Installation Instructions; Through-The-Wall; Window Installation - GE AEH18 Series Owner's Manual And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

Through-the-Wall
Installation
InstructionsmOptional
The case may be installed
through-the-wall
in both existing
and new construction.
Read completely,
then follow
step-by-step.
NOTE:
Except
for the V-support
assemblies
(included),
obtain
all materials
locally for mounting
the air conditioner
through-the-wall.
ITI IMPORTANT
Through-the-wall
installation
is not
appropriate
if any of the side or top louvers
in the case will be obstructed
by the wall.
All side and top louvers in the case must
project on the outdoor side of the wall.
The room side of the case must project
into the room far enough to maximize
the
balance of the unit.
The case must be installed level from
side-
to-side and with a slight tilt from front to
rear. Use a level; no more than a 1/2 bubble
will be the correct case slant to the outside.
Lintel angle is required to support bricks or
blocks above opening.
Flashing is required and should extend the
length of the opening to ensure no inside
cavity leakage occurs.
Remove
the air conditioner
from the case.
L/_.tJ
For specific
instruction,
refer to the Window
Installation
Instructions.
[_
Make certain that a wall receptacle
is
available
close to the hole location
or make
arrangements
to install a receptacle.
[]
Place the case in the wall opening
and place
wood support
strips
between
the case
bottom
and the flashing
on both sides of the
bottom
rail. They should
be the same height
as the bottom
rail and the same length
as
the wall opening.
15
ITI IMPORTANT
(cont.)
[_
Secure with 14 wood screws anchored
at
least an inch into the wall support
structure.
NOTE: Drill pilot holes, if necessary,
for
proper
installation.
If the frame
is oversized,
use shims
to prevent
case distortion.
Install the V-supports.
See the INSTALL
THE CASE IN THE WINDOW
section
in the
Window
Installation
Instructions.
121FINISH THE WALL OPENING
[]
Caulk all four sides on the outdoor
side of
the case to prevent
moisture
from getting
through
to the interior
wall. Use of flashing
(drip rail) will further
prevent water from
dripping
inside the wall and down the
outside
of the building.
Plaster line
Lintel angle
Trim molding
Caulking
_
(if desired)
OUTSIDE
l_
INSIDE
Air louvers
P
(top and
//_'Jlv _
•.
/ ._Y_" --
Bottom
rail
sides must
_'- I
_
/
project on the I
_
/
outdoor
side
I
_
/
°fthewal')
I
_
Wood filler and
X_. _/'/_/_
,_,./I
J_
caulking
(above/_
A
I
"IdOl
I
and below the
"
\Y, I1 Ilf/_/ll/lll
flashing)
_/_
l ] [ _I l
"
V-supports
/
_
/
Case
Bottom
Flashing
/
bottom
rail
(Drip rail)
_
Flashing
(Drip rail)
Wood support
strips
Place the air conditioner
into the case.
i-'1
For specific
instruction,
refer to the Window
Installation
Instructions.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aem18 seriesAeh25 seriesAev24Aem25 seriesAew24Aeq24

Table of Contents