Haier HSU-26HEK03/R2DB Installation Manual

Room air conditioner

Advertisement

Quick Links

Installation manual

for room air conditioner
HSU-26HEK03/R2(DB)/I
HSU-35HEK03/R2(DB)/I
HSU-53HEK03/R2(DB)/I
HSU-71HEK03/R2(DB)/I
HSU-26HEK03/R2(DB)/O
HSU-35HEK03/R2(DB)/O
HSU-53HEK03/R2(DB)/O
HSU-71HEK03/R2(DB)/O
Read this manual before installation and keep it for future reference.
Please explain to the user how the product works and refer them to the operation manual.
NO.0010553937

Advertisement

loading

Summary of Contents for Haier HSU-26HEK03/R2DB

  • Page 1: Installation Manual

    Installation manual for room air conditioner HSU-26HEK03/R2(DB)/I HSU-35HEK03/R2(DB)/I HSU-53HEK03/R2(DB)/I HSU-71HEK03/R2(DB)/I HSU-26HEK03/R2(DB)/O HSU-35HEK03/R2(DB)/O HSU-53HEK03/R2(DB)/O HSU-71HEK03/R2(DB)/O Read this manual before installation and keep it for future reference. Please explain to the user how the product works and refer them to the operation manual. NO.0010553937...
  • Page 2 Content Preparation Accessory parts Selection pipe Drawing for the installation of indoor and outdoor units Indoor unit Outdoor unit Refrigerant charge label Check for installation and test run...
  • Page 3 Preparation Accessory parts Remote controller (1) Drain hose (1) Necessary tools for installation AAA dry battery (2) Cushion (4) Driver Nibbler Mounting plate (1) Drain-elbow (1) Hacksaw Plastic cap (4) Pipe supporting plate (1) Hole core drill Ø4X25 Screw (4) Spanner (17,19 and 26mm) Gas leakage detector or soap-and-water solution Vacuum pump...
  • Page 4 Drawing for the installation of indoor and outdoor units Attention must be Optional parts for piping paid to the rising up More than 5cm (26/35/53) of drain hose More than 10cm (71) Non-adhesive tape Adhesive tape Saddle (L.S.) with screws Connecting electric cable for indoor and outdoor Drain hose...
  • Page 5 Indoor Unit Fitting of the Mounting Plate and Positioning of the Wall Hole Making a Hole on the Wall and Fitting the Piping Hole Cover Make a hole of ‘B’mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation. 1.
  • Page 6 Indoor unit cont. DRED Function Connecting the indoor/outdoor Electric Cable 6.Please consult your reseller and/or installer to determine if you have a DRED appliance. Connect output from your home's electricity power meter (where available) to the RJ45 connector on the outdoor unit, as shown. Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, (This function is unavailable on some models.)
  • Page 7 Outdoor unit cont. Connection of Electrical Cable Step 4 Open the 2-way valve to an angle of anticlockwise 90 degrees. Use the same method on indoor unit. Loosen the screws on terminal block After 6 seconds, close the 2-way valve and test for refrigerant gas leakage. and insert the plugs fully into terminal block, then tighten the screws.
  • Page 8 Outdoor unit cont. Refrigerant charge label Contains fluorinated greenhouse gases covered by the Kyoto Protocol Power Source Installation R410A The air conditioner must be wired with a dedicated circuit to the distribution board. The protection device should be sized to meet the current requirements of the unit as shown on page 3 and comply with local and national wiring standards.