Kozy-World KWN217 Owner's Operation And Installation Manual

Kozy-World KWN217 Owner's Operation And Installation Manual

Blue flame vent-free natural gas space heater

Advertisement

Kozy-World
OWNER ' S OPERATION AND INSTALLATION MANUAL
KWN215
KWN315

Table of Contents

Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air..............................4
Installation................................................................6
Operating Your Heater............................................10
Cleaning & Maintenance.......................................13
Trouble Shooting...................................................14
Specifications..........................................................17
Parts List..................................................................19
World Marketing of America, Inc.
P.O. Box 192, Rt. 22 West
Mill Creek, PA 17060
KOZY WORLD PHONE NUMBER: (814) 643-1775
http://www.worldmkting.com
R
KWN217
KWN317
Save this manual for future reference.
BLUE FLAME VENT-FREE
NATURAL GAS SPACE
WARNING: If the information in this
manual is not followed exactly, a f i r e o r
e x p l o s i o n
m a y
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) f r o m t h e r o o m
i n
w h i c h
i t
i s installed. Provisions for
adequate combustion and ventilation air must
b e p r o v i d e d . R e f e r t o A i r F o r Combus-
tion and Ventilation section on page 4 of this
manual.
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l
Do not try to light any appliance.
l
Do not touch any electrical switch; do not
use any phone in your building.
l
Immediately
call
neighbor's phone. Follow the gas supplier's
instructions.
l
If you
cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
q u a l i f i e d
i n s t a l l e r , s e r v i c e
supplier.
WA R N I N G :
adjustment, alteration, service or mainte-
nance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket*
permanently
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
HEATER
r e s u l t causing property
your gas supplier from a
a g e n c y
I m p r o p e r
i n s t a l l a t i o n ,
located, manufactured
o r
g a s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KWN217 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kozy-World KWN217

  • Page 1: Table Of Contents

    . R e f e r t o A i r F o r Combus- tion and Ventilation section on page 4 of this manual. KWN217 KWN215 Do not store, or use gasoline or other flammable...
  • Page 2: Important Safety Information

    IMPORTANT Keep the appliance area clear Turn heater off before using SAFETY INFORMATION a n d f r e e f r o m c o m b u s t i b l e furniture polish, wax, carpet materials, gasoline, and other WARNINGS cleaner, or similar products.
  • Page 3: Product Features

    PRODUCT FEATURES Figure1-Vent-Free Natural Gas Heater SAFETY DEVICE LOCAL CODES Th i s h e a t e r h a s a p i l o t w i t h O x y ge n Install and use heater with care. Follow all local Depletion Sensor(ODS) safety shutoff system.
  • Page 4: Proper Ventilation & Fresh Air

    Unusually Tight Construction Confined and FRESH AIR FOR The air that leaks around doors and Unconfined Space COMBUSTION AND windows may provide enough fresh The National Fuel Gas Code ANS VENTILATION air for combustion and ventilation. Z223.1 defines a confined space However, in buildings of unusually as a space whose volume is less...
  • Page 5 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 40,000 Btu/Hr Gas furnace Btu/Hr Vent free heater 20,000 Btu/Hr Vented gas heater Btu/Hr Total 60,000 Btu/Hr Gas Fireplace logs Btu/Hr Other gas appliances* +...
  • Page 6: Installation

    VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts: You must provide two permanent openings: one " within 12 of the ceiling and one within " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 7 Attaching to wall stud Attaching to wall anchor Attaching To Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracketand Model KWN215 KWN217 Figure 5 - Moving Thermostat into wall studs. Sensing Bulb Figure 8 - Mounting Bracket Clearances...
  • Page 8 INSTALLATION Attaching Mounting Bracket to IMPORTANT: Do not Wall hammer key! For thick walls Note: Wall anchors, mounting " (over 1/2 thick) or solid walls, screws, and spacers are in do not pop open wings. hardware package. The hardware package is provided with heater.
  • Page 9 INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance " requires a 3/8 NPT (National Pipe Thread) inlet connection to the pressure regulator. WARNING: Never connect heater to private (non-utility) gas well.
  • Page 10: Operating Your Heater

    INSTALLATION CHECKING GAS OPERATING YOUR HEATER Pressure Testing Heater Gas THERMOSTAT MODELS CONNECTIONS Connections FOR YOUR SAFETY WARNING: Test all gas 1. Open equipment shutoff valve READ BEFORE LIGHTING piping and connections for leaks after (see Figure 14). installing or servicing. Correct all 2.
  • Page 11 OPERATING YOUR HEATER THERMOSTAT MODELS 7. Keep control knob pressed in This increases or decreases LIGHTING for thirty (30) seconds after burner flame height. At times the room INSTRUCTIONS lighting pilot. After may exceed the set temperature. If so, 1 . S T O P ! R e a d t h e s a f e t y...
  • Page 12 OPERATING YOUR HEATER NON-THERMOSTAT MODELS LIGHTING With control knob pressed in, push down and release the INSTRUCTIONS ignitor button. This will light FOR YOUR SAFETY STOP! Read safety pilot. if needed, keep pressing READ BEFORE LIGHTING information, on the side of ignitor button until pilot lights.
  • Page 13: Cleaning & Maintenance

    INSPECTING BURNER CLEANING ODS/PILOT AND WARNING: If yellow tipping Check pilot flame pattern and BURNER o c c u r s , y o u r h e a t e r c o u l d Use a vacuum cleaner,pressur- burner flame pattern often.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Note : troubleshooting CAUTION: Never use a wire, WARNING: Only a qualified items are listed in order of service person should service and needle, or similar object to clean operation. repair heater. ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in,...
  • Page 15: Troubleshooting

    TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning Bu r ner (s )d o es not l ight after and Maintenance , Page 13) or ODS/pilot is lit. replace burner orifice. 2.
  • Page 16 TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 17: Specifications

    SPECIFICATIONS KWN215 KWN217 KWN315 KWN317 Btu(available) 10,500/20,000 9,000/20,000 15,000/30,000 14,000/30,000 Gas Type Natural Only Natural Only Natural Only Natural Only Ignition Piezo Piezo Piezo Piezo " " " " Pressure Regulator setting W.C. W.C. W.C. W.C. Inlet Gas Pressure *(inches of water) "...
  • Page 18 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS KWN217 KWN317 ODS/Pilot Assembly...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replace- KWN217 ment parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KWN317 KWN317 KWN217 PART NO. DESCRIPTION PART NO. Cabinet Assembly MB10002...
  • Page 20 ILLUSTRATED PARTS BREAKDOWN NON-THERMOSTAT MODELS KWN215 KWN315 ODS/Pllot Assembly...
  • Page 21 PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, KWN215 follow the instructions listed under Replacement Parts on page17 of this manual. KWN315 KWN215 KWN315 PART NO. DESCRIPTION PART NO. Cabinet Assembly MB10005 MB10003 Lower Front Panel Assembly MB09002 MB09001 Reflector Unit...