Advertisement

UCT200 shown
with Designer Series Faucet
QueStIonS/CommentS? 1-800-842-4605
System Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste
NSF
and Odor, and nominal Particulate Class I and NSF/ANSI Standard 53 for the reduction of Cysts, Lead, VOC and MTBE.
®
I nStaL LatI On, U SE & C a rE GUIDE
UnDEr-SInK
Important
9am - 5pm Central Time
FILtEr SyStEMS
MODELS: UCT200
This System may require the
services of a licensed plumber.
read and Save these Instructions
®
UCT100
R 11.01 1-404-0102

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UCT200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bestfilters UCT200

  • Page 1 ® I nStaL LatI On, U SE & C a rE GUIDE UnDEr-SInK FILtEr SyStEMS MODELS: UCT200 UCT100 This System may require the services of a licensed plumber. Important read and Save these Instructions UCT200 shown with Designer Series Faucet...
  • Page 2: Table Of Contents

    Lid and Housing Assembly (ships pre-installed (includes Clamp and Base) in housing assembly) MODELS WIth DESIGnEr SErIES FaUCEt MODELS WIth VaLUE FaUCEt FILtEr LIFE InDICatOr (UCT200 models) FILtEr LIFE InDICatOr (UCT200 models) Beauty Ring (UCT100 models) Beauty Ring and Washer...
  • Page 3: Introduction

    When the rated capacity of the Cartridge has been reached When you notice a taste or odor re-occurrence When the Filter Life Indicator (FLI) begins blinking Red (UCT200 models only). 3. Read this manual completely before attempting to install or use this product.
  • Page 4: Product Specifications

    (includes Battery) (UCT200 only) 3-212-0015 3/8” T Valve 4-600-0017 Blue Tubing (5 ft.) 4-600-0015 Red Tubing (5 ft.) 9-904-0100 Spacer & Wing Nut REPUCT200 Replacement Cartridge REPUCT200 (includes Battery Shuttle and Battery) (UCT200 only) REPUCT100 Replacement Cartridge REPUCT100 (UCT100 only)
  • Page 5: Faucet Kits

    If you’d like to add an electronic Filter Life Indicator to your UCT100 System, a Faucet Kit with Filter Life Indicator will convert it to a UCT200 System! DESIGnEr SErIES FaUCEt KItS (with Filter Life Indicator)
  • Page 6: Setup And Installation

    SEt UP & InStaL LatIOn 1. Open the shipping carton, remove all System parts and place them on your kitchen counter. 2. Compare them with the parts shown in this guide to be certain all items were included (see inside front cover). 3.
  • Page 7 SEt UP & InStaL LatIOn Drilling a Hole in a porcelain/Ceramic Sink: note If your sink has another hole that currently has a spray attachment, you may decide to remove the spray attachment and use the existing hole to continue your installation (skip the next section and go to “Faucet Installation”...
  • Page 8 SEt UP & I nStaL LatIO n Drilling a hole in a Stainless Steel Sink: note If your sink has another hole that currently has a spray attachment, you may decide to remove the spray attachment, and use the existing hole to continue your installation (skip the next section and go to “Faucet Installation”) .
  • Page 9: Faucet Installation

    SEt UP & InStaL LatIOn Faucet Installation: UCt200 MODELS (Faucets WIth Filter Life Indicator) System Faucet 1. Slide the LED Beauty Ring up Faucet Tubing and onto Faucet Stem. Next, insert Cable through hole in sink, followed by Faucet LED Beauty Ring Tubing and Faucet Stem.
  • Page 10 Outlet Connector located on top of Lid Assembly. (fig . O) (Skip to instruction number 8.) UCt200 MODELS (with Filter Life Indicator): Locate an area on cabinet wall to mount the Filter Life Monitor. Secure Filter Life Monitor to the wall using the Velcro Adhesive Strips provided.
  • Page 11: Replacing The Cartridge

    The most important part of maintaining your Bestfilters ® in UCT200 models) on a regular service interval. To insure your System continues to perform as stated in the Performance Data Sheet, the Cartridge should be replaced upon the first occurrence of the following:...
  • Page 12 Gloves Do not use abrasive pads or other abrasive materials to clean System . Replacement Cartridge 5. Remove plastic sanitary wrap from new, Bestfilters ® Replacement Cartridge. Thread the new Cartridge clockwise onto the Threaded Post inside Lid Assembly until you feel resistance.
  • Page 13: Replacing The Battery Shuttle

    Red Lamp begins blinking, it is time to replace quality conditions in your area. the used Cartridge and Battery Shuttle. note: For UCT200 models, the Battery and Battery note: REPUCT200 Replacement Cartridges include new Shuttle must also be replaced at time of Cartridge Battery and Battery Shuttle replacement.
  • Page 14 OBtaIn Warranty SErVICE Call us at: 1.800.842.4605, or email us at info @ bestfilters.com for a Return Authorization Number and instructions for shipment. Products returned without a return authorization number will be refused .

This manual is also suitable for:

Uct100