SELF-DIAGNOSIS
DISPLAY
Mechanism Mode Display/ Head Output Drop Warning Display/Cylinder
Rotation Accumulated
Time Display
This unit displays the diagnosis contents of abnormalities
and the mechanism,
mode on its display panel in 2-digit numbers.
When the head playback output has dropped, the "V sign will be blinked. Some models (listed later) will also display the cylinder
rotation accumulated
time.
These display shows the outline of the problems. Use it as a reference when servicing the unit.
1.
Self-Diagnosis
Contentes and Mechanism
Mode Display
.
When the STOP button on the remote control is pressed for about 10 seconds continuously,
the self-diagnosis
number will be
displayed on the reception channel display of the display panel and number indicating the failed mechanism mode (changed mode
when being shifted) on the tape counter "seconds" display for 10 seconds each.
During self-diagnosis
display, displays other than the diagnosis number/mechanism
mode number and the cylinder accumulated
rotation time display described later (some models only) will be turned off and when displays end, the normal display will be
returned automatically.
Refer to "Self-Diagnosis
Contents"
for the self-diagnosis
numbers
and the "Mechanism
Mode Display Contents"
for the
mechanism mode numbers.
When the "O" button on the remote control unit is pressed during display, and clearing the self-diagnosis
display and mechanism
-
Self-Diagnosis
number
Mechanism
mode number
(Reception channel display)
(Tape counter "Seconds" display)
Self-Diagnosis Contents
No.
00
01
02
03
04
05
Problem
Main Possible
Cause
Mechanism
Operations
and
State After Occurrence
There is no abnormality
in the mechanism.
The cylinder motor does not rotate.
The take-up reel does not rotate.
The capstan motor does not rotate.
The tape cannot be loaded with the
cassette inserted.
(But unloading can be performed.)
Tape loading and unloading
cannot
be performed
with the cassette
in-
serted.
. The cylinder motor is faulty.
The control of the cylinder motor is
faulty.
The taDe winds around the cylinder.
The take-up reel is caught.
The reel belt is faulty.
The take-up torque has decreased.
The capstan motor is faulty.
The control of the capstan motor is
faulty.
Error in the operations
of the tape
loading mechanism.
Foreign particles in the tape load-
ing mechanism.
The tape end sensor is faulty.
The reel brake of the tape cassette
has not been released.
The tape guide is caught.
The loading motor is faulty.
The control of the loading motor is
faulty.
Shifts to the STOP mode.
Shifts to the STOP mode.
Shifts to the STOP mode.
Unloads, shifts to the INITIAL mode,
and the power goes off.
The power is forcibly turned off with
the mechanism at its current position.
.-
.-
–2–