The I/O signal of the LSI is detailed in the following table.
Pin No.
Signal
1-2
VL2-VL1
3-6
AN7-AN4
7
AN3
8
AN2
9
AN1
10
AN0
11-13
P57-P55
14
CNTR0
15
P53
16
P52
17
P51
18
P50
19
P47
20
P46
21
P45
22-23
P44-P43
24
INT0
DESCRIPTION OF LSI
I/O
IN
Power source voltage input terminal.
Standard voltage for LCD.
IN
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
IN
Signal coming from touch key.
When either G13 line on key matrix is touched, a corresponding signal out of P20 - P27
will be input into AN3. When no key is touched, the signal is held at "H" level.
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door Open "L" level (-5V).
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the A/
D converter built into the LSI.
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
OUT
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
OUT
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to the
RY1 driving circuit and RY2 control circuit.
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cook-
ing and "H" level while not cooking. In other
cooking modes (variable cooking) the signal
turns to "H" level and "L" level in repetition
according to the power level.
IN
Signal similar to AN3.
When either G13 line on key matrix is touched, a corresponding signal will be input into
P46.
OUT
Terminal not used.
IN
Signal similar to AN3.
When either G12 line on key matrix is touched, a corresponding signal will be input into
P45.
OUT
Terminal not used.
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
Description
A
B
Maximum
output
70% of maximum
output
22
0.1 sec.
H : GND
L : -5V
2.0 sec.
H : GND
L : -5V
16.7 msec.
H : GND
L : -5V
During cooking
OFF
H : GND
ON
L : -5V
OFF
OFF
H : GND
24 sec.
8 sec.
ON
L : -5V
16.7 msec.
H : GND
L : -5V