HOMS+OP+/ OHDS+OP+
SDI-to-Optical Converter
and Fiber Optic Multiplexer/
Optical-to-SDI Converter and Fiber Optic
Demultiplexer
Edition A
175-000333-00
Delivering the Moment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HOMS+OP+ and is the answer not in the manual?

Questions and answers

Summary of Contents for Imagine HOMS+OP+

  • Page 1 Installation and Operation Manual HOMS+OP+/ OHDS+OP+ SDI-to-Optical Converter and Fiber Optic Multiplexer/ Optical-to-SDI Converter and Fiber Optic Demultiplexer Edition A 175-000333-00 Delivering the Moment...
  • Page 2: Contact Information

    This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
  • Page 3: Installation And Operation Manual

    HOMS+OP+ SDI-to-Optical Converter and Fiber Optic Multiplexer OHDS+OP+ Optical-to-SDI Converter and Fiber Optic Demultiplexer Installation and Operation Manual Edition A May 2007...
  • Page 5: Table Of Contents

    Contents Preface Manual Information .................v Unpacking/Shipping Information ............vii References .................... viii Safety Standards and Compliances ............x Chapter 1: Introduction Product Description ..................2 General Description ................2 HOMS+OP+ Main Features .............2 OHDS+OP+ Main Features ..............3 Module Types ...................4 Typical Broadcast and Production Applications ......5 Module Descriptions ................6 Front Modules ...................6 Back Modules ...................7...
  • Page 6 Contents Inspecting and Cleaning Fiber Optic Connections ........ 19 Important Points ................19 Inspection and Cleaning Procedure ..........21 Chapter 3: Operation Cross-Functional Parameter Changes ........... 25 Setting Parameters ................. 26 HOMS+OP+ .................. 26 OHDS+OP+ .................. 29 LEDs and Alarms .................. 31 LEDs ....................
  • Page 7: Preface

    Preface Manual Information Purpose This manual details the features, installation procedures, operational procedures, and specifications of the HOMS+OP+ SDI-to-optical converter and fiber optic multiplexer, and of the OHDS+OP+ optical-to-SDI converter and fiber optic demultiplexer. Audience This manual is written for engineers, technicians, and operators responsible for the installation, setup, and/or operation of the HOMS+OP+ SDI-to-optical converter and fiber optic multiplexer and of the OHDS+OP+ optical-to-SDI converter and fiber optic...
  • Page 8 Preface Writing Conventions To enhance your understanding, the authors of this manual have adhered to the following text conventions: Table P-2. Manual Style and Writing Conventions Term or Description Convention Bold Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names.
  • Page 9: Unpacking/Shipping Information

    Preface Unpacking/Shipping Information This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service. 1. Check equipment for any visible damage that may have occurred during transit. 2. Confirm that you have received all items listed on the packing list. 3.
  • Page 10: References

    Preface References ANSI/SMPTE 259M-1997 10-Bit 4:2:2 Component and 4fsc NTSC Composite Digital Signals - Serial Digital Interface (143/177/270/360 Mb/s SDI) SMPTE 344M-2000 540 Mb/s Serial Digital Interface SMPTE 292M-1999 Bit-Serial Digital Interface for High-Definition Television Systems (1.5 Gb/s SDI) SMPTE 297M-2000 Serial Digital Fiber Transmission System for SMPTE 259M- and SMPTE 292M- Signals DVB A010 Rev.1...
  • Page 11 Preface FCC Code of Federal Regulations (CFR) 47, part 15 EN55103-1 EMC Emission Requirements Applies to Professional Audio, Video, Audio-Visual, and Entertainment Lighting Control Apparatus EN55103-2 EMC Immunity Requirements Applies to Professional Audio, Video, Audio-Visual, and Entertainment Lighting Control Apparatus HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 12: Safety Standards And Compliances

    Preface Safety Standards and Compliances “Laser Safety” on page 44 to find the safety standards and compliances for this +OP+ series product. A 6800+ series safety manual is shipped with every FR6802+ Frame Installation and Operation Manual and can be downloaded from our Web site at www.broadcast.harris.com/leitch.
  • Page 13 Preface Waste from Electrical and Electronic Equipment (WEEE) Directive The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products.
  • Page 14 Preface Safety Terms and Symbols This product manual uses the following safety terms and symbols to identify certain conditions or practices. See “Laser Safety” on page 44 and the 6800+ Safety Instructions and Standards Manual for more information. Table P-3. Safety Terms and Symbols WARNING: Identifies conditions or practices that can result in personal injury or loss of life—high voltage is present.
  • Page 15 Chapter 1 Introduction Overview The HOMS+OP+ module is a Coarse Wavelength Division Multiplexing (CWDM) SDI-to-optical converter and fiber optic multiplexer. The OHDS+OP+ is a CWDM optical-to-SDI converter and fiber optic demultiplexer. These modules are designed for high-end multi-channel transport of video in limited “fiber-line” applications. The following topics are described in this chapter: •...
  • Page 16: Chapter 1: Introduction

    Chapter 1: Introduction Product Description General Description The HOMS+OP+ and OHDS+OP+ modules are designed for use in any SD and/or HD environment in which SDI and DVB-ASI signals must cross distances that exceed the normal capabilities of professional video cable. The modules incorporate a passive filter design and feature high optical isolation to ensure low crosstalk.
  • Page 17: Ohds+Op+ Main Features

    Chapter 1: Introduction OHDS+OP+ Main Features OHDS+OP+ features include the following: • Remote control and monitoring via CCS-compliant software and control panels of the following: • Automatic and manual reclocking rate settings and reporting (143, 177, 270, 360, 540 MB/s; and 1.485 Gb/s) •...
  • Page 18: Module Types

    Table 1-1. OHDS+OP+CxxD (Coarse-Wavelength) Modules Four-Channel Module Types Multiplexer Modules Wavelengths • 1290 nm • 1330 nm HOMS+OP+CL4D (lower frequency four-channel multiplexer) • 1310 nm • 1350 nm • 1550 nm • 1590 nm HOMS+OP+CU4D (upper frequency four-channel multiplexer) •...
  • Page 19: Typical Broadcast And Production Applications

    Chapter 1: Introduction Typical Broadcast and Production Applications HOMS+OP+ and OHDS+OP+ products can be used in broadcast, cable, production, educational, and auditorium applications where a low-cost method of distributing serial digital video signals is required. Typical applications include sending signals from a studio, remote truck, or other production facility to the transmission site/facility.
  • Page 20: Module Descriptions

    Chapter 1: Introduction Module Descriptions Front Modules Figure 1-1. HOMS+OP+ and OHDS+OP+ Front Module (OHDS+OP+ shown) HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 21: Back Modules

    Chapter 1: Introduction Back Modules Figure 1-2 shows the connections and wavelengths for those connections in the four-and eight-channel back modules of the HOMS+OP+ and OHDS+OP+. Table 1-2. HOMS+OP+ (4- and 8-channel) and OHDS+OP+ (8-channel) Lower/Upper BNC Connector Wavelength 1290/1610 1310/1590 1330/1570 1350/1550...
  • Page 22: Signal Flow

    ReClk Laser1 ReClk Laser2 ReClk Laser3 Fiber optic ReClk Laser4 CWDM filter ReClk Laser5 ReClk Laser6 ReClk Laser7 ReClk Laser8 CCS control/ Microcontroller monitoring port Card edge LEDs/jumpers Figure 1-3. HOMS+OP+Block Diagram HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 23 Chapter 1: Introduction Figure 1-4. OHDS+OP+ Block Diagram HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 24 Chapter 1: Introduction 16-Channel L -U-L-U (lower-upper-lower-upper wavelength system ) = 8 upper + 8 lower Ch 2 Optical input Ch 2 Ch 1 Optical Express Optical Out express in ASI/SD/HD Ch 3 1270 nm ASI/SD/HD 1290 nm ASI/SD/HD ASI/SD /HD 1310 nm Ch 6 ASI/SD/HD...
  • Page 25 Chapter 2 Installation Overview This chapter describes the HOMS+OP+ and OHDS+OP+module installation process, including the following topics: • “Maximum Frame Power Ratings” on page 12 • “Unpacking the Module” on page 13 • “Setting Jumpers” on page 13 • “Installing and Removing the Modules” on page 14 See the FR6802+ Frame Installation and Operation Manual for information about installing and operating an FR6802+X(F) frame and its components.
  • Page 26: Chapter 2: Installation

    Dissipation OHDS+OP+ Type Supply Dissipation Slots Per Slot Requirements • 6W FR6802+XF 120 W (HOMS+OP+xx4D FR6802+XF48 105 W 5.25 W OHDS+OP+xx4D) FR6802+QXF AC or 120 W • 12 W (HOMS+OP+xx8D OHDS+OP+xx8D) * Each front module requires two of these slots. Therefore, to calculate the maximum power dissipation available per module, double the rating shown in the Max.
  • Page 27: Unpacking The Module

    Chapter 2: Installation Unpacking the Module Preparing the Product for Installation Before you install HOMS+OP+ or OHDS+OP+ modules, perform the following: • Check the equipment for any visible damage that may have occurred during transit. • Confirm receipt of all items on the packing list. See “Checking the Packing List”...
  • Page 28: Installing And Removing The Modules

    Chapter 2: Installation Installing and Removing the Modules Installation Overview Front and back modules in the OPTO+ series have plastic caps that protect the fragile laser connections from damage. You must remove these protective covers before you install the back and front modules (see Figure 2-1).
  • Page 29: Back Module Installation

    Chapter 2: Installation Back Module Installation Follow these steps to install the back module into an FR6802+XF, FR6802+XF48, or FR6802+QXF frame: 1. Power down the frame. CAUTION Although front modules can be hot-swapped, back modules can only be safely installed or removed when the frame’s power is off. Ensure the front module has been removed before you install the back module.
  • Page 30: Front Module Installation

    Chapter 2: Installation Front Module Installation HOMS+OP+ and OHDS+OP+ modules have “locking” latches (see Figure 2-2). On the left side, the latch is in the down (locked) position; the latch on the right is in the up (unlocked) position. Both front modules are hot-swappable and can be installed with the power supply either turned on, or turned off.
  • Page 31 Chapter 2: Installation 3. Gently remove the outer and inner protective caps from the laser connections. (see Figure 2-1 on page 14). CAUTION Microscopic dust or other contaminants can seriously impair or disable a fiber optic network. Observe strict cleaning procedures. Do not touch the end of the fiber.
  • Page 32: Removing Modules

    Chapter 2: Installation Removing Modules NOTE The removal steps provided here are similar to those outlined in your FR6802 Frame Installation and Operation Manual. Refer to that manual for detailed information about installing and operating an FR6802 frame and its components. Front Module Follow these steps to remove a front module from an FR6802+ frame: 1.
  • Page 33: Inspecting And Cleaning Fiber Optic Connections

    Chapter 2: Installation Inspecting and Cleaning Fiber Optic Connections Small amounts of microscopic dust or other contaminants can seriously impair or disable a fiber optic network. To ensure that your network operates reliably, you must carefully inspect and clean each connection when installing OPTO+ products.
  • Page 34 Chapter 2: Installation • Never touch the dispenser tip of an alcohol bottle or any clean portion of a tissue or swab. • Use care when handling the fiber; do not twist or pull. • Keep your cleaning fluids away from open flame or spark. Figure 2-3 describes the acceptable limits of defects in a fiber connection.
  • Page 35: Inspection And Cleaning Procedure

    Chapter 2: Installation Inspection and Cleaning Procedure Inspection To inspect and clean the fibers, follow these steps: 1. Ensure the fiber is not “live.” WARNING Eye damage may occur if an optical instrument such as a microscope, magnifying glass, or eye loupe is used to stare at an energized fiber end.
  • Page 36 Chapter 2: Installation Wet Cleaning Using 99% isopropyl alcohol and lint-free wipes, follow these steps to wet clean the fiber: 1. Fold the wipe into a square, about 4 to 8 layers thick. 2. Moisten one section of the lint-free wipe with one drop of 99% alcohol, ensuring that a portion of the wipe remains dry.
  • Page 37 Chapter 3 Operation Overview This chapter describes the operation of the HOMS+OP+ and OHDS+OP+ modules using CCS-enabled software or control panels. (Most of the parameter settings can be controlled at the card edge.) See the operation manuals or online help associated with the CCS products for more information on monitoring and control.
  • Page 38: Chapter 3: Operation

    Chapter 3: Operation Operation Notes When setting the control parameters on the HOMS+OP+ and OHDS+OP+ modules, observe the following: • If you make changes to certain parameters, other related parameters may be affected also. See “Cross-Functional Parameter Changes” on page 25 for more information.
  • Page 39: Cross-Functional Parameter Changes

    Chapter 3: Operation Cross-Functional Parameter Changes In some situations, when certain parameters are changed, other changes are forced in associated parameters. Table 3-1 Table 3-2 describe those changes in the HOMS+OP+ and OHDS+OP+, respectively. The value of x in Table 3-1 Table 3-2 is 1, 2, 3, 4, 5, 6, 7, or 8.
  • Page 40: Setting Parameters

    Chapter 3: Operation Setting Parameters HOMS+OP+ Table 3-3 (below) and Table 3-4 on page 28 list the available HOMS+OP+ parameter options (four-channel and eight-channel, respectively). You must use CCS-enabled software or control panels to access most of these parameters (Transmitter Enable can also be controlled at the card-edge).
  • Page 41 Chapter 3: Operation Table 3-3. HOMS+OP+ Parameters (Four-Channel L4 and U4 Versions) Parameter Name Function Options • Not present Ch-x SDI Present [RO] Detects the presence of signals at inputs 1 to 4 • Present • Disable Ch-x Laser Enable Enables the fiber optic transmitters for channels 1 to 4 •...
  • Page 42 Chapter 3: Operation Table 3-4. HOMS+OP+ Parameters (Eight-Channel L8 and U8 Versions) Parameter Name Function Options • Auto* Ch-x Reclock Mode Sets the data rate for inputs 1 to 8 • 143 • 177 • 270 • 360 • 540 •...
  • Page 43: Ohds+Op

    Chapter 3: Operation OHDS+OP+ Table 3-5 Table 3-6 on page 30 list the available OHDS+OP+ parameter options (four-channel and eight-channel, respectively).You must use CCS-enabled software or control panels to access the parameters (there are no card-edge controls on this product). Using CCS, you can also view the current firmware and hardware versions of the module.
  • Page 44 Chapter 3: Operation Table 3-6. OHDS+OP+ Parameters (Eight-Channel L8 and U8 Versions) Parameter Name Function Options • Auto* Ch-x Reclock Mode Sets the data rate for inputs 1 to 8 • 143 • 177 • 270 • 360 • 540 •...
  • Page 45: Leds And Alarms

    Chapter 3: Operation LEDs and Alarms LEDs The Module Status LED is located in the left corner of the card edge on HOMS+OP+ and OHDS+OP+ front modules (see Figure 3-1 Figure 3-2 on page 33). On the HOMS+OP+, the Channel Status LEDs (Laser Transmitting, Lock, and Presence) are immediately to the right of the Module Status LED.
  • Page 46: Alarms

    Chapter 3: Operation Alarms Alarms on the HOMS+OP+ and OHDS+OP+ are logged and monitored within CCS-enabled applications and control panels. See Table 3-8 for alarm details. Table 3-8. HOMS+OP+ and OHDS+OP+ Alarms Alarm Name of Alarm Meaning Level HOMS+OP+ Module Ch-x Loss of Input Major The SDI input on the designated channel is missing.
  • Page 47 Chapter 3: Operation Channel LEDs for Laser Module Status Transmitting, SD Lock and SD Present Figure 3-1. HOMS+OP+ LEDs Channel LEDs for SD Lock Module Status and SD Present Figure 3-2. OHDS+OP+ LEDs HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 48 Chapter 3: Operation HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 49: Specifications

    Chapter 4 Specifications Overview The following specification information appears in this chapter: • “Laser Output” on page 36 • “Inputs” on page 37 • “Outputs” on page 38 • “Power Consumption” on page 41 Specifications and designs are subject to change without notice. HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 50: Chapter 4: Specifications

    Table 4-1. Optical Specifications for Laser Modules Laser Product Wavelength Optical Output Pulse Class / Laser Laser Module Model (nm) Power (mW) Duration Radiation Class HOMS+OP+CL4D 1290 – 1350 Continuous HOMS+OP+CL8D 1270 – 1450 Continuous HOMS+OP+CU4D 1550 – 1610 Continuous HOMS+OP+CU8D 1470 – 1610 Continuous...
  • Page 51: Inputs

    Chapter 4: Specifications Inputs HOMS+OP+ Table 4-2. HOMS+OP+ Input Specifications Item Specification Number of inputs 4 or 8 Signal type HD-SDI, SD-SDI, ASI Connector BNC per IEC169-8 Impedance 75Ω Return loss >17dB 5MHz to 1.5GHz Maximum signal level >=0.88Vp-p • 0-300m Belden 1694A for Cable equalization 270Mb/s SD-SDI •...
  • Page 52: Outputs

    Chapter 4: Specifications Outputs HOMS+OP+ Table 4-4. HOMS+OP+ Optical Outputs Item Specification Number of outputs Wavelength CWDM 16 channels Connector SC/PC per IEC 61754-4-1 Output power -3 dBm per channel (typical) Extinction ratio >8dB in each channel Express port optical insertion loss 4 channel: <2dB typical 8 channel: <3dB typical HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 53: Ohds+Op

    Chapter 4: Specifications OHDS+OP+ Table 4-5. HD Electrical Output Specifications Item Specification Number of outputs Signal type HD-SDI, ASI Connector BNC per IEC169-8 Impedance 75Ω Return loss >17 dB 5 MHz to 1.5 GHz 800 mVp-p ± 10% Signal amplitude 0.0 V ±...
  • Page 54: Inputs To Outputs Performance (Homs+Op+ To Ohds+Op+)

    Chapter 4: Specifications Inputs to Outputs Performance (HOMS+OP+ to OHDS+OP+) Table 4-7. Inputs to Outputs Performance (HOMS+OP+ to OHDS+OP+) Item Specification Number of inputs 8 or 4 Number of outputs 8 or 4 Adjacent channel isolation >30dB (demux) Non-adjacent channel isolation >40dB (demux) Performance temperature...
  • Page 55: Power Consumption

    Chapter 4: Specifications Power Consumption Table 4-8. Power Consumption Specifications Item Specification HOMS+OP+xx4D HOMS+OP+xx8D 12 W OHDS+OP+xx4D OHDS+OP+xx8D 12 W Start-Up Time Start-up time for HOMS+OP+ and OHDS+OP+ modules is <10 seconds. Temperature Table 4-9. Temperature Specifications Item Specification Operating temperature 14°...
  • Page 56 Chapter 4: Specifications HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 57 Appendix A Laser Safety Guidelines Overview This section describes important safety considerations when using laser modules. The following topics are included: • “Laser Safety” on page 44 • “Labels” on page 46 HOMS+OP+ and OHDS+OP+ Installation and Operation Manual...
  • Page 58: Appendix A: Laser Safety Guidelines

    Appendix A: Laser Safety Guidelines Laser Safety WARNING Use of controls, adjustments, and procedures other than those specified in this document may result in hazardous laser radiation exposure. Optical fiber telecommunication systems use semiconductor laser transmitters that emit infrared light that is normally not visible to the human eye.
  • Page 59: Precautions For Unenclosed Systems

    Appendix A: Laser Safety Guidelines Under normal operating conditions, optical fiber telecommunication systems are completely enclosed; nonetheless, observe the following precautions: 1. Do not stare into optical connectors or broken fibers. 2. Ensure technicians have satisfactorily completed an approved training course before performing installation or maintenance. 3.
  • Page 60: Labels

    Appendix A: Laser Safety Guidelines Labels The label shown in Figure A-1 is applicable to Class 1 laser products. CLASS 1 LASER PRODUCT IEC 60825-1:1993 + A1:1997 + A2:2001 CAUTION: INVISIBLE LASER RADIATION WHEN OPEN. AVOID EXPOSURE TO THE BEAM. Figure A-1.
  • Page 61: Index

    Index Keywords Alarms Input specifications Applications of the product Inspecting and cleaning fiber connections 19–22 Back modules 7, 15, 18 Jumper settings Block diagram 8–9 Laser CCS parameters 26–30 input specifications Channel Status LEDs output specifications 36, 38–39 Cleaning fiber optic connections 19–22 precautions 14–17, 44–46...
  • Page 62 Index Operating temperature specifications Setting jumpers Operation notes Shipping information Output specifications 36, 38–39 Signal flow diagrams 8–9 Specifications input output 36, 38–39 Parameter options power, start-up time, and temperature HOMS+OP+ 26–27 OHDS+OP+ 29–30 Performance temperature specification Power Temperature specifications consumption Transmitter Enable parameter ratings...