Features - D.W. Fearn VT-4 Operating Instructions Manual

Vacuum tube lc equalizer
Table of Contents

Advertisement

(All controls are independent and can be used in any combination)
Low Cut at 30, 40, 100, or 400 Hz,
0 to -18 dB shelving in 2 dB steps
Low Boost at 20, 40, 60, or 140 Hz,
0 to 12 dB shelving in 2 dB steps
Mid Cut at 200, 300, 400, 500, 600,
or 700 Hz, 0 to -16 dB in 2 dB steps
High Boost at 2, 3, 4, 5, 8, 10, 12, or 16 kHz,
0 to 14 dB in 2 dB steps
High Bandwidth Q of 0.6, 0.8, 1.0, 1.4, or 1.7
High Frequency Cut at 1.7, 4, 10, or 28 kHz,
0 to -14 dB shelving in 2 dB steps
Gain adjustable from -9 to +9 dB,
referenced to +4 dBm, in 3 dB steps
Note: Throughout this manual, frequency is specified in cps (cycles per second) or kc
(kilocycles per second). These units of measurement correspond to Hz and kHz respec-
tively. Specifications subject to change without notice