Table of Content Getting to Know Your Switch ................ 3 About the LNP-600N/LNP-602N Managed Industrial Switch ........3 Software Features ....................3 Hardware Features ....................3 Hardware Installation ..................4 Installing Switch on DIN-Rail ..................4 2.1.1 Mount LNP-600N/LNP-602N Series on DIN-Rail ..........4 Wall Mounting Installation ..................
Page 3
Fault Alarm ....................31 5.1.8 Front Panel ......................36 5.1.9 Save Configuration .................... 36 5.1.10 LLDP ......................37 5.1.11 Power over Ethernet (P.O.E.) ................ 37 5.1.12 Auto-Ping Check .................... 39 5.1.13 Schedule ......................40 Technical Specifications ................41 Aaxeon Technologies, LLC...
About the LNP-600N/LNP-602N Managed Industrial Switch The LNP-600N/LNP-602N switch is a cost-effective and powerful industrial switch with many features. These switches can work under wide temperature and dusty environment and humid condition. The LNP-600N/LNP-602N support Power over Ethernet, a system to transmit electrical power with data to remote devices over standard twisted-pair cable.
Each switch has a DIN-Rail kit on rear panel. The DIN-Rail kit helps switch to fix on the DIN-Rail. It is easy to install the switch on the DIN-Rail: 2.1.1 Mount LNP-600N/LNP-602N Series on DIN-Rail Step 1: Slant the switch and mount the metal spring to DIN-Rail.
The following steps show how to mount the switch on the wall: 2.2.1 Mount LNP-600N/LNP-602N Series on wall Step 1: Remove DIN-Rail kit. Step 2: Use 6 screws that can be found in the package to combine the wall mount panel.
Page 7
The screws specification shows in the following two pictures. In order to prevent switches from any damage, the screws should not be larger than the size that is used in the switch. Pozidrive Step 3: Mount the combined switch on the wall. Aaxeon Technologies, LLC...
LNP600N / LNP-602N User’s Manual ardware Overview Front Panel The following table describes the labels that stick on the LNP-600N/LNP-602N. Port Description 10/100 RJ-45 fast 10/100Base-T(X) RJ-45 fast Ethernet ports support auto-negotiation. Ethernet ports Default Setting : Speed: auto Duplex: auto...
Page 9
7. Reset button. Push the button 3 seconds for reset; 5 seconds for factory default. 8. 10/100Base-T(X) Ethernet ports. 9. LED for Ethernet ports status. 10. 10/100Base-T(X) Ethernet ports. 11. LED for Ethernet ports status. 12. LED for P.O.E. power supplied. Aaxeon Technologies, LLC...
Page 10
7. Reset button. Push the button 3 seconds for reset; 5 seconds for factory default. 8. 10/100Base-T(X) Ethernet ports. 9. LED for Ethernet ports status. 10. 100BaseFX fiber port. 11. LNK/ACT LED for fiber port. 12. LED for P.O.E. power supplied. Aaxeon Technologies, LLC...
Data transmitted. Amber Port link up. Bottom Panel The bottom panel components of LNP-600N/LNP-602N are showed as below: 1. Terminal block includes: PWR1, PWR2 (+48V DC) and Relay output (1A@24VDC). 2. Power jack for PWR3 (+48VDC). LNP-600N/LNP-602N power connection Aaxeon Technologies, LLC...
LNP600N / LNP-602N User’s Manual Rear Panel The rear panel components of LNP-600N/LNP-602N are showed as below: 1. Screw holes for wall mount kit. 2. Din-Rail kit Aaxeon Technologies, LLC...
Ethernet Cables The LNP-600N/LNP-602N switches have standard Ethernet ports. According to the link type, the switches use CAT 3, 4, 5,5e UTP cables to connect to any other network device (PCs, servers, switches, routers, or hubs). Please refer to the following table for cable specifications.
(0 to 2 km, 1310 nm in 50/125 µm, 62.5/125 µm) and single-mode (9/125 µm) with SC connector. Please remember that the TX port of Switch A should be connected to the RX port of Switch B. Switch A TX RX Fiber cord Switch B Aaxeon Technologies, LLC...
The default value is as below: IP Address: 192.168.10.1 Subnet Mask: 255.255.255.0 Default Gateway: 192.168.10.254 User Name: admin Password: admin System Login 1. Launch the Internet Explorer. 2. Type http:// and the IP address of the switch. Press “Enter”. Aaxeon Technologies, LLC...
Page 16
3. The login screen appears. 4. Key in the username and password. The default username and password is “admin”. 5. Click “Enter” or “OK” button, then the main interface of the Web-based management appears. Login screen Main Interface Main interface Aaxeon Technologies, LLC...
Display the switch’s firmware version Firmware Version Kernel Version Display the kernel software version MAC Address Display the unique hardware address assigned by manufacturer (default) 5.1.2.2 Admin Password Change web management login username and password for the management security issue Aaxeon Technologies, LLC...
You can configure the IP Settings and DHCP client function through IP configuration. IP Configuration interface The following table describes the labels in this screen. Label Description DHCP Client To enable or disable the DHCP client function. When DHCP Aaxeon Technologies, LLC...
Assign the primary DNS IP address Assign the secondary DNS IP address DNS2 Apply Click “Apply” to activate the configurations. 5.1.2.4 SNTP Configuration The SNTP (Simple Network Time Protocol) settings allow you to synchronize switch clocks in the Internet. SNTP Configuration interface Aaxeon Technologies, LLC...
Page 20
PDT - Pacific Daylight PST - Pacific Standard -8 hours 4 am ADT - Alaskan Daylight ALA - Alaskan Standard -9 hours 3 am HAW - Hawaiian Standard -10 hours 2 am Nome, Alaska -11 hours 1 am Aaxeon Technologies, LLC...
Page 21
Set up the Daylight Saving beginning time and Daylight Saving Period ending time. Both will be different each year. Daylight Saving Set up the offset time. Offset Switch Timer Display the switch current time. Apply Click “Apply” to activate the configurations. Aaxeon Technologies, LLC...
Click “backup” to backup the configurations. 5.1.2.6 Upgrade Firmware Upgrade Firmware allows you to update the switch firmware. Before updating, make sure you have your TFTP server ready and the firmware image is on the TFTP server. Update Firmware interface Aaxeon Technologies, LLC...
You can select “Keep current IP address setting” and “Keep current username & password” to prevent IP and username & password from default. 5.1.2.8 System Reboot System Reboot interface Aaxeon Technologies, LLC...
Speed/Duplex mode. Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred. Apply Click “Apply” to activate the configurations. 5.1.3.2 Port Status The following information provides the current port status. Port Status interface Aaxeon Technologies, LLC...
The Fast Recovery Mode can be set to connect multiple ports to one or more switches. The LNP-600N/LNP-602N with its fast recovery mode will provide redundant links. Fast Recovery mode supports 4 priorities, only the first priority will be the act port, the other ports configured with other priority will be the backup ports.
Page 26
Link to Control Port of the switch of the same ring. Control Port used to transmit control signals. Dual Homing Mark to enable Dual Homing. By selecting Dual Homing mode, Redundant Ring will be connected to normal switches through Aaxeon Technologies, LLC...
It provides faster spanning tree convergence after a topology change. The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol. RSTP setting You can enable/disable the RSTP function, and set the parameters for each port. RSTP Setting interface Aaxeon Technologies, LLC...
Page 28
To configure the port as an edge port, set the port to “True”. Admin Non STP The port includes the STP mathematic calculation. True is not including STP mathematic calculation. False is including the STP mathematic calculation. Aaxeon Technologies, LLC...
Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP. 5.1.5.1 SNMP – Agent Setting You can set SNMP agent related information by Agent Setting Function. Aaxeon Technologies, LLC...
If no trap manager is defined, no traps will issue. Create a trap manager by entering the IP address of the station and a community string. To define management stations as trap manager and enter SNMP community strings and selects the SNMP version. Aaxeon Technologies, LLC...
Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belonging to another single VLAN. If the port-based VLAN enabled, the VLAN-tagging is ignored. VLAN Configuration – Port Based VLAN interface Aaxeon Technologies, LLC...
Fault alarm interface System Warning – SYSLOG Setting The SYSLOG is a protocol to transmit event notification messages across networks. Please refer to RFC 3164 - The BSD SYSLOG Protocol Aaxeon Technologies, LLC...
Page 33
SYSLOG Server IP The remote SYSLOG Server IP address. Address Apply Click “Apply” to activate the configurations. Help Show help file. System Event LOG If system log client is enabled, the system event logs will show in this table. Aaxeon Technologies, LLC...
Page 34
Show help file. System Warning – SMTP Setting The SMTP is Short for Simple Mail Transfer Protocol. It is a protocol for e-mail transmission across the Internet. Please refer to RFC 821 - Simple Mail Transfer Protocol. Aaxeon Technologies, LLC...
Page 35
SYSLOG and SMTP are the two warning methods that supported by the system. Check the corresponding box to enable system event warning method you wish to choose. Please note that the checkbox can not be checked when SYSLOG or SMTP is disabled. Aaxeon Technologies, LLC...
Page 36
Redundant Ring Alert when Redundant Ring topology change Topology Change Port Event Disable Link Up Link Down Link Up & Link Down Apply Click “Apply” to activate the configurations. Help Show help file. Aaxeon Technologies, LLC...
Otherwise, the current configuration will be lost when power off or system reset. System Configuration interface The following table describes the labels in this screen. Label Description Save Save all configurations. Help Show help file. Aaxeon Technologies, LLC...
Click “Apply” to activate the configurations. Help Show help file. 5.1.11 Power over Ethernet (P.O.E.) The following interface is the PoE setting interface. There are 4 ports (port 1 to port 4) act as PSE (Power Supply Equipment) ports. Aaxeon Technologies, LLC...
Page 39
Set port priority for the P.O.E. power management. 1 = C (critical), Priority 2 = H (High), 3 = L (Low) Power Limit Set the power limit value. The maximum value must less 15400 Mode Display the PD current operation mode status Aaxeon Technologies, LLC...
You can appoint to want to control P.O.E port number Port Ping IP Address Set up IP Address Interval Time Spacing interval to set up Ping Set up the number of times of ping Retry Time Failure Action Set up movements wanted to carry out Aaxeon Technologies, LLC...
The following table describes the labels in this screen. Label Description Setting action port Schedule on Schedule mode enable or disable Schedule mode Select all Select all Data & Time Hour Set up enable Time Sunday ~ Saturday Set up enable Data Aaxeon Technologies, LLC...
Per Unit : Power x 3(Green) RJ45 Ports: Per Port : Link/Activity(Green/Blinking Green), Full duplex(Amber) P.O.E. LED: P.O.E. power supplied(Green) Fiber Ports: Per Port : Activity(Green), Link (Amber) Power Requirements Power Input Voltage PWR1/2: +48V DC in 7 pin Terminal block Aaxeon Technologies, LLC...
Page 43
Casing IP-30 protection Regulatory Approvals Regulatory Approvals FCC Part 15, CISPER (EN55022) class A EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS) Shock IEC 60068-2-27 Free Fall IEC 60068-2-32 Vibration IEC 60068-2-6 Warranty 5 years Aaxeon Technologies, LLC...