Summary of Contents for Voltronic Power SCC-MPPT 300W
Page 1
20 hours Table 6: Power consumption of home appliances table* Appliances Power Daily usage hours Daily watt hours Consumption (W) used (Wh) Lighting bulb Energy saving SCC-MPPT 300W SCC-MPPT 600W bulb Electric fan Washing machine Air conditioner 4800 Freezer 9600 PC with 17”...
Terminal block for solar panel connection Model Nominal Battery Voltage Typical Current (Amp) Terminal block for battery connection SCC-MPPT 300W 12 V 25 A Terminal block for load connection SCC-MPPT 600W 12V or 24 V (auto sensing)
DC breaker off or do not install the DC fuse. Voltage (max.) Power 1) Multiple batteries in series connection (Refer to Fig. 5): All batteries SCC-MPPT 300W 50 VDC 300 W must be equal in voltage and amp hour capacity. The sum of their voltages...
Status, LED/LCD Display and Audible Alarms Status Alarm Polarity reversal on solar module Yellow LED on. connection. Fig. 9 Polarity reversal on CAUTION: It may not cause any damage to solar module or unit when connecting Red LED on. battery connection. polarity reversals.
4. Specifications Model SCC-MPPT 300W SCC-MPPT 600W Problem Possible Cause Solutions INPUT F1 fault code displays on Battery wires are not Check if battery wires MPPT Range @ Operating 15 V ~ 37 V @ 12 V 30 V ~ 66 V @ 24 V LCD panel.