Download Print this page

ORIGO 6000 Operator's Manual

Alcohol range

Advertisement

Quick Links

for ORIGO Alcohol Range model 6000, 6100 and 6200.
WATER OR A CLASS A FIRE EXTINGUISHER WILL PUT OUT AN ALCOHOL FIRE.
SPECIAL SAFETY
SECTION
Carefully read and understand these instructions
before operating your ORIGO range. Save these
instructions and review them periodically.
Fuel Safety.
1. Use only denatured alcohol. Never use gasoline, kerosene,
methanol, propane, charcoal lighter, diesel or other flammable
substances or fuels. Uncontrollable operation and flare-ups can
result and cause serious burns or personal injury.
2. Store fuel in an approved container away from the range,
the engine or other heat source.
3. Eliminate all sources of sparks or flames in the area where
fuel is poured or stored.
4. Do not smoke while working with fuel.
5. Wipe up immediately any spilled fuel.
Filling and Lighting Safety.
1. Do not attempt to fill fuel tanks while they are still in
range. Overfilling, spillage, or hot surfaces can cause serious
burns and fires.
2. Never pour fuel through burner openings in top of range.
(Picture 1)
3. Remove fuel tanks from range by carefully following
instructions.
4. Move fuel tanks to a safe area away from all sparks, flames,
or other heat sources before filling with fuel.
5. Make sure tanks are cool enough to be held in your bare
hand before filling with fuel.
6. Fuel may burn with almost invisible flame. Make sure that
flame and heat-glow are extinguished before filling the tanks.
Flame or heat-glow can cause alcohol fire, resulting in serious
burns and personal injury.
7. Do not overfill tanks. Filling instructions must be followed
closely. Check the fuel by tilting the tank vertically (Picture5).
In this position, maximum fuel level occurs when fuel just
begins to show in the recess inside the tank opening. Alcohol
expands when heated. If the tank is overfilled, the surplus will
overflow into the stove cavity and can cause uncontrollable
burning.
8. Wipe tanks to remove any excess fuel before replacing tanks
in the range.
9. Light burners by holding a lit match or long lighter at the
tank opening through the burner opening. As soon as the
burner ignites, quickly remove hand to avoid burning your
fingers.
An ORIGO lighter is recommended.
OPERATOR'S MANUAL

SAFETY INSTRUCTIONS

WARNING!

Installation and Maintenance

Safety.
1. Place range in a well-ventilated area away from all
combustible material. Excessive draft must be avoided.
2. Do not hang or place towels, papers, curtains or other
combustibles near an installed range.
3. Keep all surfaces and interior parts free of grease, alcohol or
other flammable substances.
4. To be sure of safe function of your ORIGO stove, do not use
an oversize pot. Max. recommended pot diameter: 9"(230mm)
5. Make sure the appliance is securely in position when in
operation as well as when not in use.
General Safety.
WARNING!
BE EXTREMELY SAFETY CONSCIOUS AS WITH
ANY APPLIANCE THAT OPERATES WITH AN
OPEN FLAME. INSTRUCTIONS MUST BE
FOLLOWED CLOSELY TO AVOID SEVERE
BURNS OR CREATING A FIRE HAZARD.
1. Make sure the range is installed correctly. Installation
instructions are included with the product. Repairs must be
made by qualified service personnel. Ask your dealer to
recommend qualified personnel.
2. Wear proper clothing when operating the range. Never wear
loose fitting or hanging garments as such can catch on fire.
3. Use ORIGO potholders to clamp pots to grate on the stove if
there is any risk of motion while the stove is in use. Unsecured
pots can shift or fall resulting in dangerous spills, which can
cause serious burns. (Picture 2)
1

Advertisement

loading

Summary of Contents for ORIGO 6000

  • Page 1: Safety Instructions

    Overfilling, spillage, or hot surfaces can cause serious other flammable substances. burns and fires. 4. To be sure of safe function of your ORIGO stove, do not use 2. Never pour fuel through burner openings in top of range. an oversize pot. Max. recommended pot diameter: 9”(230mm) (Picture 1) 5.
  • Page 2 These precautions will help minimize the possibility • 6000 and 6200: Mount the range as far away from of spillage, ignition of flammable materials, and/or serious combustible materials as possible, but min. 100 mm from burns.
  • Page 3 Range will operate with less than maximum capacity of fuel. To Light the Alcohol Burner. An ORIGO lighter is recommended for lighting purposes. • Stove: Turn knob to the maximum position to open the burner. Place a long match or long butane lighter at tank opening.
  • Page 4: Technical Data

    (WxHxD) 490 x 530 x 400 mm. Depth: approx. 13 3/16” (335mm) Models 6000 and 6200 are delivered with gimbals. First Tank volumes: approx. 2,5 pints each (1,2 L) determine the best position for the pivot points. This can be...

This manual is also suitable for:

61006200