Vornado IR400 Owner's Manual

Vornado IR400 Owner's Manual

Dual zone

Advertisement

model IR400
DUAL ZONE
INFRARED HEATER
OWNER'S GUIDE
GUÍA DEL PROPIETARIO
CALEFACTOR INFRARROJO
DE ZONA DUAL
READ AND SAVE
THESE INSTRUCTIONS
LEER Y GUARDAR
ESTAS INSTRUCCIONES
www.vornado.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IR400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vornado IR400

  • Page 1 IR400 DUAL ZONE INFRARED HEATER OWNER’S GUIDE GUÍA DEL PROPIETARIO CALEFACTOR INFRARROJO DE ZONA DUAL READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES www.vornado.com...
  • Page 2 PERFECT www.vornado.com 800.234.0604 help@vornado.com English...
  • Page 3: Table Of Contents

    CONTENTS Important Instructions ................ 4 Reset Heater ..................13 Whole Room vs. Heat Zone ..............8 Troubleshooting ................14 Safety Features ................... 9 Warranty .................... 15 Controls ..................... 10 Product Specifications ..............30 How To Use ..................11 Cleaning .................... 12 Español p.
  • Page 4: Important Instructions

    IMPORTANT INSTRUCTIONS WARNING – When using electrical appliances, basic precau- tions should always be followed to reduce the risk of fire, electric READ ALL INSTRUCTIONS BEFORE USING. shock and injury to persons, including the following: WARNING This owner’s guide and any additional inserts are considered part of Risk from Unintended Use and Handling.
  • Page 5 - Do Not use this heater on a circuit that has a variable speed - The IR400, like any other 1500-watt electric heater, draws up to device operating, such as a blender or variable speed fan. 12.5 amps of electric current. If using your IR400 on the Whole...
  • Page 6 IR400. in any manner. Do not use on soft surfaces, like a bed, where - Run the IR400 on Whole Room Low Heat mode. openings may become blocked. - Have your electrician add an additional circuit to your homes - A heater has hot and arcing or sparking parts inside.
  • Page 7: Save These Instructions

    If this equipment does cause harmful interference to radio or televi- sion reception, which can be determined by turning the equipment off and on, the user is encouraged to contact Vornado Consumer Service at 1-800-234-0604. SAVE THESE INSTRUCTIONS Please keep all documents for future reference and pass these docu- ments on, together with the product, to any future owner.
  • Page 8: Whole Room Vs. Heat Zone

    WHOLE ROOM VS. ZONE HEAT For the first time, you now have the choice between Whole Room Warmth OR a Personalized Zone Heat with the Vornado Dual Zone Infrared Heater. The IR400 has the ability to use Vornado’s signature Whole Room Heat circulation to deliver continuous, uniform heat to the entire room, or switch to a Personal Zone Heat for extra-warm heat just for you.
  • Page 9: Safety Features

    SAFETY FEATURES POWER CORD STORAGE COOL TOUCH CASE Safely store excess cord on the back Safe to touch, even on of heater. high heat setting. AUTOMATIC SAFETY SHUT OFF SYSTEM If airflow becomes blocked, power to the heater is shut off to prevent overheating.
  • Page 10: Controls

    CONTROLS The LED Display illuminates when powered on and as settings are adjusted, then dims after five seconds of inactivity. POWER INDICATOR LIGHT To indicate the heater is on, POWER ON/OFF ( ) the red light will illuminate. SET TEMPERATURE (-/+) WHOLE ROOM HEAT High (1500 watts), Low PERSONAL ZONE HEAT...
  • Page 11: How To Use

    HOW TO USE Before use, check appliance for visible damage. DO NOT USE THIS HEATER if there is evidence of damage. If any damage is found, contact Vornado Air LLC at 1-800-234-0604. 4. Press the power button ( ) and select Personal Zone Heat ) or Whole Room Heat ( ).
  • Page 12: Cleaning

    Because your heater moves a substantial amount of air, it will need regular cleaning. Cleaning the outside of the heater is recommended on a bi-weekly basis. If service is required, return your heater to Vornado (see WARRANTY for instructions). 1. Unplug your heater before cleaning.
  • Page 13: Storage

    4. Plug in the power cord and place heater in desired position. carton if available. This will prevent the heater from accu- 5. Press the power button on. Your Vornado Heater should now func- mulating dust overtime. tion normally and return to the last stored setting.
  • Page 14: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE AND SOLUTION The unit fails to power on. Unit is not plugged in. Plug power cord into electrical outlet. Household circuit breaker / ground fault interrupter has tripped or blown a fuse. Reset circuit breaker / ground fault interrupter, or replace fuse (See IMPORTANT INSTRUCTIONS).
  • Page 15: Warranty

    All technical information, data, and instructions for the installation, connec- Vornado Air LLC Attn: Warranty & Repair 415 East 13th Street Andover, KS 67002. For your tion, and operation contained in these instructions for use correspond to the latest avail- convenience, please have your model number and serial number when contacting able information at time of printing.
  • Page 16: Product Specifications

    PRODUCT SPECIFICATIONS IR400 MODEL 120V~ VOLTAGE 1500W WATTAGE AMPERAGE 12.5A UNIT DIMENSIONS 12.75” (32.4 CM.) x 9.35” (23.8 CM.) x 11.70” (29.7 CM.) ESPECIFICACIONES DEL PRODUCTO IR400 MODELO VOLTAJE 120V~ VATIAJE 1500W AMPERAJE 12.5A DIMENSIONES DE LA UNIDAD 12.75” (32.4 CM.) x 9.35” (23.8 CM.) x 11.70” (29.7 CM.)
  • Page 17 Vornado Air, LLC 415 East 13th Street, Andover, Kansas 67002 800.234.0604 | www.vornado.com CL3-0394 R-, V00...

Table of Contents