Master & Slave With Timer - Elite access systems Sl-3000 series Installation Instructions Manual

Table of Contents

Advertisement

115 Volt
10
8
6
9
7
5
MASTER J2
1. Connect pin #1 of J2 Master to pin #1 of J2 Slave.
Connect pin #2 of J2 Master to pin #2 of J2 Slave.
Connect pin #6 of J2 Master to pin #8 of J2 Slave.
Connect pin #5 of J2 Master to pin #7 of J2 Slave.
2. Turn the timer pod, in the slave gate operator, all the way counter clockwise.
3. For time range automatic close adjustment, use Master timer only.
4. Caution! Do not shut off any of the two timers. Place the timer switch on "ON" position only.
For time range automatic close adjustment, use Master timer only.
10
MASTER AND SLAVE WITH TIMER
4
2
PLACE 4 LOW VOLTAGE WIRES
3
1
MASTER
ON
TIMER
60
OFF
BETWEEN OPERATORS
ON
0
OFF
10
8
9
7
SLAVE J2
SLAVE
TIMER
60
0
115 Volt
6
4
2
5
3
1

Advertisement

Table of Contents
loading

Table of Contents