DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow applications and may be converted for downflow appli-
cations.
These furnaces are designed for residential mobile home, man-
ufactured, or modular home installation. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category IV direct vent, sealed combustion
listed and may be vented either through side wall or roof appli-
cations using approved plastic combustion air and vent piping.
WARRANTY
15-year limited warranty on the heat exchanger.
2-year limited parts warranty.
FEATURES
• Easily applied in upflow or downflow installation with minimal
conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable operation.
• Low unit amp requirement for easy replacement application.
• All models are convertable to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with increased
dependability and reliability.
• 100% shut off main gas valve for extra safety.
• 4 speed, direct drive PSC motor.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary heat exchanger made of corrosion resistant
stainless steel materials.
• Timed on, adjustable off blower capability for maximum
comfort.
• Blower door safety switch.
• Solid removable bottom panel allows easy conversion.
• Airflow leakage less than 1% of nominal airflow at
ductblaster conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Protection included from air intake, exhaust vent, or
condensate blockage.
• Patent pending self priming internal condensate trap design
for easy installation.
• Venting applications - installed as a 2-pipe (sealed
combustion) using outdoor air for combustion.
• No special vent termination required.
• 1/4 turn knobs provided for easy door removal.
426499-BTG-C-0912

Advertisement

loading

Summary of Contents for Coleman MG9S060B12MP11

  • Page 1 426499-BTG-C-0912 DESCRIPTION TECHNICAL TECHNICAL These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in GUIDE GUIDE upflow applications and may be converted for downflow appli- cations.
  • Page 2 20” RETURN END SUPPLY END Cabinet & Duct Dimensions (Upflow configuration shown) Approximate Cabinet Dimensions (Inches) Nominal Cabinet Operating Weights Models Size MG9S060B12MP11 1200 17 1/2 16 3/8 13 1/4 MG9S080B12MP11 1200 17 1/2 16 3/8 14 3/4 MG9S080C16MP11 1600...
  • Page 3 426499-BTG-C-0912 FILTER PERFORMANCE CONDENSATE NEUTRALIZER KIT - Neutralizer cartridge has a 1/2" plastic tube fittings for installation in the drain line. Cal- The airflow capacity data published in the “Blower Perfor- cium carbonate refill media is also available from the Source 1 mance”...
  • Page 4 Ext. Static Pressure (in. H2O) High 1492 1442 1378 1325 1243 1176 1075 Medium High 1236 1201 1161 1139 1082 1011 MG9S060B12MP11 Medium Low High 1597 1537 1484 1435 1370 1286 1230 1155 1075 Medium High 1338 1307 1273 1223...

This manual is also suitable for:

Mg9s080b12mp11Mg9s100c16mp11Mg9s080c16mp11Mg9s100c20mp11Mg9s120d20mp11