iBall WBS-272MV User Manual

Wireless barcode reader with memory & vibration
Hide thumbs Also See for WBS-272MV:

Advertisement

Quick Links

Wireless Barcode Reader with Memory & Vibration
WBS-272MV

Advertisement

Table of Contents
loading

Summary of Contents for iBall WBS-272MV

  • Page 1 Wireless Barcode Reader with Memory & Vibration WBS-272MV...
  • Page 2: Table Of Contents

    Table of Contents Chapter 1 System Information 1.1 About this manual 1.2 How to set up the parameter Chapter 2 System Setup 2.1 Terminator 2.2 String Options (Prefix & Suffix) 2.3 Setup Insertion Chapter 3 BarCode parameters setting UPC-A UPC-E EAN-13 EAN-8 Code39...
  • Page 3: Chapter 1 System Information

    Chapter 1 - System Information 1.1 About this manual This User's Guide provides detailed programming instructions. Barcode scanners are factory programmed for the most common communication setting. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. 1.2 How to set up the parameter -I (1) Scan Start Configuration (2) Scan all necessary labels for parameters that meet your applications.
  • Page 4: How To Set Up The Parameter

    1.2 How to set up the parameter - II Most of time the scanner only requests one read of parameters when changing to new values. You will hear two beeps when you successfully set to the new values. But for some special parameters, multiple reads are needed to complete the configuration.
  • Page 5: Chapter 2 System Setup

    Chapter 2 - System setup Start configuration End configuration 2.1 Terminator ITEM OPTION None *CR+LF Output Characters - 6 -...
  • Page 6: String Options (Prefix & Suffix)

    2.2 String Options (Prefix & Suffix) This section describes the alterations which can be made to the format of the transmitted data string. A prefix and suffix of maximum 10 direct input may be included in front and at the end of scanned barcode. Format {Prefix} {Code ID} {Bar Code} {Suffix} How to set up a prefix?
  • Page 7: Setup Insertion

    2.3 Setup Insertion This section describes how to setup the insertion of output. NOTE : Max. 10 charters can be inserted each time  Max. Insertion group is only two.  Insertion group (01) or (02) can be used in different kinds of ...
  • Page 8 Example: To insert character “A” before the third digit(3) Make the decoded data: 12A3456789 How to set up a character you want to insert Scan Start Configuration barcode Scan “G1 Insertion character” Scan “4” and “1” from FULL ASCII Table Scan Confirm configuration barcode Scan End configuration barcode How to set up position you wish to place the character...
  • Page 9 Start configuration End configuration Confirm configuration ITEM OPTION Preamble (Default:00) Ref: Appendix Postamble (Default:00) Ref: Appendix G1 Insertion character (Default:00) Ref: Appendix G2 Insertion character (Default:00) Ref: Appendix G1 Character Position to be inserted (Default:00) Ref: Appendix G2 Character Position to be inserted (Default:00) Ref: Appendix - 10 -...
  • Page 10 Start configuration End configuration ITEM OPTION *Disable Bar Code ID Enable * Read 1 Time Accuracy Read 2 Times Positive and negative bar codes Negative bar codes *Positive bar codes Code Type Code Type UPC-A Interleaved 25 UPC-E Industrial 25 EAN-13 Matrix 25 EAN-8...
  • Page 11: Chapter 3 Barcode Parameters Setting

    Chapter 3 - BarCode parameters setting How to set up a Code ID? (1) Scan Start configuration bar code (2) Go to the ASCII Table and scan label that represent the desired characters to be inserted. (3) Scan Confirm configuration bar code (4) Scan End configuration bar code.
  • Page 12 Start configuration End configuration ITEM OPTION * Disable UPC-A Expand to EAN-13 Enable Disable Check Digit Send * Enable * Disable Truncate Leading Zero Enable Truncate Leading (Default:00) Ref: Appendix (00-0DH) Truncate Ending (Default:00) Ref: Appendix (00-0DH) Insert group selection Ref: Appendix(00—02H)...
  • Page 13 Start configuration End configuration ITEM OPTION * NONE 2 digits Supplement digits 5 digits 2 or 5digits Auto-discriminate Supplement - 14 -...
  • Page 14: Upc-E

    3.2 UPC-E Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : G) Ref: Appendix (20-7EH) - 15 -...
  • Page 15 Start configuration End configuration ITEM OPTION * Disable UPC-E Expand to UPC-A Enable Disable Check Digit Send * Enable Truncate Leading (Default:00) Ref: Appendix (00-08H) Truncate Ending (Default:00) Ref: Appendix (00-08H) Insert group selection (Default:00) Ref: Appendix (00-02H) - 16 -...
  • Page 16 Start configuration End configuration ITEM OPTION *Disable Truncate Leading Zero Enable * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement - 17 -...
  • Page 17: Ean-13

    3.3 EAN-13 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : H) Ref: Appendix (20-7EH) Disable Check Digit Send * Enable Truncate Leading (Default : 00 ) Ref: Appendix (00-0DH) Truncate Ending (Default : 00 ) Ref: Appendix (00-0DH) - 18 -...
  • Page 18 Start configuration End configuration ITEM OPTION * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement * Disable ISBN/ISSN Conversion Enable Insert group selection (Default : 00 ) Ref: Appendix (00-02H) - 19 -...
  • Page 19: Ean-8

    3.4 EAN-8 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : I) Ref: Appendix (20-7EH) Disable Check Digit Send * Enable Truncate Leading (Default : 00) Ref: Appendix (00-08H) - 20 -...
  • Page 20 Start configuration End configuration ITEM OPTION Truncate Ending (Default : 00) Ref: Appendix (00-08H) * None 2 digits Supplement digits 5 digits 2 or 5 digits Auto-discriminate Supplement Insert group selection (Default : 00) Ref: Appendix (00-02H) - 21 -...
  • Page 21: Code39

    3.5 Code39 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : J) Ref: Appendix (20-7EH) * Disable Check-sum verification Enable Disable Check-sum transmission * Enable - 22 -...
  • Page 22 Start configuration End configuration ITEM OPTION * Disable Append Enable Min. code length (Default: 00) Ref: Appendix (00-32H) Max. code length (Default: 32H) Ref: Appendix (00-32H) Format * Standard Code39 Code 39 Full ASCII - 23 -...
  • Page 23 Start configuration End configuration ITEM OPTION * Disable Transmit Start/End Character Enable Truncate Leading (Default: 00) Ref: Appendix (00-32H) Truncate Ending (Default: 00) Ref: Appendix (00-32H) Insert group selection (Default: 00) Ref: Appendix (00-02H) - 24 -...
  • Page 24: Codabar

    3.6 Codabar Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : K) Ref: Appendix (20-7EH) - 25 -...
  • Page 25 Start configuration End configuration ITEM OPTION Disable Check-sum verification * Enable * Disable Check-sum transmission Enable * Disable Append Enable Truncate Leading (Default:00) Ref: Appendix (00-7EH) - 26 -...
  • Page 26 Start configuration End configuration ITEM OPTION Truncate Ending (Default:00) Ref: Appendix (00-7EH) * ABCD/ABCD Start/End type abcd/abcd abcd/tn*e * Disable Start/End transmission Enable Min. code length (Default: 05) Ref: Appendix (00-3CH) - 27 -...
  • Page 27 Start configuration End configuration ITEM OPTION Max. code length (Default: 3CH) Ref: Appendix (00-3CH) Insert group selection (Default: 00) Ref: Appendix (00-02H) - 28 -...
  • Page 28: Code93

    Code93 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : L) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable - 29 -...
  • Page 29 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable Min. code length (Default: 00) Ref: Appendix (0-50H) Max. code length (Default: 50H) Ref: Appendix (0-50H) Truncate Leading (Default: 00) Ref: Appendix (00-7EH) Truncate Ending (Default: 00) Ref: Appendix (00-7EH) Insert group selection Ref: Appendix (00-02H) - 30 -...
  • Page 30: Code128

    3.8 Code 128 Start configuration End configuration ITEM OPTION Disable Read * Enable Code ID setting (Default : M) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable - 31 -...
  • Page 31 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable * Disable FNC2 Append Enable * Disable UCC/EAN128 Enable * Disable FNC1 transmission Enable - 32 -...
  • Page 32 Start configuration End configuration ITEM OPTION FIELD SEPARATOR DEFINED (GS CHARACTER) Enable Field Separator Ref: Appendix Truncate Leading (Default: 00) Ref: Appendix (00-7FH) Truncate Ending (Default: 00) Ref: Appendix (00-7FH) Min. code length (Default: 00) Ref: Appendix (00-7FH) Max. code length (Default: 7FH) Ref: Appendix (00-7FH) Insert group selection...
  • Page 33: Interleaved2 Of

    Interleaved 2 of 5 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : N) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable Disable Check-sum transmission * Enable - 34 -...
  • Page 34 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-7EH) Truncate Ending (Default : 00) Ref: Appendix (00-7EH) Min. code length (Default : 04) Ref: Appendix (04-7FH) Max. code length (Default : 7FH) Ref: Appendix (00-7FH) Insert group selection (Default : 00) Ref: Appendix (00-02H)
  • Page 35: Industrial 2Of

    3.10 Industrial 2 of 5 Start configuration End configuration ITEM OPTICON * Disable Read Enable Code ID setting (Default : O) Ref: Appendix (20-7EH) Min. code length (Default : 00) Ref: Appendix (00-32H) Max. code length (Default : 32H) Ref: Appendix (00-32H) - 36 -...
  • Page 36 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-32H) Truncate Ending (Default : 00) Ref: Appendix (00-32H) * Disable Check-sum verification Enable Disable Check-sum transmission * Enable Insert group selection (Default : 00) Ref: Appendix (00-02H) - 37 -...
  • Page 37: Matrix 2 Of

    3.11 Matrix 2 of 5 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : P) Ref: Appendix (20-7EH) * Disable Check-sum verification Enable - 38 -...
  • Page 38 Start configuration End configuration ITEM OPTION Disable Check-sum transmission * Enable Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min. code length (Default : 0B) Ref: Appendix (00-50H) Max. code length (Default : 50H) Ref: Appendix (00-50H) Insert group selection (Default : 00)
  • Page 39 3.12 CHINA POSTAL CODE Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : Q) Ref: Appendix (20-7EH) * Disable Check-sum verification Enable Disable Check-sum transmission * Enable - 40 -...
  • Page 40 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min.code length (Default : 00) Ref: Appendix (00-50H) Max.code length (Default : 50H) Ref: Appendix (00-50H) Insert group selection (Default : 00) Ref: Appendix (00-02H) - 41 -...
  • Page 41: Msi/Plessey

    3.13 MSI/Plessey Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default : R) Ref: Appendix (20-7EH) * Disable MOD 10 Check-sum verification MOD 10/10 MOD 11/10 - 42 -...
  • Page 42 Start configuration End configuration ITEM OPTION Disable Check-sum transmission * Enable Truncate Leading (Default : 00) Ref: Appendix (00-3CH) Truncate Ending (Default : 00) Ref: Appendix (00-3CH) Min. code length (Default : 00) Ref: Appendix (00-3CH) Max. code length (Default : 3CH) Ref: Appendix (00-3CH) Insert group selection (Default : 00)
  • Page 43: Code 32

    3.14 CODE 32 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID Setting (Default:S) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable Disable Check-sum transmission * Enable - 44 -...
  • Page 44 Start configuration End configuration ITEM OPTION Truncate Leading (Default : 00) Ref: Appendix (00-0AH) Truncate Ending (Default : 00) Ref: Appendix (00-0AH) Insert group selection (Default : 00) Ref: Appendix (00-02H) - 45 -...
  • Page 45: Code 11

    3.15 CODE 11 Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default:T) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable - 46 -...
  • Page 46 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable Truncate Leading (Default : 00) Ref: Appendix (00-50H) Truncate Ending (Default : 00) Ref: Appendix (00-50H) Min. code length (Default : 00) Ref: Appendix (00-50H) Max. code length (Default : 50H) Ref: Appendix (00-50H) Insert group selection (Default : 00)
  • Page 47: Telepen

    3.16 Telepen Start configuration End configuration ITEM OPTION * Disable Read Enable Code ID setting (Default:V) Ref: Appendix (20-7EH) Disable Check-sum verification * Enable Only Numnic Data Format *Full ASCII - 48 -...
  • Page 48 Start configuration End configuration ITEM OPTION * Disable Check-sum transmission Enable Truncate Leading (Default : 00) Ref: Appendix (00-40H) Truncate Ending (Default : 00) Ref: Appendix (00-40H) Min. code length (Default : 00) Ref: Appendix (00-40H) Max. code length (Default : 40H) Ref: Appendix (00-40H) Insert group selection (Default : 00)
  • Page 49: Gs1 Databar

    3.17 GS1 Data Bar (RSS) Start configuration End configuration ITEM OPTION Enable RSS-14 *Disable Enable RSS-14 LIMITED *Disable Enable RSS-14 EXPANDED *Disable Enable RSS TO UPC/EAN *Disable - 50 -...
  • Page 50 Start configuration End configuration ITEM OPTION *Enable APPLICATION ID TRANSMISSION Disable *Enable CHECKSUM TRANSMISSION Disable - 51 -...
  • Page 51: Appendix

    Appendix A – - 52 -...
  • Page 52 KBD Wedge Character Table Type Type 2 Type Type Insert Delete “ Home Down & Left ‘ Backspace Right PageUp < Enter PageDown > Right ALT Enter key on Num keypad Note 1:If scan the following barcode the output data pleaser refer to type 1 (in blue) Type 1 Note 2:...
  • Page 53 Char. Char. “ & ‘ < > - 54 -...
  • Page 54 Char. Char. ‘ - 55 -...
  • Page 55 Table-Hex HEXADCIMAL Confirm configuration End Configuration - 56 -...
  • Page 56 * Product specifications are subject to change without notice. * All trademarks, logos, brands & product names are properties of their respective owners. * Warranty: All iBall products are governed by iBall Warranty terms. Refer www.iball.co.in for details. • For any technical help on iBall products, please contact support@iball.co.in...

Table of Contents