®
Hinged canopy door
Reset button
Power
supply
USB
Ethernet
Integrated
RS-232
ports (2)
ProLink.z
Quick Reference Guide
71-500006-19 V1.0
IR/Sense input
Routable IR output
ports (6)
Installation & Operation
Power
The included AC adapter should be connected to the POWER jack on the ProLink.z. Use only the supplied AC adapter to power the
ProLink.z. Using a different power adapter could result in damage to the unit or poor performance.
Adjusting IR Output level
The IR output level can be independently adjusted for each of the output ports. The ProLink.z is shipped with the IR gain set to the
optimum level for most equipment, and it should only need to be adjusted if the attached equipment is not responding reliably.
If adjustment is needed, rotate the IR output controls on the frontside of the unit clockwise for higher output power, or counter-
clockwise for lower output power.
USB Port
Used to program the ProLink.z and/or update its firmware.
Ethernet
This RJ-45 port allows connection to a 10/100 Base-T Ethernet network (LAN) for programming control, and two-way communication
with compatible devices. Network settings such as the IP address are configurable within Pro Control Studio.
Connecting IR Emitters To Output Ports
The IR emitter ports on the ProLink.z are compatible with industry standard infrared emitters and connecting blocks. Each output
port is capable of driving up to four infrared emitters directly. More than four infrared emitters per port requires an amplified
connecting block. A connecting block can be wired up to 500 feet (150 meters) away from the unit using #22 AWG (minimum) wire.
RJ-45 to DB-9 Pinout
DB-9 Connector Pin Out
RJ-45 Connector Pin Out
Pin Signal Signal
Pin Signal Signal
Name Description
IR output level
1
DCD
Carrier Detect
1
2
RXD
Receive Data
adjustments
2
3
TXD
Transmit Data
4
DTR
Data Terminal
3
Ready
5
GND
Signal Ground/
4
Common
6
DSR
Data Set
5
Ready
6
7
RTS
Request To
Send
7
8
CTS
Clear To Send
9
NC
Not Connected
8
Sense Input
RJ-45 Connector Pin Out
Pin Signal
Description
1
Sense 1
}
3-24 VDC
2
Sense 2
3
IR-in (future use)
4
+12 VDC in/out
5
+12 VDC in/out
6
IR-in (future use)
7
Ground
8
Ground
Mounting
The ProLink.z can be wall mounted (details below) or free standing.
Mounting Instructions
Name Description
To mount to a wall, shelf, or cabinet use the enclosed mounting plate.
DSR
Data Set
Ready
1 For best results, install the ProLink.z at least three (3) feet away from
DCD
Carrier
Detect
cable or satellite equipment, WiFi enabled devices, TV's, and/or any other
DTR
Data Terminal
potential source of RF interference.
Ready
2 Level and anchor the mounting plate to desired wall, shelf, or cabinet by
GND
Signal Ground/
using appropriate fasteners (four #6-32 3/4" flathead screws included) to
Common
screw through the mounting plate fastener holes.
RXD
Receive Data
3 When mounting the ProLink.z, be certain to choose a safe location (e.g.
TXD
Transmit
Data
away from electrical junction boxes, circuit breakers, wet locations, etc.)
CTS
Clear To
4 Affix the ProLink.z to the mounting plate by placing the channel locks
Send
located on the rear of the unit over the channel lock clips located on the
RTS
Request To
front of the mounting plate. Slide the ProLink.z down until the channel
Send
lock clips lock into place.
Minimum RF Clearance
®
Get more control
®
5 Inches
2 Inches
Mounting Plate
Need help?
Do you have a question about the Pro Control and is the answer not in the manual?
Questions and answers