user.
Start-up The unit should not be started up until the system piping has been cleaned and all the air has been purged. Check condensate drain pipe slope. After you have connected the main power supply to the cassette unit, it is necessary to check that the ...
MAINTENANCE Cleaning and maintenance operations must be performed by qualified personnel. Before any work turn the main power switch OFF. Cleaning / Filter removal Cleaning of the filters depends on the conditions of operation of the cassette (approximately every two ...
Fan motor replacement Use a spanner to remove the fan Remove the motor by undoing the 4 bolts and blower then disconnect the fan motor wire connector Replacement control box ...
Condensate pump replacement Remove the drain pan fixture by unscrewing the 8 screws as shown Remove the drain pan fixture and internal drain pan Remove the drain pump or valve...
Replacing electrical resistance Snap in the insulated ring of the electric heater Remark: If the air flow is not sufficient to cool the electrical heater safety, the alimentation is automatically turned OFF. This concern mainly the use at low speed. If necessary fit a higher speed until the electrical heater is correctly cooled.
SPARE PARTS Item Description Item Description 1 Casing Mounting fixture 2 Coil 6‐1 Room sensor 2‐1 Chilled water coil sensor Finger guard 2‐2 Hot water coil sensor 7‐1 Venturi 3 EC Motor Drain pan 4 Fan blower External drain pan 5 Front panel Pump system 5‐1 Front cover 10‐1 Pump 5‐2 Louver 10‐2 Float switch 5‐3 IR receiver 10‐3 Pump pipe‐1 ...