Bosch MIC612 Installation Manual page 25

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

MIC612 Thermal Camera
NOTICE!
You must connect the overall shield drain wire of the composite cable to the power supply
chassis in order to ground the chassis. Crimp the drain wire to the ring terminal lug attached
to the mounting screw of the PCB located to the right of BNC socket CN3 (Video Switched).
Refer to Figure 4.1 for the location of the screw.
* If connecting a heater, see Section 4.3.5 Commissioning the Camera with Heater Option Fitted.
19. Slide back the cable so that the shield is in the middle of the gland.
20. Tighten the cable gland so that it grips firmly the shielded composite cable. It is
21. If necessary, connect a tamper switch to terminal block HD2.
22. Feed the Video Out (coax) cable through the top-left M12 cable gland (item 1,
23. Connect the Video Out cable to BNC socket CN1.
24. For dual video output only: If needed, remove the blanking plug that covers the hole for
25. Feed telemetry cable through the bottom-right M12 cable gland (item 4, Figure 4.5).
26. Connect head-end RS-485 control to terminal block HD5, as indicated in the table below:
Note: The terminal block is positioned with the screw terminals on the left, next to the fuses.
Pins are numbered from top to bottom in that orientation. Non-IR PSU PCBs are marked.
27. If connecting to additional add-on cards (for example, a card for 8-input alarms (MIC-
NOTICE!
For installation of the MIC 8-input Alarm Card (MIC-ALM) or Biphase converter (MIC-BP4),
please refer to their respective manuals.
28. After wiring is complete, connect the power supply to the power source.
29. Verify that the following LEDs are lit:
30. Re-attach the enclosure lid and tighten the four (4) captive screws on the cover door to
Bosch Security Systems, Inc.
important that the braided cable screen engages with the internal clamps of the cable
gland to ensure correct EMC protection.
Figure 4.5). Crimp the end of the cable with a BNC terminal connector.
the bottom-left M12 cable gland (item 3, Figure 4.5). Feed a second Video Out cable
through the cable gland, and then connect the switched Video Out cable to BNC socket
CN3. This second cable provides control for video from both the optical camera and the
thermal camera; users can switch between the two cameras.
PCB Marking
Telemetry
(non-IR PCBs)
Signal Name
RxB
Rx +
RxA
Rx -
0V
Ground
TxA
Tx -
TxA
Tx +
516ALM) or for 8-input alarms plus washer pump drive (MIC-ALM), and/or a Biphase card
(MIC-BP4)), remove the second blanking plug that covers one of the holes for an M12
cable gland (item 3, Figure 4.5). Attach the supplied M12 gland. Make the appropriate
connections to plug-in terminal CN2.
LED
Description
LED 2 18 VAC power on to camera
LED 4 Power on for optional heater
LED 3 18 VAC power on camera
LED 5 Power on for optional heater
ensure that the enclosure is watertight.
Installation Manual
Connection Description /
Function
RS485+ to camera
RS485- to camera
0V from control room
RS485- to control room
RS485+ to control room
Installation | en
Pin Number
1
2
3
4
5
F.01U.249.416 | 1.1 | 2012.03
25