Orion OE392-10-GPCXP Technical Manual

Orion OE392-10-GPCXP Technical Manual

System manager ts ii for gpc-xp

Advertisement

System Manager TS II
For GPC-XP
Technical Guide
GPC-XP Controller Code: YS102432 Revision 4.0 and up

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OE392-10-GPCXP and is the answer not in the manual?

Questions and answers

Summary of Contents for Orion OE392-10-GPCXP

  • Page 1 System Manager TS II For GPC-XP Technical Guide GPC-XP Controller Code: YS102432 Revision 4.0 and up...
  • Page 2: Table Of Contents

    Zone TABLE OF CONTENTS Zone OVERVIEW ................................ 3 COMPONENTS AND WIRING ..........................4 Flush Wall Mount Dimensions and Components .........................5 Surface Mount Dimensions and Components ..........................6 SMTS II to GPC-XP Controller Wiring ............................7 NAVIGATION ..............................8 Main Screen Icons and Button Functions.............................8 MAIN SCREEN FUNCTIONS ..........................
  • Page 3: Overview

    OVERVIEW System Manager TS II Features System Requirements The OE392-10-GPCXP System Manager TS II (Touch Screen) for • The System Manager TS II is packaged and assembled for the GPC-XP Controller provides a direct, graphic-enhanced, menu- fl ush wall mounting. Surface mount components are also driven link to enable you to view the status, perform force modes, included for your convenience.
  • Page 4: Components And Wiring

    The System Manager TS II is connected to the local communications that can maintain a temperature range between 14°F and 158°F with loop of the Orion system via 18 AWG 2-conductor, twisted pair with less than 90% RH levels (non-condensing).
  • Page 5: Flush Wall Mount Dimensions And Components

    COMPONENTS & WIRING Flush Wall Mount Dimensions and Components Figure 3: System Manager TS II Dimensions and Components ( Flush Wall Mount) SMTS II for GPC-XP Technical Guide...
  • Page 6: Surface Mount Dimensions And Components

    COMPONENTS & WIRING Surface Mount Dimensions and Components Figure 4: System Manager TS II Dimensions and Components ( Surface Mount) SMTS II for GPC-XP Technical Guide...
  • Page 7: Smts Ii To Gpc-Xp Controller Wiring

    COMPONENTS & WIRING SMTS II to GPC-XP Controller Wiring To (24 VAC) BLACK (R) Transformer - BARE (S) To (24 VAC) WHITE (T) Transformer + BROWN (GND) RED (24 VAC) WHITE (T) BARE (S) BLACK (R) BROWN (GND) RED (24 VAC) 24 VAC Transformer 5 VA Minimum Line Voltage...
  • Page 8: Navigation

    Zone NAVIGATION Zone Main Screen Icons and Button Functions Icons and Button Functions Navigation Buttons See Table 2 for a list of Navigation buttons and their functions. System settings and screens are easily accessible by simply touch- one of the fi ve icons on the Main Screen .
  • Page 9: Main Screen Functions

    MAIN SCREEN FUNCTIONS Logging In First Things First Entering Your System Manager Passcode The fi rst thing you need to do when setting up your Touch Screen is to log in. The second thing you need to do is establish user passcodes. The third thing you need to do is set the clock.
  • Page 10: Editing Passcodes

    Zone MAIN SCREEN FUNCTIONS Zone Editing Passcodes Passcode Clearance Levels Passcode Levels 1111 Below is a list of the passcode levels, default codes, and actions that You can limit access to critical settings Level #1 Passcode can be performed at the various levels. by giving the user access only to those { Temporary Schedule Overrides } items needed to maintain comfort levels...
  • Page 11: Setting The System Clock

    MAIN SCREEN FUNCTIONS Setting the System Clock Set Time and Date Currently: 10 DATA ENTRY When you fi rst power up your System Manager TS II, you will need Set Clock Hour to change the day of the week, the time, and the month, day, and Enter the Current Hour in <<...
  • Page 12: System Manager Settings

    Zone MAIN SCREEN FUNCTIONS Zone System Manager Settings System Manager Settings System Manager Address: Enter the address of the System Manager TS II. 0 = Stand Alone Mode. 63 = Network System. 1-60 <Settings> = Multiple Managers based on the following defi nitions: Additional system settings are available under the icon.
  • Page 13: Unit Selection

    GPC-XP CONTROLLER SCREENS Unit Selection and Analog Inputs My System Unit Selection < My System> From the Main Screen touch icon. Selected Unit Screen will appear. See Figure 13. NOTE: If you have chosen the One to One Unit Connection in the System Manager Settings Screen, this screen (Figure 13) will not appear.
  • Page 14 Zone GPC-XP CONTROLLER SCREENS Zone Analog Inputs, Binary Inputs, and Relay Outputs Override Reading: To override a reading for a thermistor sensor, touch the Override Reading value fi eld. The Data Entry Screen will appear. (Figure 17) Type a value that will override the actual sensor <OK>...
  • Page 15: Schedules & Holidays

    GPC-XP CONTROLLER SCREENS Relay Output Force Modes, Analog Outputs, and Analog Force Figure 25: Analog Output Force Screen Figure 22: Relay Output Force Mode Screen Force Analog Output: From the Analog Output Detail Screen Relay Force: You can now select the radio button for the force (Figure 24), you can access the Force Screen (Figure 25 above) mode—Normal Operation, Force Relay On, or Force Relay Off.
  • Page 16: Viewing And Setting Schedules

    SCHEDULES Viewing and Setting Schedules Viewing and Setting Schedules You can view and set schedules from GPC-XP Status Screen #6. You can set up to 8 different schedules. See Figure 28 below. Figure 30: Schedule Times Screen <OK> <Esc> Touch to save the time you entered or touch to exit the...
  • Page 17: Viewing And Setting Holidays

    HOLIDAYS & SCHEDULE OVERRIDE Viewing and Setting Holidays & Schedule Override Viewing and Setting Holidays Every defi ned holiday uses the Holiday operating schedule pro- grammed in the controller’s Schedules Screen You can set holidays from Status Screen #6. See Figure 31 below. Holidays can only be programmed for the current year.
  • Page 18: Alarms

    Zone ALARMS Zone Viewing and Enabling/Disabling Alarms Viewing/Enabling/Disabling Alarms <No Alarms> To view or confi gure alarms, touch <ALARM> button on any of the . See No Alarms Status Screens Figure 34. The GPC-XP Alarm Status Screen will display. See Figure 35. NOTE: <...
  • Page 19: Appendix

    APPENDIX Troubleshooting System Manager TS II LEDs, Buttons, Diagnostics Button Dipswitches & Jumpers Under the direction of WattMaster Controls Technical Support, you may have to perform diagnostics on your System Manager TS II. Press this button to do so. LEDs and system function buttons are located behind your System Manager TS II’s cover.
  • Page 20: Military Time Conversion

    Zone APPENDIX Zone Military Time Conversion Military Time Conversion Regular Military Time Time The main difference between regular and military time is how hours 11:30 a.m. 1130 are expressed. Regular time uses numbers 1 to 12 and a.m. and p.m. 12:00 p.m.
  • Page 21: Index

    INDEX 24-Hour Military Format..20 1111..9 Date..11 LCD Display 2222..9 Described..3 Descriptions 3333..9 Buttons..8 LEDs Icons..8 Communications LED..19 Diagnostics Button..19 Operation LED..19 Power LED..19 Dimensions..5 Address..12 Screen Refresh LED..19 Dipswitch Settings..4 Alarm Button..18 Update LED..19 Down Arrow Key Function..8 Function..8 Level 0 Access..10 Alarm Settings..18 Level 1 Access..10 Analog Input Details Screen..13...
  • Page 22 Zone INDEX Zone OK Key Schedule AUTO Mode..17 Technical Support..4 Function..8 Schedule FORCED OFF..17 TERM Jumpers..19 One to One Unit Connection..12, 13 Schedule FORCED ON..17 Time Operation LED..19 Schedule Override..17 Military Time Conversion..20 OPT1 Dipswitch..19 Time and Date..11 Schedules..16 OPT4 Dipswitch..19 Setting..11 Setting..16 Troubleshooting..19...
  • Page 23 NOTES SMTS II for GPC-XP Technical Guide...
  • Page 24 Form: OR-SMTSII-GPCXP-TGD-01A Printed in the USA May 2014 All rights reserved. Copyright 2014    WattMaster Controls Inc. 8500 NW River Park Drive Parkville, MO 64152 Phone: 866-918-1100 www.orioncontrols.com Fax (816) 505-1101...