Serioux SRXU-1200S User Manual

Stand by ups

Advertisement

Quick Links

Specification

Characteristic
Rated Power
Backup Power
Input
AVR Range
Output
Frequency
Type
Capacity
Battery
Back-up time (half load)
Typical Recharge Time
Status
LCD indicators
Battery Mode
Audible Alarm
Overload
Temperature
Operating Environment
Humidity
Audible Noise
Transfer time
Net weight
Dimension (WxDxH)

Maintenance

1.With normal use, a UPS battery will last three to six years depend on number of discharge and
temperature. Replacement and servicing of the battery should be performed or supervised by
personnel knowledgeable of batteries and their precautions. Keep unauthorized persons away.
2.Charge the UPS's battery every 3 months during extended storage.
3.Disconnect the power during extended storage to avoid overcharge of the battery.
4.Avoid overload or short circuit thought the UPS have build-in overload and short circuit
protect function.

Troubleshooting

Problem
Possible Cause
POWER button not pushed or
UPS not on, LCD not light
push too short.
PCB failure
Power cord lose
AC fuse burn out
UPS always at battery mode
Line voltage too high, too low
or black out
PCB failure
Buzzer continuous beeping
Overload
UPS does not provide expected
Battery is weak due to wear or
run time. Low battery warning
successive mains outages
is sounded prematurely.
Specifications are subject to change without prior notice
Specification
1200VA
720W
165V~275V
175V~265V
220V±10%
50Hz/60Hz
Sealed, maintenance-free lead acid
12V 7Ah/ 2 PCs
Over 8 Minutes
8-hour
NORMAL, FAULT, BATTERY, CHARGE, OVERLOAD
Beeping sound every four seconds, every
second if approaches final discharge
Continuous beeping sound
-5℃~40℃
10%~90% RH, non condensing.
< 45dB A
< 10 ms
12.00 Kg
120x300x190 mm
Action To Take
Press the POWER button and
hold more than 4 seconds.
Replace the PCB, call for service
Replug the power cord
Replace the AC fuse
normal condition
Replace the PCB, call for service
Remove the noncritical loads
Allow UPS to recharge battery for
a minimum of 8 hours. If UPS
sounds low battery warning
prematurely, when retested, battery
should be replaced.
,
USER S MANUAL
UPS-1200D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRXU-1200S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Serioux SRXU-1200S

  • Page 1 Specification Characteristic Specification Rated Power 1200VA 720W Backup Power Input 165V~275V AVR Range 175V~265V USER S MANUAL Output 220V±10% Frequency 50Hz/60Hz Type Sealed, maintenance-free lead acid Capacity 12V 7Ah/ 2 PCs UPS-1200D Battery Back-up time (half load) Over 8 Minutes Typical Recharge Time 8-hour Status...
  • Page 2 Introduction Presentation Front Panel Rear Panel SUP-1200D can instantly switches your computer to emergency battery backup power and allows you to work through brief power outages without data loss or downtime. It continuo usly conditions the power coming into your computer and providing power supply for virtually zero interruption.

Table of Contents