Installation - Toshiba RAS-13UKHP-E Service Manual

Split wall type
Hide thumbs Also See for RAS-13UKHP-E:
Table of Contents

Advertisement

8-3. Installation

8-3-1. Optional Installation Parts
Part
Code
Refrigerant piping
Liquid side : ∅6.35 mm
: ∅9.52 mm (RAS-07UK,
A
Gas side
: ∅12.70 mm (RAS-13UK)
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
C
Putty, PVC tapes
<Fixing bolt arrangement of outdoor unit>
RAS-07UAH-E, RAS-07UA-E, RAS-07UAX-1
97 mm
Air outlet
Fig. 8-3-1
RAS-13UAH-E, RAS-13UA-E, RAS-13UAX
Air outlet
Fig. 8-3-3
• Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
• Use ∅8 mm or ∅10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach 9 drain nipple to the bottom plate of the outdoor unit
before installing it.
Parts name
RAS-10UK)
500 mm
Air inlet
Drain outlet
600 mm
Air inlet
120 mm
Drain outlet
Q'ty
one
Each
1
one
Each
RAS-10UAH-E, RAS-10UA-E, RAS-10UAX-1
Air inlet
– 34 –
FILE NO. SVM-02001
600 mm
111 mm
Drain outlet
Air outlet
Fig. 8-3-2