Advertisement

Distribution France
Distribution UK
Ypsomed S.A.S
Ypsomed Ltd
18/20 Rue Soleillet
Blackwood Hall Business Park
FR-75020 Paris
North Duffield
Tél.: +33 (0)015870 2000
Selby, North Yorkshire
Fax: +33 (0)015870 2001
YO8 5DD
Numéro gratuit: 0800 883058
Customer Care: +44 844 856 7820
info@ypsomed.fr
Fax:
www.mylife-diabetescare.fr
Email: info@ypsomed.co.uk
www.mylife-diabetescare.co.uk
BIONIME CORPORATION
Bionime GmbH
No. 100, Sec. 2, Daqing St.,
Tramstrasse 16,
South Dist., Taichung City 40242,
CH-9442 Berneck / Switzerland
Taiwan
E-mail: info@bionime.ch
+44 844 5070 443
Manufactured for
Ypsomed Distribution AG
CH-3401 Burgdorf
Switzerland
0197
Système de mesure de la glycémie
Blood glucose monitoring system
Manuel de l'utilisateur
User manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pura and is the answer not in the manual?

Questions and answers

Carol Eke
March 16, 2025

How do I get a code for my Pura

1 comments:
Mr. Anderson
March 16, 2025

The mylife Pura blood glucose meter uses autocoding technology, so you do not need to enter a code to test your blood glucose.

This answer is automatically generated

Andrew
January 31, 2025

Machine displaying ERROR with no number

1 comments:
Mr. Anderson
May 14, 2025

When the mylife Pura machine displays an ERROR with no number, it likely means that the blood drop was applied to the test strip before the meter displayed the test symbol. This can also occur if the ambient temperature is outside the correct testing range of 10–40°C (50–104°F).

This answer is automatically generated

Carol Eke
March 16, 2025

I do not give card details on phone

Carol Eke
March 16, 2025

I do not give bank details on phone

Subscribe to Our Youtube Channel

Summary of Contents for mylife Pura

  • Page 1 Fax: +33 (0)015870 2001 YO8 5DD Numéro gratuit: 0800 883058 Customer Care: +44 844 856 7820 info@ypsomed.fr Fax: +44 844 5070 443 www.mylife-diabetescare.fr Email: info@ypsomed.co.uk www.mylife-diabetescare.co.uk BIONIME CORPORATION Bionime GmbH Manufactured for No. 100, Sec. 2, Daqing St., Tramstrasse 16, Ypsomed Distribution AG South Dist., Taichung City 40242,...
  • Page 2: Intended Use

    The mylife Pura blood glucose monitoring system is intended in vitro (outside the body) manual thoroughly before testing. It provides all information you need to use the product. The mylife diagnostic use for self testing. Coding is automatically detected. The test result is achieved using fresh capillary whole blood samples from the fingertip, palm or forearm.
  • Page 3: Table Of Contents

    Meter data transmission management (optional) Customer service Description of used symbols Testing procedure Warranty Performing a blood glucose test with mylife Pura BGMS Disposing of the mylife Pura meter, test strips and lancets Alternative site testing (AST) View window appearance Main parts...
  • Page 4: Tm Tm Bgms

    (with 2 CR2032 batteries installed) mylife Pura test strips (10 pcs) mylife Pura getting started guide mylife Pura BGMS user manual mylife Pura blood glucose test strip insert mylife Softlance lancing device mylife Pura clear adjustable cap ("AST") 8. Disposable...
  • Page 5: Tm Tm Meter

    Pura meter mylife Pura meter Test strip port Insert test strip here until you hear a click. Battery cover Slide cover to change Display window batteries. Shows test result, messages and Meter battery relevant information. Product name Main button (...
  • Page 6 Pura meter mylife Pura meter Indicates a test result stored in meter memory Indicates when to apply the blood sample (memory mode) Indicates a test result which is not included in Test strip (internal calibration and autocoding) average function of this meter...
  • Page 7: Precautions For Mylife Pura Bgms

    4.0 µL - The meter must only be used with mylife Pura test strips and mylife Control / Pura control Sample size example solution. The use of other test strips or control solutions may lead to incorrect results. BGMS has not been validated for use on neonates.
  • Page 8: Tm Tm

    Pura test strip The meter must only be used with mylife Pura test strips and mylife Control / Pura control solution. The use of other test strips or control solutions may lead to incorrect results. Electrode contacts Sensing signal output terminals.
  • Page 9: Meter Activation And Battery Change

    Meter activation and battery change Meter activation and battery change Your meter comes with two CR2032, 3 volt, batteries installed. Two new batteries will provide power to perform about 1,000 tests under normal use. Press the main button or insert a test strip to activate your meter.
  • Page 10: Setting Up Your Meter - Setting The Date, Time And Volume

    Setting up your meter – Setting the date, time and volume Setting up your meter – Setting the date, time and volume You can enter setting mode in two ways: 1. Year setting 1. Reload meter battery With the year format flashing , press the left or right button to adjust it.
  • Page 11 Setting up your meter – Setting the date, time and volume Setting up your meter – Setting the date, time and volume 4. Time format 12/24h selection Finishing setting up With the time format flashing , press the left or right button After volume settings, you will hear a confirmation beep (if volume is...
  • Page 12: Switching The Mylife Pura Meter On/Off

    Switching the mylife Pura meter on/off Switching the backlight on/off 1. How to switch on the meter 1. How to switch on the backlight Press the main button or insert a test strip. Press the main button for 2 seconds after power is on.
  • Page 13: Performing A Blood Glucose Test With Mylife Pura Bgms

    Performing a blood glucose test with mylife Pura BGMS Performing a blood glucose test with mylife Pura BGMS 6. Choose penetration depth by rotating the top portion of the depth-adjustable Depth-adjustable cap Release button cap until the required setting depth is indicated in the window.
  • Page 14 Performing a blood glucose test with mylife Pura BGMS Performing a blood glucose test with mylife Pura BGMS 11. A blood drop symbol appears and is accompanied by a 15. Pull off the depth-adjustable cap of the lancing device. further beep (if volume is switched on).
  • Page 15: Alternative Site Testing (Ast)

    Alternative site testing (AST) Alternative site testing (AST) Alternative site testing: Palm or forearm blood sampling PRECAUTION - The blood glucose test results of blood samples taken from different sites might vary Select clear cap ("AST") and follow steps 1 to 11 on pages certain conditions,...
  • Page 16: View Window Appearance

    View window appearance "Lo" and "Hi" readings of mylife Pura meter Make sure your blood sample covers the eter displays results between 10 and 600 mg/dL. If your test result is below 10 whole area of the view window to get an mg/dL , "Lo"...
  • Page 17 Quality control test with mylife Control control solution Quality control test with mylife Control control solution When should a quality control test be performed? Possible reasons your control solution results are out of range: - our control solution has expired or has been opened for more than 3 months.
  • Page 18: Performing A Quality Control Test

    Performing a quality control test Performing a quality control test 1. Take one test strip from vial and recap immediately. Clean the top of the cap and tightly replace the cap on the control solution CLOSE bottle. 2. Insert the test strip with indication symbol upfront and down into test 10.
  • Page 19: Recalling Test Results And Averages

    Performing a quality control test Recalling test results and averages Maintenance eter is able to store 500 test results with time and date automatically. If your meter has stored Keep your meter and test strip free of dust, water or any other liquid. Store the meter in the carrying 500 results, which is the maximum memory, the newest test result will replace the oldest one.
  • Page 20 Recalling test results and averages Recalling test results and averages enable averages to show. For example, the 14-day average will show no figure if there have been no tests recorded in the 14 days prior to, and including, the current date. - The non-averaging/re-averaging function only works in the test mode and when you "...
  • Page 21: Error Messages And Trouble Shooting

    Error messages and trouble shooting Error messages and trouble shooting Er1 - The inserted test strip has been used or is damaged . Please use Battery error a new test strip from vial. 1. The " " symbol flashes when battery power is low. Change meter battery as soon as...
  • Page 22 Error messages and trouble shooting Error messages and trouble shooting Temperature error Sampling error In order to ensure accurate test results, perform testing between 10~40 °C (50~104 ). °F Please do not present the blood drop to the sample entry of the test strip before the meter displays "...
  • Page 23: Specification Of Mylife Pura Meter

    Specification of mylife Pura meter Specification of mylife Pura meter Measurement technology 30-60% Oxidase electrochemical sensor Hematocrit Measurement calibration Plasma Power supply 2 CR2032 batteries Sample Capillary whole blood Meter battery life About 1,000 tests Minimum sample volume microliter 90.6 mm x 46.0 mm x 16.5...
  • Page 24: Limitations Of Mylife Pura Meter

    BGMS is not intended for serum or plasma testing (for capillary whole blood testing only). The meter data can be managed by the mylife Pura PC-Link system. The mylife Pura PC-Link - Inaccurate test results may be obtained at altitude of more than about 3,048 meters (10,000 feet).
  • Page 25: Customer Service

    Please complete and return the enclosed warranty card to your local Ypsomed affiliate. 18/20 Rue Soleillet Blackwood Hall Business Park This warranty does not apply for any damage caused by the use of other test strips than mylife FR-75020 Paris North Duffield Pura test strips.
  • Page 26: Main Parts

    Main parts mylife Pura meter, mylife Pura test strip, mylife Control control solution Manufacturer: BIONIME CORPORATION No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan The products comply with In vitro Diagnostic Directive 98/79/EC (CE0197). EU Representative...

Table of Contents

Save PDF