Introduction
The MAC 500 is a mobile air conditioner based on the established ''split system'' air conditioning unit.
The machine is supplied in 2 sections, the Cooling Console (room unit) plus a Dry Cooler (outdoor
section) with attached flexible lines.
MAC 500 Unit
Locating the MAC 500
The MAC 500 indoor unit should be positioned in the room that requires air conditioning. It should be sited so that the air can
circulate freely with no obstructions around the discharge air grille and/or the return grille. It must be positioned in an area
where it is accessible to place the condensing unit outside taking into consideration the length of the flexible lines. When
connecting or disconnecting the lines there may be a small amount of water spillage. To prevent this from happening, use either
a cloth or a small container under the connections to catch the excess water.
The outdoor unit must be connected to the indoor unit using the flexible lines provided. The unit must be positioned outside of
the air conditioned room, and requires a free supply of air. Do not obstruct the air flow over its heat exchanger, and do not locate
the unit in a confined space or area where the heat produced will cause the temperature to rise above 35°C. Usually the outdoor
unit is better located outside the building.
Do not locate the outdoor unit more than 5 metres above the indoor unit. The outdoor unit can be stood on any level, firm
service.
While the unit is cooling, it will produce condensate (water) in the indoor unit. This will automatically be pumped through the
flexible lines and water is discharged from the outdoor unit. The outdoor unit should be positioned so that the water can drain
away or evaporate without causing any problems.
1. Reservoir cap
2. Empty condensate tank button
3. Prime water circuit button
4. Discharge air grille
5. Return air grille (air filter behind)
6. Cooling console
7. Compressor securing handwheel positioned centrally on the
underside of the base
8. Lifting handle
9. Control panel
10. Reservoir fill point
11. Reservoir cover

Advertisement

loading

Summary of Contents for London Cool MAC 500

  • Page 1 Locating the MAC 500 The MAC 500 indoor unit should be positioned in the room that requires air conditioning. It should be sited so that the air can circulate freely with no obstructions around the discharge air grille and/or the return grille. It must be positioned in an area where it is accessible to place the condensing unit outside taking into consideration the length of the flexible lines.
  • Page 2: Trouble Shooting

    The cleaning interval is determined by the area’s conditions. It is recommended to check the filter once a week Check the cooling water – The MAC 500 should not lose any cooling water during normal use. Some water may be •...
  • Page 3 4. If necessary, isolate the unit and check for water leaks inside the unit London Cool air conditioner rental and sales This document has been compiled in good faith, but no representation is made or warranty given (either express or implied) as...