Through-the-Wall
Installation
Instructions-Optional
The case may be installed
through-the-wall
in
both existing
and new construction.
Read completely,
then follow step-by-step.
NOTE: Obtain all materials
locally for mounting
the air conditioner
through-the-wall.
[i-I IMPORTANT
Through-the-wall
installation
is not appropriate
if any of the side or top louvers in the case will
be obstructed
by the wall.
All side and top louvers in the case must project
on the outdoor side of the wall.
The room side of the case must project
into the room far enough to maximize the
balance of the unit.
The case must be installed level from side-to-
side and with a slight tilt from front to rear. Use
a level; no more than a 1/2 bubble will be the
correct case slant to the outside.
B]
@
Lintel angle is required to support bricks or
blocks above opening.
Flashing is required and should extend the
length of the opening to ensure no inside cavity
leakage occurs.
Remove the air conditioner
from the case.
For specific instruction,
refer to the Window
Installation
Instructions.
Make certain that a wall receptacle
is
available
close to the hole location or make
arrant ements to install a receptacle.
?
rc1 Place the case in the wall opening and
place wood support strips between the case
bottom and the flashing on both sides of the
bottom rail. They should be the same height as
the bottom
rail and the same length as the wall
opening.
[I-I IMPORTANT {cont.)
r_
Secure with 14 wood screws anchored at least an
inch into the wall support structure.
NOTE: Drill pilot holes, if necessary, for proper
installation. If the frame is oversized, use shims to
prevent case distortion.
ITI FINISH THE WALL OPENING
r_
Caulk all four sides on the outdoor side of the
case to prevent moisture from getting through
to the interior wall. Use of flashing (drip rail) will
further prevent water from dripping inside the
wall and down the outside of the building.
Lintel angle
Plaster line
Caulking
Trim molding (if
desired)
OUTSIDE
Air louvers (top
and sides must/
project on the_-
outdoor side of
the wall)
INSIDE
Bottom rail
J
Wood filler and
caulking (above an
below the flashinc
Flashing
(Drip rail)
Bottom
rail
Flashing
(Drip rail)
Wood
support
strips
[]
Place the air conditioner
into the case.
For specific instruction,
refer to the Window
Installation
Instructions.