Setting The Test Mode; Exiting The Test Mode; Basic Operations Of The Test Mode; Selecting The Test Mode - Sony MDS-B6P Service Manual

Md player
Hide thumbs Also See for MDS-B6P:
Table of Contents

Advertisement

3-1. Setting the Test Mode

While pressing the AMS knob, turn POWER switch on, and release the AMS knob.

3-2. Exiting the Test Mode

Turn POWER switch off.

3-3. Basic Operations of the Test Mode

All operations are performed using the AMS knob, ENTER/YES button, and EDIT/NO button.
The functions of these buttons are as follows.
Function
Changes parameters and modes
AMS knob
Proceeds onto the next step. Finalizes input.
ENTER/YES button
Returns to previous step. Stops operations.
EDIT/NO button

3-4. Selecting the Test Mode

Twelve test modes are selected by turning the AMS knob.
Display
TEMP ADJUST
Temperature compensation offset adjustment
LDPWR ADJUST
Laser power adjustment
EFBAL ADJUST
Traverse adjustment
FBIAS ADJUST
Focus bias adjustment
FBIAS CHECK
Focus bias check
CPLAY MODE
Continuous playback mode
For detailed description of each adjustment mode, refer to 4. Electrical Adjustments.
If a different adjustment mode has been selected by mistake, press the EDIT/NO button to exit from it.
* The EP MODE, RS232C CHECK and PARA-RMT CHK is not used in servicing. If set accidentally, press the EDIT/NO button immediately
to exit it.
3-4-1. Operating the Continuous Playback Mode
1. Entering the continuous playback mode
1 Set the disc in the unit (Whichever recordable discs or discs for playback only are available.)
2 Rotate the AMS knob and display "CPLAY MODE".
3 Press the ENTER/YES button to change the display to "CPLAYIN".
4 When access completes, the display changes to "C1 =
Note : The " " displayed are arbitrary numbers.
2. Changing the parts to be played back
1 Press the ENTER/YES button during continuous playback to change the display to "CPLY MID", "CPLAY OUT".
When pressed another time, the parts to be played back can be changed.
2 When access completes, the display changes to "C1 =
Note : The " " displayed are arbitrary numbers.
3. Ending the continuous playback mode
1 Press the EDIT/NO button. The display will change to "CPLY MODE".
2 Press the EJECT button and remove the disc.
Note 1 : The playback start addresses for IN, MID, and OUT are as follows.
IN
40h cluster
MID
300h cluster
OUT
700h cluster
3-4-2. Non-Volatile Memory Mode
This mode reads and writes the contents of the non-volatile memory.
It is not used in servicing. If set accidentally, press the EDIT/NO button immediately to exit it.
SECTION 3
TEST MODE
Contents
Contents
AD =
AD =
— 32 —
Display
EP MODE
Non-volatile memory mode *
VERSION DISP
Micro computer soft version
RS232C CHECK
RS232C check *
PARA-RMT CHK
Parari mode check *
HOURS MT DISP
Hours meter operating mode
SETUP INIT
Setup initialize mode
".
".
Contents

Advertisement

Table of Contents
loading